Whole-air relaxed eddy accumulation for the measurement of isotope and trace-gas fluxes
Full text
UNIVERSITÄT BAYREUTH Abteilung Mikrometeorologie Whole-air relaxed eddy accumulation for the measurement of isotope and trace-gas fluxes by J. Ruppert, M. Riederer, W. A. Brand and T. Foken Arbeitsergebnisse Nr. 51 Bayreuth, Juni 2012
2 Arbeitsergebnisse, Universität Bayreuth, Abt. Mikrometeorologie, Print, ISSN 1614-8916 Arbeitsergebnisse, Universität Bayreuth, Abt. Mikrometeorologie, Internet, ISSN 1614-8924 http://opus.ub.uni-bayreuth.de/schriftenreihen_ebene2.php?sr_id=4&la=de Eigenverlag: Universität Bayreuth, Abt. Mikrometeorologie Vervielfältigung: Druckerei der Universität Bayreuth Herausgeber: Prof. Dr. Thomas Foken Monographien - Einzelexemplare in Bayerischen Bibliotheken Universität Bayreuth, Abteilung Mikrometeorologie D-95440 Bayreuth Die Verantwortung über den Inhalt liegt beim Autor.
3 Editorial remarks This report was part of the PhD-Thesis by J. Ruppert (2009). The paper was not accepted because of the availability of measuring systems based on tunable lasers. Nevertheless the method has significant benefits in relation to the accuracy of the measured fluxes even when the handling is not simple. Therefore, the system was again used in the ongoing PhD-study by M. Riederer and updated in some details. The following report bases on J. Ruppert’s paper with some additional remarks and updates by M. Riederer. Th. Foken Whole-air relaxed eddy accumulation for the measurement of isotope and trace-gas fluxes J. Ruppert 1,2 , M. Riederer 1 , W. A. Brand 3 , T. Foken 1 1 Department of Micrometeorology, University of Bayreuth, Germany 2 now: Research Institute of the Cement Industry, Verein Deutscher Zementwerke, Düsseldorf, Germany 3 Max Planck Institute for Biogeochemistry, Jena, Germany Abstract Measuring the isotopic composition of trace gas fluxes can provide additional information on ecosystem gas exchange, when ecosystem processes, like assimilation, discriminate against heavier isotopes. In the case of CO 2 exchange, different mass-balances for bulk CO 2 and its 13 CO 2 or CO 18 O isotopes can be used to separate respiration from photosynthetic assimilation. Up to now, detectors for direct isotope measurements in the field lack the precision needed for fast eddy covariance (EC) flux measurements. The collection of updraft and downdraft whole-air samples using the relaxed eddy accumulation technique (REA) allows simultaneously determining trace gas concentrations and isotope ratios by high precision laboratory analysis. At the same time whole-air REA relaxes several of the technical problems related to REA sampling on traps. In tests using air from a tank the complete whole-air REA sampling system and its foil balloon bag reservoirs showed no signs of contamination after cleaning. The standard deviations of δ 13 C and δ 18 O isotope ratios were only slightly higher than the precision specified for the laboratory analysis procedure. First experiment results showed that isotopic differences (updrafts−downdrafts) were large enough to yield signal to noise ratios greater than five when applying hyperbolic deadbands during REA sampling (HREA). The performance of the instrument and the HREA sampling method are investigated by simulation of the sampling process for bulk CO 2 , which serves as proxy scalar. Measurements by whole-air HREA in combination with high precision isotope analysis can quantify the isofluxes of 13 CO 2 and CO 18 O. Furthermore, additional information is collected on the scalar correlation of bulk CO 2 and its stable isotopes, which represents the relatively short timescale of updrafts and downdrafts in the turbulent exchange above an ecosystem. This information is essential to check the scalar similarity assumptions made in the HREA and EC/flask method for the quantification of isofluxes.
4 1. Introduction In recent years, a special interest was to quantify the isotopic composition of CO 2 flux densities above different ecosystems (Bowling et al., 2003a; Ehleringer et al., 2002; Yakir and da S. L. Sternberg, 2000). Such measurements provide means for identifying the individual contributions of sources and sinks with different isotopic signature to the CO 2 net ecosystem exchange (NEE) and the rate of internal recycling of CO 2 , e.g. in the canopy space of forests (Lloyd and Farquhar, 1994; Lloyd et al., 1996; Yakir and Wang, 1996). Two different mass-balances for bulk CO 2 and its isotopes can be used to separate respiration from assimilation, which discriminates against 13 CO 2 and CO 18 O (Bowling et al., 2001; Wichura et al., 2004; Wichura, 2009). Different eddy sampling methods like relaxed eddy accumulation (REA, Businger and Oncley, 1990) are commonly used to measure trace gas fluxes in the boundary layer when fast high precision chemical sensors are not available for eddy covariance (EC) flux measurements. Eddy sampling methods are passive in the sense that they do not modify the turbulent gas exchange of the ecosystem. Therefore such measurements are complementary to measurements with enclosures e.g. on individual parts of the ecosystem and can be used for their validation. Measurements of the turbulent exchange above an ecosystem provide information with a spatial integration that can close a gap of scale between isotope studies at leaf or branch scale and atmospheric isotope studies and large scale modeling approaches (Canadell et al., 2000; Kaplan et al., 2002; Yakir and da S. L. Sternberg, 2000). This is especially important for the investigation of carbon budgets of forests, because in tall vegetation complex gas exchange processes exist. The ability to analyze the isotopic signature of the turbulent exchange is mainly limited by the measurement uncertainty regarding the CO 2 isotope ratios at small differences of bulk CO 2 mixing ratios (Bowling et al., 1999a; Bowling et al., 1999b; Bowling et al., 2003b; Zobitz et al., 2006). Most studies on isotope flux measurements above the canopy focus on the evaluation of the 13 C-isotope signatures. In general, the difference of isotope signatures in the CO 2 exchange during the day is expected to be larger for 18 O-isotopes, because the 18 O-isotope signature of CO 2 can equilibrate with 18 Odepleted soil water and 18 O-enriched leaf water pools (Yakir and da S. L. Sternberg, 2000). CO 18 O isotope fluxes could therefore yield more independent information on assimilation and respiration. However, measurement results presented by Bowling et al. (1999a) were less uniform, which might reflect higher temporal and spatial variability of the water pools. The aim of this study is to present a method for the measurement of 13 CO 2 and CO 18 O isotope fluxes based on the hyperbolic relaxed eddy accumulation method (HREA) and whole-air sampling. The application of the hyperbolic sampling criteria maximizes scalar concentration differences (Bowling et al., 1999b). Whole-air sampling allows subsequent high precision isotope analysis in a laboratory directly from the accumulated updraft and downdraft air samples (Bowling et al., 2003a). With the construction of a new sampling system we aimed at further improving the accuracy of isotope sampling especially for 18 O isotopes. Sample volumes were increased in order to also allow direct and precise analysis of the corresponding bulk CO 2 mixing ratios. The integrity of isotope samples and sampling accuracy was thoroughly tested in the laboratory and in the field by comparison with independent measurements above a spruce forest during the experiment WALDATEM-2003 and above extensively managed grassland during the experiment FORKAST-TP5 in 2010. The combined information of CO 2 isotope ratios and mixing ratios in updraft and downdraft air samples is used to analyze the scalar correlation, which is a basic assumption in the HREA and EC/flask methods (Bowling et al., 2003a). Based on the measured bulk CO 2 , the HREA sampling pro-
5 cedure and flux determination method are validated as requested by Bowling et al. (1999a) and Kramm et al. (1999). The methodological performance of HREA is investigated by simulation of the sampling process. However, the effective sampling efficiencies determined from measured bulk CO 2 data are taken into account for the determination of turbulent isofluxes. 2. Theory In the conditional sampling or relaxed eddy accumulation method (REA) (Businger and Oncley, 1990) the turbulent flux is determined from the concentration difference measured in updraft and downdraft air samples. This concentration difference is scaled with the intensity of turbulent vertical mixing measured by the standard deviation of the vertical wind speed σ w based on the assumption of flux-variance similarity. Because air sampling is not proportional to the vertical wind speed, it is referred to as relaxed sampling. Consequently, REA is an indirect method for flux measurements. It relies on a parameterization in which the so called b-factor is determined from a second scalar quantity (proxy scalar) which shows similarity in its atmospheric transport (scalar similarity, (Ruppert et al., 2006b; Wyngaard and Moeng, 1992)) and for which the fluctuations of its concentration can be measured in the field with high temporal resolution: ( ) c w F b σc c ↑ ↓ = − . (1) c F is the turbulent flux of the scalar c. c ↑ and c ↓ are the average scalar concentrations respectively in updraft and downdraft air samples expressed as dry air mixing ratios. For the proxy scalar normally c F is determined by eddy covariance (EC) measurements ( c F w' c' = ), where w' and c' are the fluctuations of the vertical wind speed w and scalar concentration c around their average values. The over bar denotes Reynolds averaging. The proportionality factor b can then be determined for the proxy scalar by rearranging (1) either based on (i) simulation of REA sampling on high frequency scalar time series and its resulting concentration difference c c ↑ ↓ − or based on (ii) measured concentration difference from real REA air sampling for the proxy scalar: ( ) w w' c' b σc c ↑ ↓ =− (2) Many studies demonstrate the relative stability of average b-factors in unstable and moderately stable conditions (Ammann and Meixner, 2002; Baker et al., 1992; Beverland et al., 1996a; Foken et al., 1995). Nevertheless, significant variability of b-factors for individual 30 min periods is observed, and different factors are discussed (Gao, 1995; Guenther et al., 1996; Oncley et al., 1993; Pattey et al., 1993; Ruppert et al., 2006b). Several studies point out, that skewness in the joint frequency distribution (JFD) of w' and c' and structures in the turbulent exchange are causing changes in b-factors (Fotiadi et al., 2005; Katul et al., 1996; Milne et al., 2001; Ruppert et al., 2006b). The study by Ruppert et al. (2006b) attributes observed variation in the scalar exchange to events at time scales >60 s. This limits the use of a unique b-factor for all times and asks for the determination of individual bfactors for each sampling period. Under the assumption of scalar similarity, the b-factor determined
6 for a proxy scalar by (2) is used to derive the turbulent flux of the scalar of interest from its measured average concentration difference between updraft and downdraft REA samples c c ↑ ↓ − by solving (1). Application of a wind deadband for small vertical wind speeds, in which no samples are taken, increases the concentration difference between the updraft and downdraft air accumulation reservoirs and thereby the certainty of the flux measurement, especially if chemical sensor resolution is a limiting factor (Businger and Delany, 1990; Delany et al., 1991). At the same time, the b-factor decreases with the size of the deadband. The wind deadband size H w is normally defined in reference to the normalized vertical wind speed fluctuations: w w σ 'H w≤. (3) In the hyperbolic relaxed eddy accumulation method (HREA) the deadband rejects not only samples with small fluctuations of the vertical wind speed w' but also samples with small deviations from the mean scalar concentration, which further increases the concentration difference c c ↑ ↓ − (Bowling et al., 1999b; Bowling et al., 2003a): h cw σσ '' H cw ≤. (4) The hyperbolic deadband with the size H h must be determined online from a proxy scalar measured with high temporal resolution, which again assumes scalar similarity. A deadband reduces the frequency of valve switching during sampling and at the same time, the number of samples used for flux calculation. It also reduce the sensitivity of REA methods to uncertain definition of the mean vertical wind speed w needed for segregating samples in the up and down reservoirs (Businger and Oncley, 1990; Pattey et al., 1993). Details on the sampling method and procedures used in this study are described in Section 3. A comparison of general characteristics of eddy sampling methods like REA and HREA and different sources of error for flux determination are presented in a paper by Ruppert et al. (2002).
7 3. Methods and Material The design of the whole-air REA system goes back to the principles ideas for conditional sampling of trace gases (Businger and Oncley, 1990; Delany et al., 1991; Desjardins, 1977; Oncley et al., 1993; Pattey et al., 1993) and is based on a design presented by Bowling et al. (2003a) in which foil balloon bags serve as intermediate storage for updraft and downdraft air samples at ambient pressure. 3.1. Scalar similarity The determination of b-factors in the REA method and the online definition of a hyperbolic deadband (i.e. in the HREA method) requires the selection of a proxy scalar, which shows good scalar similarity with the scalars of interest. For this study the bulk CO 2 density signal (ρ CO2 ) of an open path gas analyzer was selected as proxy scalar for the estimation of the scalar intensity of 13 C and 18 O isotopes 1 of CO 2 . The assumption is, that bulk CO 2 density shows sufficient scalar similarity with the unknown fast fluctuations of the CO 2 isotopic composition. A detailed discussion of the effects of scalar similarity in REA flux measurements is presented by Ruppert et al. (2006b) and in the diploma thesis of Hübner (2010). We are confident, that the assumption is justified at least for the efficient selection of the strong upand downdrafts by a hyperbolic deadband, as all CO 2 isotope turbulent exchange is part of the bulk CO 2 turbulent exchange. Also, linear relationships between the δ 13 C isotope ratio and bulk CO 2 mixing ratio of whole-air samples collected at timescales down to 500 ms and of REA samples are reported by Bowling et al. (1999a; 2001). Nevertheless, if considering the location of sources and sinks in the ecosystem individually for bulk CO 2 , 13 CO 2 and CO 18 O, some difference in the scalar exchange should be expected, which might also affect scalar similarity. Less scalar similarity would introduce some error in HREA flux results with a tendency for underestimating the flux (Ruppert et al., 2006b). The assumption of scalar similarity made here is therefore tested by investigating the δ 13 C/CO 2 and δ 18 O/CO 2 relations (Section 4.4). The following sections describe the implemented online turbulence data analysis, the HREA sampling procedures, the whole-air REA system design for high precision isotope and trace-gas sampling and sample analysis. 3.2. Axis rotation and hyperbolic deadband definition A three-dimensional planar fit rotation matrix was determined based on 1 month of wind velocity data from the sonic anemometer used for eddy covariance and REA sampling. It indicated good horizontal orientation of the sonic anemometer and that only minor planar-fit corrections were necessary for the vertical wind speed. The determination of the turbulent CO 2 flux densities from EC measurements was performed with the TK2 software package (Mauder and Foken, 2004) and common corrections and quality control measures were applied as outlined by Ruppert et al. (2006a) including a WPL-correction for density 1 13 C and 18 O isotope ratios in this study refer to the isotope composition of CO 2 , i.e. the ratio of 13 CO 2 or CO 18 O to bulk CO 2 . The isotope ratio is expressed in δ-notation. All δ 13 C and δ 18 O values are reported relative to 13 C and 18 O isotopic abundances in the international VPDB (Vienna Pee Dee Belemnite) and VPDB-CO 2 standards respectively (CG99 scale, see details in (Werner et al., 2001) and (Werner and Brand, 2001)): δ 13 C=[[( 13 C/ 12 C) sample –( 13 C/ 12 C) VPDB ]/( 13 C/ 12 C) VPDB ]· 1000 (‰ VPDB). δ 18 O=[[( 18 O/ 16 O) sample –( 18 O/ 16 O) VPDB-CO2 ]/( 18 O/ 16 O) VPDB-CO2 ]· 1000 (‰ VPDB-CO 2 ).
8 fluctuations (Webb et al., 1980) and a planar-fit rotation (Wilczak et al., 2001) with a vertical wind speed offset correction of 0.032 m. The problem of axis rotation for REA was raised by Beverland et al. (1996b) and Moncrieff et al. (1998). We addressed this issue by applying the previously determined planar-fit correction to the vertical wind component online during HREA sampling and were thereby able to correct the vertical wind speed offset. The coordinate rotation of the planar-fit correction (<3°) was applied slightly incorrect to the online data used during HREA sampling. This was due to an unidentified azimuth rotation of 120° between the sonic anemometer raw online data and stored data. However, simulations showed, that this had only minor influence on the updraft and downdraft HREA sample segregation under the conditions of the WALDATEM-2003 experiment. The resulting relative error of the HREA concentration difference due to the erroneous online planar-fit rotation was –2(±3)%. This indicates a small underestimation of the concentration difference on average, i.e. slightly reduced efficiency in sampling the maximum concentration difference. This equally applies to the proxy scalar and the scalar of interest. Therefore, the turbulent flux densities will hardly be altered, if they are calculated from measured effective b-factors for the proxy scalar like in this study. In general, the problem of axis rotation and definition of the vertical wind vector for REA and HREA can be addressed. Like described above the planar-fit correction method can be applied as detailed axis rotation procedures for the correction of the vertical wind speed w based on fast online analysis of the 3D wind data with a computer. This can be done without time lags from filter functions as asked for by Moncrieff et al. (1998) as long as (i) a 3D sonic anemometer is installed long enough before REA sampling to collect a statistically meaningful amount of wind data specific to the site, sonic anemometer and its orientation and (ii) the anemometer orientation remains unchanged for REA sampling. Both criteria can easily be met when REA sampling is performed at sites with permanently installed eddy covariance measurement systems, e.g. at FLUXNET sites. For the online definition of the hyperbolic deadband during REA sampling according to (4) the vertical wind speed fluctuations w' were determined from the 3D wind vector after applying the planar-fit correction. The standard deviation of the vertical wind speed as well as the average and standard deviation of the CO 2 density were continuously recalculated from the most recent 6 min of data applying a linear weighting function by which the newest data was rated three times more important than the oldest data. 3.3. Whole-air REA sampling system and sampling procedure From close to the measurement path of a sonic anemometer air is sampled through a 1 µm filter and 5 m of Dekabon tubing with polyethylene as inner wall material with a total flow rate of 6.6 L min −1 , which assures predominantly turbulent flow (Reynolds number= 2433) in the inlet tube. Plumbing in the system consisted of stainless steel tubing and fittings. All steel and glass material in the system was thoroughly cleaned before assembling by threefold rinsing with Acetone:Hexane 1:1 (nanograde) and subsequent heating. Connection to the REA system and to the glass flasks is made using quick connectors and ultra-torr glass connectors. Viton® only is used as seal material also in membrane pumps and valves. The air stream is splitted into a bypass and a sub-sample of 3 L min −1 (Figure 1a). Only the sub-sample is used for REA sampling of updrafts and downdrafts. Constant flow rates (σ ≤0.5%) with minimum pressure drop as asked for by Bowling et al. (1998) and Moncrieff et al. (1998) are achieved by using low pressure drop flow meters in combination with pulse-width pump motor drivers for the adjustment of constant pump performance, instead of flow controllers. A Nafion® gas-dryer is used for pre-drying of the sample air. Two three-way valves (V1, V2) direct the
9 sample into the vent (deadband) or the bag 1 or bag 2 reservoirs according to the sign of the vertical wind speed and the size of the deadband (updraft, downdraft). During field experiments the definition of bag 1 and bag 2 as reservoirs for REA updraft or downdraft samples was switched after each sampling interval in order to minimize any systematic influence of one sampling path. A third nonoperating valve of the same kind is installed to assure the same flow restriction on all three flow paths. The time lag (7 ms) resulting from the separation of the sampling valves V1 and V2 and the selected flow rate and the valve response times (10-20 ms) are small enough in relation to a desired sampling frequency of 10 Hz (100 ms). In order to allow for larger sample volumes, each bag reservoir consists of two 45 cm diameter Mylar® foil balloons, which are equipped with stainless steel filling tubes, partially perforated, inserted through the foil valve of the balloons and joined with a T-fitting (not shown in Figure 1a and 1b). An airtight seal was achieved by wrapping strong rubber band around the filling tube and foil valve. After REA sampling and before filling into 1 L glass flasks with PCTFE stopcocks the air from the reservoirs is further dried by passing through drying traps filled with magnesium perchlorate granulate (Mg(ClO 4 ) 2 ). Backpressure valves at the system outlet constantly maintain +500 hPa over ambient pressure in the drying traps and glass flasks in order to minimize potential fractionation by adsorption/desorption processes at the relatively large surfaces of the granulate and flasks. The dead volume of the bag reservoirs, which cannot be removed by pumping, is about 20 mL. Nevertheless, all old sample in the reservoirs is removed effectively (dilution >>10000:1) prior to REA sampling by flushing the bag reservoirs two times with 10 L of dried air from sampling height through the flushing unit and emptying via the flask-fill units. During a third flushing cycle the bag reservoirs and the two flask-fill units are then conditioned with dried air from sampling height. The bag reservoirs are emptied and conditioning air remains in the drying traps and glass flasks during the next 3040 min REA sampling procedure. Normally about 10 to 15 L of updraft and downdraft air were collected within 30-40 min of REA sampling with a hyperbolic deadband of H h =1.0. This allowed flushing the 1 L glass flasks with 6 to 10-fold volume of sample at +500 hPa overpressure. The filling procedure is stopped shortly before one of the bag reservoirs is emptied by closing actuated two-way valves on both sides of the glass flasks and then manually closing the stopcocks of the flasks. Refer to the Table 1 for details on individual system components. The complete sampling procedure is controlled by the software ‘ATEM’ (Atmospheric Turbulence Exchange Measurements, (Ruppert, 2005)), which allows online monitoring and automated detailed documentation of each sampling procedure. This software also performs the required online analysis of wind and scalar data during REA sampling for the definition of the hyperbolic deadband and corresponding segregation of updraft and downdraft air samples. 3.4. Changes in the whole-air REA sampling system in 2010 In order to avoid overfilling of the balloons larger sample volumes were installed. Two balloons (45 cm diameter) of each upand downdraft were replaced by one balloon each with 90 cm diameter. Thereby, the volume was enlarged by 28 L to 50 L. Also the risk of leakages in the balloons was reduced, because the well development can be supervised much easier with fewer balloons. In addition to that, balloon holders were constructed that secured an evenly folding of the balloons during filling and well development. The balloon is fixed to a massive circular steel ring - attached to the REA housing - with binder clips and elastic straps that it is always evenly mounted and does not fold. In field experiments the researcher must pay attention to arrange the balloons with the wind direction not to create a sail.
16 4. Results and Discussion 4.1. Foil balloon bag tests The importance of the material selection and treatment for air sample isotope analysis is highlighted by tests results presented by Schauer et al. (2003) in which heated stainless steel tubing, Viton® seals and polyethylene (PE) were found not to contaminate CO 2 isotope samples. The isotopic integrity regarding δ 13 C of whole-air samples during storage of up to 60 min in Mylar® foil balloon bags with PE as inner wall material was demonstrated by Bowling et al. (2003a). However, a bias was found for residence times longer than 60 min and for δ 18 O. We therefore performed similar tests with the same kind of foil balloon bags. Air sampled from one pressurized air tank was analyzed after varying residence time in the balloon bags by high precision IRMS. A first test with brand new balloons flushed three times with air from the tank showed significant contamination of the air samples with heavier isotopes (Figure 2) depending on time after flushing. The contamination presumably is the result of the release of substances with fossil origin from the balloon inner wall material PE. For a second test, we treated the balloons by flushing them for about 4 days with nitrogen and dried air and by exposing them to intense direct sunlight. Afterwards, 9 balloon bags were first filled and emptied three times in the morning of the second test and then filled consecutively with air form a tank during the day, allowing different sample residence times up to 2 h before analysis. Only after the treatment, the balloon bags lacked signs of significant contamination (Figure 3, (WALDATEM-2003 (a) and (b), FORKAST-2010 (c). The standard deviation for both δ 13 C and δ 18 O isotope ratios from the 9 samples were acceptably low and the average value of the balloon bag samples compared well with an air sample taken directly from the tank and stored in a glass flask. These results demonstrate the general suitability of foil balloon bags for both 13 C and 18 O isotope air sampling and intermediate storage, which is normally restricted to 30-40 min in REA. δ13C(‰VPDB) -9.00 -8.00 -7.00 -6.00 -5.00 -4.00 -3.00 0 2 4 6 8 δ18O(‰VPDB-CO2) -6.50 -6.00 -5.50 -5.00 -4.50 -4.00 timeafterflushing(h) a) b) Figure 2. Foil balloon bag test for 13 C (a) and 18 O (b) isotope sampling before cleaning. The symbols represent the measured isotope ratios in 6 individual balloon bags. Each bag was flushed 3 times with sample air from one air tank on its first usage. Dashed lines indicate the progressive contamination of the air with heavier isotopes after the flushing procedure.
17 air tank δ13C(‰VPDB) -8.80 -8.75 -8.70 -8.65 -8.60 all samples 0:00 0:30 1:00 1:30 2:00 δ18O(‰VPDB-CO2) -0.75 -0.70 -0.65 -0.60 -0.55 -0.50 -0.45 σ= 0.019 σ= 0.035 sampleresidencetimeinballoonbag(h) air tank all samples a) b) Figure 3. Foil balloon bag test for 13 C (a) and 18 O (b) isotope sampling after bag cleaning (WALDATEM-2003 (a) and (b), FORKAST-2010 (c). Symbols in the leftmost section of the figure represent isotope ratios measured in air sampled from one tank after different residence times in 9 different balloon bags. Error bars indicate the standard deviation of up to 12 repeated measurements on the same air sample, which form the basis for the specification of its isotope ratio with high precision. Dashed lines and the solid symbol in the right section of the figure represent the average isotope ratio measured in the 9 balloon bags. The corresponding error bar indicates the standard deviation of the 9 specified isotope ratios from the balloon bag samples. As reference, the rightmost section of the figure shows the isotopic ratio of air sampled from the air tank into a glass flask without residence in a balloon bag. Note the difference in scales when comparing to Figure 2. 4.2. Whole-air REA system tests We repeated the tests with the complete whole-air REA system described in Section 3. Beforehand, small leaks in the REA system were located by performing leak tests with high-vacuum and removed. In a third test for isotopic integrity (no figure), samples were directed through different parts of the system (REA sampling unit, flushing unit, flask fill unit, see Figure 1a). Small standard deviations of δ 13 C (0.022‰) and δ 18 O (0.021‰) isotopic ratios in 15 samples assured, that the surfaces of other materials in the system which contact the sample (glass, stainless steel, aluminum, Viton® seals, Nafion®, Mg(ClO 4 ) 2 granulate) were clean and no source of sample contamination. In a fourth test we operated the complete whole-air REA system in the same way as for field sampling with automated sampling procedures after threefold flushing of the balloon bags, drying traps and glass flasks (see Section 3.3) but by drawing sample air and air for flushing and conditioning from a tank. The samples were stored for about 30 min in the balloon bags and filled into glass flasks for later analysis. The standard deviation of δ 13 C (0.014‰) and δ 18 O (0.019‰) in 19 samples were close to the measurement precision of the mass spectrometer and the average isotopic ratios matched well with an air sample from the tank stored in a glass flask (Figure 4). Before producing the sample J585, the complete REA system, balloon bags and glass flasks were contaminated with room air (dotted line), which presumably had isotopic ratios depleted by human c)
18 breath compared to the pressurized air tank. The isotopic ratios of samples produced afterwards show no systematic deviation from the average, which indicates, that the threefold flushing procedure is effective in removing old sample air. The test results with the treated balloon bags (9 samples) and the complete whole-air REA system with the automated field sampling procedure (19 samples) demonstrate the isotopic integrity of samples taken with the system and the systems suitability for high precision isotope sampling. Nevertheless, the sample air residence time in the balloon bags should be restricted to the minimum needed for REA sampling (30-40 min) and the samples should then be transferred to glass flasks for the transport from the field to the laboratory. The whole air REA system test in 2010 was accomplished in a similar way. The contamination with room air in the beginning of the test becomes visible in the J1 samples by slightly higher δ 13 C values (Figure 4c). The normalization of the values J2 (and all following values) proofs, that the system is no longer contaminated after only one flushing process. all samples δ13C(‰VPDB) -8.80 -8.75 -8.70 -8.65 -8.60 J401 J403 J404 J405 J406 J407 J408 J409 J410 J411 J412 J413 J414 roomair J585 J586 J587 J588 J589 J415 δ18O(‰VPDB-CO2) -0.75 -0.70 -0.65 -0.60 -0.55 -0.50 -0.45 σ= 0.014 σ= 0.019 air tank samplesinchronologicalorder air tank all samples a) b) Figure 4. Test of the complete whole-air REA system for 13 C (a) and 18 O (b) isotope sampling cleaning (a) and (b) WALDATEM-2003, (c) FORKAST-2010). The usage of the symbols and lines follows the logic of Figure 3. Air from the tank was used for threefold flushing and directed through the REA sampling system, stored in the balloon bags and sampled into glass flasks in the same manner as required for REA sampling in the field. Subsequently, the 13 C and 18 O isotope ratios of CO 2 sampled into the glass flasks were measured. c)
19 4.3. HREA simulation and b-factors In order to check the efficiency of the updraft and downdraft sample segregation HREA sampling was simulated for each sampling interval using the actual valve switching record from the field experiments to segregate and virtually accumulate updraft and downdraft samples of the µ CO2 time series determined by (5). The simulated average updraft and downdraft mixing ratios are compared to average updraft and downdraft CO 2 mixing ratios measured in the whole-air samples in Figure 5. The least square linear regression for updraft and downdraft samples is well defined (R 2 =0.93) and results in a slope very close to one. This is a proof for correct instrument performance regarding the HREA sample segregation and accumulation process. The average offset of the measured values of +0.26 µmol mol −1 indicates good calibration of field instruments. Csimulation(µmolmol-1) 360 365 370 Cmeasured(µmolmol-1) 360 365 370 R2=0.93 Figure 5. Measured updraft and downdraft CO 2 mixing ratios in HREA whole-air samples plotted against CO 2 mixing ratios from simulation of HREA sampling based on the EC CO 2 time series (updraft solid and downdraft unfilled triangles) with their least square linear regression (line). Effective b-factors were determined from the measured updraft and downdraft CO 2 mixing ratio difference C ↑ ¯¯– C ↓ ¯¯ and the turbulent CO 2 flux density measured by EC according to (2). The effective bfactors can be compared to b-factors derived from the simulated mixing ratio differences (Figure 6). The simulated b-factors are very sensitive to the applied density correction (5), because of small mixing ratio differences relative to the absolute values of the mixing ratio. Simulations with simplified density corrections for the CO 2 mixing ratio data resulted in significant mismatches between the measured and simulated updraft and downdraft absolute CO 2 mixing ratios and consequently less correlation between measured and simulated b-factors. Both measured and simulated values of the b-factors show the variability that must be expected for HREA as well as for REA from the skewness in the JFD of the vertical wind speed and the scalar and from sampling effects which depend on the eddy reversal frequency (Baker et al., 1992). Like in other studies, which compare measured effective b-factors to simulated b-factors (Baker et al., 1992; Beverland et al., 1996b; McInnes et al., 1998), we find, that simulated values tend to underestimate measured values especially at higher b-factors. High b-factors were related to high turbulent flux density (R 2 =0.42) and reduced sampling efficiency, (R 2 =0.78), i.e. sampled concentration difference per turbulent flux density. The observed underestimation is the result of some inefficiency of the physical sampling process in separating updraft and downdraft samples compared to the virtual ‘digital’ sampling in HREA simulations (Baker et al., 1992; Beverland et al., 1996b; Lenschow and Raupach, 1991;
20 Massman, 1991; McInnes et al., 1998; Moncrieff et al., 1998). Measured effective b-factors resulting from the real physical sampling process integrate such deficiencies. In order to calculate REA turbulent flux densities from measured concentration differences by (1), measured effective b-factors should therefore be preferred in comparison to simulated b-factors. Virtual sampling results in a slightly higher concentration differences and consequently lower simulated b-factors according to (2). Simulated b-factors therefore require validation when used to replace effective b-factors that could not be measured, and an instrument and experiment specific correction needs to be found (Beverland et al., 1996a; McInnes et al., 1998), e.g. based on a least square linear regression function like shown in Figure 6. The overestimation of concentration differences from virtual ‘digital’ sampling of a proxy scalar in REA simulations evaluated for the b-factors without correction according to (2) can cause systematic underestimation of flux densities according to (1). The size of the residuals of the measured b-factors in Figure 6, quantified with 0.03 by the corresponding standard error, related to their range of absolute values of 0.15 to 0.35 provides an estimate of the average uncertainty of CO 2 fluxes measured by HREA with a hyperbolic deadband of H h =1.0 of about 10 to 20%. This quantifies the measurement uncertainty of the sampling system and method in reference to EC flux measurements for a component for which sufficient analytical precision is available during sample analysis (signal/noise ratio >10, Section 4.4). bCO2simulation 0.1 0.2 0.3 0.4 bCO2measured 0.1 0.2 0.3 0.4 R2=0.74 Figure 6. Effective b-factors derived from measured CO 2 mixing ratios in HREA whole-air samples in relation to simulated b-factors (circles) and their least square linear regression (line). More information about HREA simulations and b-factors, i.e. diurnal cycles of b, determined with various proxy scalars, is presented by Hübner (2010). There also the effects of potentially wrong bfactors on the REA-flux were evaluated. 4.4. Maximum concentration difference by HREA for isotope analysis The application of REA with hyperbolic deadbands, i.e. the HREA method (Bowling et al., 1999b), is intended to maximize the concentration difference of the scalar of interest, so that it can be resolved with sufficient precision by laboratory analysis. Simulations of REA (H w =0.6) and HREA (H h =1.0) with the WALDATEM-2003 data showed a concentration difference increase by a factor of 1.78 (Table 2), which is comparable to the factor of 1.84 derived from results presented by Bowling et al. (1999b). The factor reduces to 1.73 for the WALDATEM-2003 data or 1.65 in the work of Ruppert et al. (2006b), if imperfect scalar similarity between the scalar of interest and the proxy scalar is considered. However, all factors reported above are the result of simulations with an ideal definition of the hyperbolic deadband based on scalar data from the complete sampling interval (lines in Figure 7).
21 w(ms-1) -2 -1 0 1 2 C(µmolmol-1) 355 360 365 ↓ c ↑ c Figure 7. Plot of the effective hyperbolic sample selection for a 30 min sampling interval (dots) regarding vertical wind speed w and the open path CO 2 mixing ratio data C from the WALDATEM-2003 experiment, day of the year 188, 12:0012:30. The sample selection is based on the original HREA valve switching record. Both axes are scaled to the 30 min average ±4 standard deviations. The solid lines indicate the ideal hyperbolic deadband with the size H h =1.0 in respect to the 30 min statistics. The dashed lines indicate the average CO 2 mixing ratios of updraft (c ↑ ¯¯: w>0) and downdraft (c ↓ ¯¯: w<0) air samples, resulting from the effective hyperbolic sample selection. During the real sampling process, only historic scalar data is available. The mean scalar value is defined based on a filter function and the center of the hyperbolic deadband moves up and down along the scalar axis. This leads to less rigorous rejection of samples with average scalar values (see dots close to the center of Figure 7). Consequently, the average scalar concentration difference between updrafts and downdrafts is slightly decreased, e.g. the CO 2 mixing ratio difference C ↑ ¯¯– C ↓ ¯¯ in Figure 7. The application of a wind-deadband (REA) instead of a hyperbolic deadband (HREA) would incorporate even more air with average CO 2 mixing ratios (e.g. around 360 µmol mol −1 in Figure 7) in updraft and downdraft air samples and thereby further decrease the mixing ratio difference. Simulations based on the recorded valve switching from the WALDATEM-2003 experiment showed, that the realistic concentration difference increase between REA (H w =0.6) and HREA (H h =1.0) is only 1.63 (Table 2). The corresponding expected CO 2 mixing ratio difference from HREA simulations based on the effective sample segregation during the experiment with a hyperbolic deadband of H h =1.0 is 2.4(±0.5) µmol mol −1 . The observed mixing ratio differences were only slightly smaller, (2.3(±0.6) µmol mol −1 , Table 2, Figure 8a), reflecting also the physical air sampling effects discussed in Section 4.4. However, these also affect REA sampling with a wind-deadband and an effective relative concentration difference increase close to 1.63 can be assumed.
22 CO2(µmolmol-1) -4 -3 -2 -1 0 δ13C(‰VPDB) 0.00 0.05 0.10 0.15 0.20 dayoftheyear(CET) δ18O(‰VPDB-CO2) -0.1 0.0 0.1 0.2 0.3 188 189 190 c) b) a) 5 σ 10 σ 5 σ 10 σ Figure 8. CO 2 mixing ratio differences (a) and 13 C (b) and 18 O (c) isotope ratio differences in updraft and downdraft REA air samples (solid diamonds). 18 O isotope ratio differences presumably influenced by incomplete drying out of the period marked with a gray bar are indicated as unfilled diamonds. Dotted lines indicate the fivefold and tenfold standard deviations specified in Section 4.2 and Figure 4 in order to assess the measurement precision for the isotope samples. We avoided increasing the hyperbolic deadband size H h further, because in contrast to results of ideal simulations, no significant additional concentration difference increase could be expected with larger hyperbolic deadbands when acknowledging the realistic sampling process. Also, the representativeness of updraft and downdraft samples for the JFD would be further decreased if larger deadbands would be applied. During the WALDATEM-2003 experiment, the overall proportions of evaluated samples in each sampling interval were 14.7(±3.0)% updrafts and 9.1(±2.6)% downdrafts. The difference in the number of updraft and downdraft samples results from skewness in the JFD and was discussed by Bowling et al. (1999b). The authors suggest an optimum deadband size at H h =1.1 and an asymmetric adjustment of the hyperbolas. We decided not to adjust the symmetric shape of the hyperbolic deadband, in order to prevent artifacts that could result from changing shapes of the JFD, which have to be considered above tall vegetation. CO 2 mixing ratio differences of whole-air HREA updraft and downdraft samples in the range of – 1.3 to –3.9 µmol mol −1 exceeded the tenfold measurement precision. Two samples marked with a ‘+’ in Figure 5a showed relatively small sample proportions. Their representativeness in respect to the JFD remains questionable. Furthermore, reduced precision of the CO 2 mixing ratio difference can
23 result from the transfer of relatively small amounts of sample air. Therefore, only simulated and corrected b-factors were used for the estimation of the isotope fluxes of these two samples in Figure 8b and 8c. The 13 C and 18 O isotopic differences, i.e. the difference of the isotope ratios of updraft and downdraft air samples, observed by the HREA measurements during WALDATEM-2003 were on average 0.11(±0.03)‰ for δ 13 C and 0.11(±0.02)‰ for δ 18 O during the time with sufficient sample drying (Table 2). Most values lie between the fivefold and tenfold standard deviations found in the whole-air REA system tests (dashed lines in Figure 8b and 8c, compare Figure 4). Similar δ 13 C differences were reported for many samples by Bowling et al. (1999a). Nevertheless, the small differences of the isotope ratios ask for high precision in the sample analysis. Based on the comparison of the isotopic differences and the precision determined in the whole-air REA system tests a measurement uncertainty due to the resolution of the isotopic differences of 10% to 20% can be estimated. The mixing ratio differences observed for CH 4 and N 2 O in daytime samples taken above the spruce forest at Waldstein/Weidenbrunnen during the WALDATEM-2003 experiment ranged from −2.9 to 1.6 nmol mol −1 for CH 4 and −0.37 to 0.49 nmol mol −1 for N 2 O. Most mixing ratio differences were in the order of measurement precision (1.3 nmol mol −1 for CH 4 and 0.13 nmol mol −1 for N 2 O) and consequently too small to be resolved by HREA sampling and whole-air analysis without pre-concentration on a trap. The indication of negative concentration differences and downward direction of CH 4 and N 2 O fluxes on average of the daytime samples was not significant (Table 2). Table 2. Concentration difference increase achieved by HREA sampling during the WALDATEM-2003 experiment and comparable data. Scenario Concentration difference increase HREA (H h =1.0) / REA (H w =0.6) Average scalar concentration differences HREA (H h =1.0) Simulation, ideal 1.78 this study, 1.84 (Bowling et al., 1999b) CO 2 : 4.9(±2.4) µmol mol −1 (Bowling et al., 1999b) based on data from Eastern USA deciduous forest Simulation, imperfect scalar similarity 1.73 this study, 1.65 (Ruppert et al., 2006b) Simulation, proxy scalar and σ w statistics defined from previous data and filter function 1.63 this study CO 2 : 2.4(±0.5) µmol mol −1 this study Measured, including physical sampling effects CO 2 : 2.3(±0.6) µmol mol −1 δ 13 C: 0.11(±0.03) ‰ VPDB δ 18 O: 0.11(±0.02) ‰ VPDB-CO 2 CH 4 : −0.4(±1.2) nmol mol −1 N 2 O: −0.02(±0.26) nmol mol −1
24 5. Conclusion Lab experiments with foil balloon bags and the complete whole-air REA system demonstrate their suitability for high precision isotope sampling for both 13 C and 18 O isotopes of CO 2 . This was indicated by a close match of isotope ratios found in air samples from two independent sampling systems. We therefore conclude that foil balloons are suitable flexible air collection containers for intermediate storage after cleaning as described in Section 4.1. Large whole-air sample volumes, precise flow and pressure control, careful material selection and treatment and effective sample drying helped to increase the sampling accuracy of the complete whole-air REA system especially for 18 O isotopes. δ 13 C/CO 2 and also δ 18 O/CO 2 correlations can therefore readily be investigated even at relatively small ranges of CO 2 mixing ratios. HREA measurements provide additional information on the scalar variation and on the most significant events in the turbulent isotopic exchange above the ecosystem for the determination of isofluxes. The comparison of measurement results and simulations of HREA sampling for bulk CO 2 confirmed good instrument performance and indicated 10 to 20% uncertainty for the quantification of fluxes due to the sampling method. The measured effective b-factors should be preferred for flux determination. Simulated b-factors require validation and potentially correction in order to prevent the risk of systematic underestimation of fluxes. Detailed axis rotation procedures for REA and HREA sampling without a time lag (Beverland et al., 1996b; McInnes et al., 1998; Moncrieff et al., 1998) can be implemented by evaluating the 3D wind vector and performing online planar-fit corrections (Wilczak et al., 2001). The precise synchronization of REA segregation valve switching can be achieved under defined sample flow conditions by differential cross-correlation measurements as outlined in Section 3.4. A concentration difference increase of 63% was achieved by applying the HREA sampling method instead of classical REA. Nevertheless, relatively small isotopic differences in updraft and downdraft samples collected during the WALDATEM-2003 and FORKAST-2010 experiments required high precision isotope analysis. The measurement uncertainty due to the chemical resolution of the isotope ratio differences was estimated at 10 to 20%. Whole-air HREA in combination with high precision isotope analysis can quantify isofluxes of 13 CO 2 and CO 18 O and collect additional information on the scalar correlation to bulk CO 2 , representing the relatively short timescale of upand downdrafts in the turbulent exchange above an ecosystem. 6. Acknowledgments The authors wish to thank Anthony C. Delany, Dave R. Bowling, and Nina Buchmann for helpful comments and discussions on the realization of the isotope REA technique by using whole-air balloon bag reservoirs. We acknowledge the support during the field experiments by Christoph Thomas, Matthias Mauder, Teresa Bertolini, Johannes Olesch, Johannes Lüers and the technical support performed by the staff of the Bayreuth Institute for Terrestrial Ecosystem Research (BITÖK) of the University of Bayreuth. The high precision laboratory analysis was performed by Michael Rothe and Armin Jordan in the Isotopeand Gas laboratory of the Max-Planck Institute in Jena. This study was supported by the German Federal Ministry of Education and Research (PT BEO51-0339476 D) and the Bavarian State Ministry of Sciences, Research and Arts with the joint research project “FORKAST” (“Investigation of carbon turnover of grasslands in a northern Bavarian low mountain range under extreme climate conditions”.
25 References Ammann, C. (1999), On the applicability of relaxed eddy accumulation and common methods for measuring trace gas fluxes, Geographisches Institut der ETH Zürich ed., ETH Zürich, Zürich, 230 pp. Ammann, C., and F. X. Meixner (2002), Stability dependence of the relaxed eddy accumulation coefficient for various scalar quantities, J. Geophys. Res., 107, (D8), 4071, doi:10.1029/2001JD000649. Baker, J. M., J. M. Norman, and W. L. Bland (1992), Field-scale application of flux measurement by conditional sampling, Agric. For. Meteorol., 62, 31-52. Beverland, I. J., J. B. Moncrieff, D. H. O'Neill, K. J. Hargreaves, and R. Milne (1996a), Measurements of methane and carbon dioxide fluxes from peatland ecosystems by the conditional-sampling technique, Quart. J. Roy. Meteor. Soc., 122, 819-838. Beverland, I. J., D. H. Oneill, S. L. Scott, and J. B. Moncrieff (1996b), Design, construction and operation of flux measurement systems using the conditional sampling technique, Atmos. Environ., 30, 3209-3220. Bowling, D. R., A. A. Turnipseed, A. C. Delany, D. D. Baldocchi, J. P. Greenberg, and R. K. Monson (1998), The use of relaxed eddy accumulation to measure biosphere-atmosphere exchange of isoprene and other biological trace gases, Oecologia, 116, 306-315. Bowling, D. R., D. D. Baldocchi, and R. K. Monson (1999a), Dynamics of isotopic exchange of carbon dioxide in a Tennessee deciduous forest, Glob. Biogeochem. Cycles, 13, 903-922. Bowling, D. R., A. C. Delany, A. A. Turnipseed, D. D. Baldocchi, and R. K. Monson (1999b), Modification of the relaxed eddy accumulation technique to maximize measured scalar mixing ratio differences in updrafts and downdrafts, J. Geophys. Res., 104, (D8), 9121-9133. Bowling, D. R., P. P. Tans, and R. K. Monson (2001), Partitioning net ecosystem carbon exchange with isotopic fluxes of CO 2 , Global Change Biol., 7, 127-145. Bowling, D. R., D. E. Pataki, and J. R. Ehleringer (2003a), Critical evaluation of micrometeorological methods for measuring ecosystem-atmosphere isotopic exchange of CO 2 , Agric. For. Meteorol., 116, 159-179. Bowling, D. R., S. D. Sargent, B. D. Tanner, and J. R. Ehleringer (2003b), Tunable diode laser absorption spectroscopy for stable isotope sudies of ecosystem-atmosphere CO 2 exchange, Agric. For. Meteorol., 118, 1-19. Brand, W. A. (2005), O 2 /N 2 Storage Aspects and Open Split Mass Spectrometric Determination, in Proceedings of the 12 th WMO/IAEA Meeting of Expert on Carbon Dioxide Concentration and Related Tracers Measurements Techniques, Toronto, Canada, Sept. 2003, WMO-GAW Report 161, edited by D. Worthy and L. Huang, pp. 146-151. Businger, J. A., and A. C. Delany (1990), Chemical sensor resolution required for measuring surface fluxes by three common micrometeorological techniques, J. Atmos. Chem., 10, 399-410. Businger, J. A., and S. P. Oncley (1990), Flux Measurement with conditional sampling, J. Atmos. Ocean. Tech., 7, 349-352. Canadell, J. G., H. A. Mooney, D. D. Baldocchi, J. A. Berry, J. R. Ehleringer, C. B. Field, S. T. Gower, D. Y. Hollinger, J. E. Hunt, R. B. Jackson, S. W. Running, G. R. Shaver, W. Steffen, S. E. Trumbore, R. Valentini, and B. Y. Bond (2000), Carbon metabolism of the terrestrial biosphere: A multitechnique approach for improved understanding, Ecosystems, 3, 115-130. Delany, A. C., S. P. Oncley, J. A. Businger, and E. Sievering (1991), Adapting the conditional sampling concept for a range of different chemical species, paper presented at Seventh symposium on meteorological observations and instruments, American Meteorological Society, Boston, New Orleans, La., 14-18 January 1991. Desjardins, R. L. (1977), Description and evaluation of a sensible heat flux detector, Boundary-Layer Meteorol., 11, 147-154. Ehleringer, J. R., D. R. Bowling, L. B. Flanagan, J. Fessenden, B. Helliker, L. A. Martinelli, and J. P. Ometto (2002), Stable isotopes and carbon cycle processes in forests and grasslands, Plant Biology, 4, 181-189. Foken, T., R. Dlugi, and G. Kramm (1995), On the determination of dry deposition and emission of gaseous compounds at the biosphere-atmosphere interface, Meteorol. Z., 4, 91-118. Foken, T., M. Göckede, M. Mauder, L. Mahrt, B. Amiro, and W. Munger (2004a), Post-field data qualtiy control, in Handbook of Micrometeorology, edited by X. Lee, et al., pp. 181-208, Kluwer, Dordrecht. Fotiadi, A. K., F. Lohou, A. Druilhet, D. Serca, Y. Brunet, and R. Delmas (2005), Methodological development of the conditional sampling method. Part I: Sensitivity to statistical and technical characteristics, Boundary-Layer Meteorol., 114, 615-640. Gao, W. (1995), The vertical change of coefficient b, used in the relaxed eddy accumulation method for flux measurement above and within a forest canopy, Atmos. Environ., 29, 2339-2347. Gerstberger, P., T. Foken, and K. Kalbitz (2004), The Lehstenbach and Steinkreuz Catchments in NE Bavaria, Germany, in Biogeochemistry of Forested Catchments in a Changing Environment: A German case study, edited by E. Matzner, pp. 15-41, Springer, Berlin. Guenther, A., W. Baugh, K. Davis, G. Hampton, P. Harley, L. Klinger, L. Vierling, P. Zimmerman, E. Allwine, S. Dilts, B. Lamb, H. Westberg, D. Baldocchi, G. Geron, and T. Pierce (1996), Isoprene fluxes measured by enclosure, relaxed eddy accumulation, surface layer gradient, mixed layer gradient, and mixed layer mass balance techniques, J. Geophys. Res., 101, (D13), 18555–18568. Hübner, J (2010), Einsatzvorbereitung einer REA-Anlage über Wiesenflächen, Diploma Thesis, University of Bayreuth, Germany, http://www.bayceer.uni-bayreuth.de/mm/de/top/diss/88759/DA_Joerg_Huebner.pdf Jordan, A., and W. A. Brand (2003), Technical Report: MPI-BGC, Germany, in Report of the Eleventh WMO/IAEA Meeting of Experts on Carbon Dioxide Concentration and Related Tracer Measurement Techniques, Tokyo, Japan, Sept. 2001, WMO-GAW Report 148, edited by S. Toru and S. Kazuto, pp. 149-153. Kaplan, J. O., I. C. Prentice, and N. Buchmann (2002), The stable carbon isotope composition of the terrestrial biosphere: Modeling at scales from the leaf to the globe, Glob. Biogeochem. Cycles, 16, 1060, doi:10.1029/2001GB001403.