scieee AI-readable full text Open interactive document viewer

Room Impulse Response Dataset: Niels Bohr Institute - Auditorium A

Figueroa-Duran, Antonio; Karakonstantis, Xenofon; Verburg, Samuel Arturo; Fernandez-Grande, Efren

Abstract

Dataset description This dataset is comprised of acoustic Room Impulse Response (RIR) measurements using different measurement equipment at the iconic Auditorium A, in the Niels Bohr Institute, Copenhagen. The measurements were carried out during the days July 22nd & 23rd, 2023. The dataset includes: rir_NBI_line.h5 – Sequential measurements over a line using a robotic arm (UR5, Universal Robots) for microphone positioning. rir_NBI_em32.h5 – Distributed RIRs measured with the 32-channel spherical microphone array Eigenmike (em32, mh Acoustics). rir_NBI_em32.sofa – SOFA format of the previous file. The room The Auditorium has a volume of approximately 126 m3 and is roughly rectangular with a tilted floor for the audience. The room was fully furnished with classroom equipment when measured. On one side wall, there are several interspaced windows. The reverberation time in octave bands is: F (Hz) 32 63 126 250 500 1k 2k 4k 8k 16k T30 (s) 0.75 0.74 0.61 0.72 0.80 0.88 1.03 1.05 0.85 0.58 The measurements All measurements were obtained using an exponential sweep covering the frequencies 20-20k Hz. The specific duration of the sweep varies with the measurement setup and can be found in the corresponding file. The sampling rate is 48 kHz. The source is a two-way loudspeaker (BM6, Dynaudio), and its position was kept constant throughout the entire measurement campaign. The remaining equipment utilised was an audio interface (Fireface UCX, RME), a loudspeaker amplifier, a microphone amplifier (Nexus, B&K). The atmospheric conditions for each set of measurements are included in the corresponding file. Related publications This dataset is linked to the publication: Figueroa-Duran A. & Fernandez-Grande E., Reconstruction of reverberant sound fields over large spatial domains. In J. Acoust. Soc. Am. (2025), https://doi.org/10.1121/10.0034833 Contact For any questions, please address them to [email protected].

Full text

NBI Dataset [email protected] DTU Electro Niels Bohr Institute – Auditorium A Dataset description This dataset is comprised of acoustic Room Impulse Response (RIR) measurements using different measurement equipment at the iconic Auditorium A, in the Niels Bohr Institute, Copenhagen. The measurements were carried out during the days July 22nd & 23rd, 2023. The dataset includes several files that contain the RIRs obtained by the different measurement devices. The files are as follows: • rir_NBI_line.h5 – Sequential measurements over a line using a robotic arm (UR5, Universal Robots) for microphone positioning. • rir_NBI_em32.h5 – Distributed RIRs measured with the 32-channel spherical microphone array Eigenmike (em32, mh Acoustics). • rir_NBI_em32.sofa – Previous file in SOFA format. The room The Auditorium has a volume of approximately 126 𝑚3 and is roughly rectangular with a tilted floor for the audience. The room was fully furnished with classroom equipment when measured. On one side wall, there are several interspaced windows. Fig. 1 Sketch of the room and the measurement setup The reverberation time in octave bands is: 𝐹0 (𝐻𝑧) 32 63 126 250 500 1k 2k 4k 8k 16k 𝑇30(𝑠) 0.75 0.74 0.61 0.72 0.80 0.88 1.03 1.05 0.85 0.58 NBI Dataset [email protected] DTU Electro The measurements All measurements were obtained using an exponential sweep covering the frequencies 20 − 20𝑘 𝐻𝑧. The specific duration of the sweep varies with the measurement setup and can be found in the corresponding file. The sampling rate is 48𝑘 𝐻𝑧. The source is a two-way loudspeaker (BM6, Dynaudio), and its position was kept constant throughout the entire measurement campaign. The remaining equipment utilised was an audio interface (Fireface UCX, RME), a loudspeaker amplifier, a microphone amplifier (Nexus, B&K). The atmospheric conditions for each set of measurements are included in the corresponding file. Fig. 2 Normalised Impulse Response measured along a line