scieee AI-readable full text Open interactive document viewer

Performance of scintillating tiles with direct silicon-photomultiplier (SiPM) readout for application to large area detectors

A. Balla; B. Buonomo; V. Cafaro; A. Calcaterra; F. Cardelli,; A. Ceccucci; P. Ciambrone; V. Cicero; D. Di Giovenale; C. Di Giulio; G. Felici; L.G. Foggetta; V. Giordano; G. Lanfranchi; I. Lax; A. Montanari; G. Papalino; A. Paoloni; T. Rovelli; A. Saputi;

Abstract

The light yield, the time resolution and the efficiency of different types of scintillatingtiles with direct Silicon Photomultiplier readout and instrumented with a customised front-endelectronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati andseveral test stands. The results obtained on minimum ionising particles with different detectorconfigurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230photo-electrons, and an efficiency better than 99.8% are obtained with ∼ 225 cm2large area tiles.This technology is suitable for a wide range of applications in high-energy physics, in particular forlarge area muon and timing detectors.

Full text

Journal of Instrumentation PAPER • OPEN ACCESS Performance of scintillating tiles with direct siliconphotomultiplier (SiPM) readout for application to large area detectors To cite this article: A. Balla et al 2022 JINST 17 P01038 View the article online for updates and enhancements. You may also like Use of active personal dosimeters in hospitals: EURADOS survey Olivera Ciraj-Bjelac, Eleftheria Carinou and Filip Vanhavere - Recent progress of SiC UV single photon counting avalanche photodiodes Linlin Su, Dong Zhou, Hai Lu et al. - A review on III–V compound semiconductor short wave infrared avalanche photodiodes Yan Liang, Chandrasekar Perumal Veeramalai, Guochen Lin et al. - This content was downloaded from IP address 194.12.139.93 on 24/11/2025 at 13:28 2022 JINST 17 P01038 Published by IOP Publishing for Sissa Medialab Received:October 8, 2021 Accepted:January 17, 2022 Published:January 27, 2022 Performance of scintillating tiles with direct silicon-photomultiplier (SiPM) readout for application to large area detectors A. Balla,𝑎B. Buonomo,𝑎V. Cafaro,𝑏A. Calcaterra,𝑎F. Cardelli,𝑎A. Ceccucci,𝑐 P. Ciambrone,𝑎V. Cicero,𝑏,𝑑 D. Di Giovenale,𝑎C. Di Giulio,𝑎G. Felici,𝑎L.G. Foggetta,𝑎 V. Giordano,𝑏G. Lanfranchi,𝑎I. Lax,𝑏A. Montanari,𝑏G. Papalino,𝑎A. Paoloni,𝑎,∗ T. Rovelli,𝑏,𝑑 A. Saputi,𝑎G. Torromeo𝑏and N. Tosi𝑏 𝑎INFN — Laboratori Nazionali di Frascati, via E. Fermi 40, 00044 Frascati (Rome), Italy 𝑏INFN — Sezione di Bologna, Viale Berti Pichat, 6/2, 40127 Bologna, Italy 𝑐CERN, 1211 Geneva 23, Switzerland 𝑑Dipartimento di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat, 6/2, 40127 Bologna, Italy E-mail: [email protected] Abstract: The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained on minimum ionising particles with different detector configurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230 photo-electrons, and an efficiency better than 99.8% are obtained with ∼ 225 cm 2 large area tiles. This technology is suitable for a wide range of applications in high-energy physics, in particular for large area muon and timing detectors. Keywords: Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators) ArXiv ePrint:2109.08454 ∗Corresponding author. c 2022 CERN. Published by IOP Publishing Ltd on behalf of Sissa Medialab. Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. https://doi.org/10.1088/1748-0221/17/01/P01038 2022 JINST 17 P01038 Contents 1 Introduction 1 2 The prototypes 2 3 Front-End Electronics 2 4 Determination of the intrinsic time jitter of SiPMs and electronics 5 5 Calibration of the light yield 6 6 Test beam measurements 7 6.1 Test beam setup 7 6.2 Test beam results 8 7 Cosmic rays measurements 12 8 Simulation 19 9 Conclusions 20 1 Introduction Organic scintillators offer a fast response and high light yield for moderate cost, making them a good choice for the application in large area detectors for particle physics. Silicon Photo-Multipliers (SiPMs) 1 ) [ 1 ] provide advantageous properties such as good timing, compactness, and high Photon Detection Efficiency (PDE). Scintillating tiles with direct SiPM readout, pioneered for application in hadron calorimeters for electron-positron colliders [ 2 , 3 ], allow compact detectors with high granularity and good time resolution to be built. In addition to a very good timing performance, the choice of tiles guarantees the determination of the 𝑥, 𝑦 coordinates with a single active layer and a good tolerance against hit rate variations. Studies performed on similar scintillator-based detectors [ 4 ] show that this technology is suitable for detectors exposed to an integrated dose of about 100 kRad/year. Moreover the construction and assembly procedure is modular and therefore can be easily shared among different production sites, which is paramount for the construction of large area detectors. This article describes the performance obtained on 225 cm 2 area scintillating tiles with direct SiPM readout developed for possible use in large area muon systems, as for example, the muon system of the proposed SHADOWS experiment [ 5 ]. However, the modular structure and the very competitive cost render this system suitable to multiple applications in high energy physics and beyond, in particular for large area detectors. 1Also known as Multi-Pixel Photon Counters (MPPCs). –1– 2022 JINST 17 P01038 2 The prototypes Four tile prototypes have been built and characterised at several test stands in Frascati and Bologna INFN laboratories and their performance assessed during a test beam at the Beam Test Facility (BTF) of Laboratori Nazionali di Frascati in January 2021. Two (out of four) tiles are made of EJ200 cast organic scintillator from Eljen company 2 and the other two by organic scintillator from UNIPLAST (Vladimir, Russia). The tiles dimensions are of ( 150 × 150 × 10 ) mm 3 for both UNIPLAST and for Eljen company. Each tile is read out by four SiPMs placed at the tile corners, either engraved into slots dug in the scintillator or glued at the cut corners. An example of prototype with the four SiPMs connected to flex cables and glued in slots engraved at the tile corners is shown in figure 1. Three out of four tiles are painted with three layers of reflective painting Eljen EJ-510, 3 while the fourth one is covered by a chemical reflector obtained by etching the scintillator surface in a chemical agent, that results in the formation of a white micropore deposit over polystyrene [ 6 ]. All tiles are wrapped with Teflon tape to ensure light tightness. The main characteristics of the four tiles under test are summarised in table 1. Table 1 . Main characteristics of the four tiles under test and average breakdown voltage of the four SiPMs in each tile. Scintillator Dimensions SiPM placement coating 𝑉break (V) Tile 1 EJ200 (150 ×150 ×10)mm3slots painting + Teflon 38.34 ±0.06 Tile 2 EJ200 (150 ×150 ×10)mm3corners painting + Teflon 38.43 ±0.09 Tile 3 UNIPLAST (150 ×150 ×10)mm3slots etching + Teflon 38.55 ±0.05 Tile 4 UNIPLAST (150 ×150 ×10)mm3slots painting + Teflon 38.31 ±0.08 The tiles are read out by four SiPMs, Hamamatsu S14160-6050HS, with 6 × 6mm 2 active area. The other characteristics of the SiPMs, as deduced from the datasheet, 4 are reported on table 2. The V-I curve of every SiPM has been measured and the breakdown voltage ( 𝑉break ) determined. SiPMs with similar 𝑉break have been grouped on each tile, for which the average 𝑉break is also provided on table 1, together with the rms of the four values. The SiPMs are mounted on short Kapton flex cables that ensure the connection with the motherboard (see section 3). The flex cable end hosting the SiPM is glued to the tile via optical glue Eljen EJ-500.5The other end is connected to mezzanines placed on the motherboard attached to the tile surface, where the Front-End Electronics (FEE) is located. All the details of the FEE are given in section 3. 3 Front-End Electronics The FEE for the tile prototypes has been designed following a mother-board/daughter-boards approach with off-the-shelf components. In this way different amplifier topologies can be tested without affecting the SiPM-board connections. The picture of a fully instrumented scintillator tile is shown in figure 2. 2https://eljentechnology.com. 3https://eljentechnology.com/products/accessories/ej-510-ej-520. 4https://www.hamamatsu.com/eu/en/product/type/S14160-6050HS/index.html. 5https://eljentechnology.com/products/accessories/ej-500. –2– 2022 JINST 17 P01038 Figure 1 . Tile prototype with white reflecting painting. The four SiPMs are attached to flex cables glued in grooves inside the scintillator at the tile corners. Table 2 . Main characteristics of Hamamatsu S14160-6050HS SiPMs. The PDE, gain, dark current and crosstalk values are given for the suggested operation voltage of 𝑉break +2.7V. Number of channels 1 Pixel pitch 50 μm Number of pixels 14331 𝑉break ∼38 V PDE 50% Gain o(106) Typical dark current value 2.5 μA Crosstalk probability 7% As well known the time resolution depends on both signal slew rate and noise, therefore photon collection must be maximised by means of large area SiPMs and high bandwidth readout electronics. Unfortunately large area SiPMs have a large parasitic capacitance that increases the amplifier input noise, reducing the overall signal-to-noise S/N ratio. A reduction of the parasitic capacitance could be achieved by connecting SiPMs in series, but this configuration requires higher supply voltages and reduces the signal amplitude and therefore it is not the best choice for a topology where SiPMs are spread over a large area. For our readout topology, SiPMs instrumented with individual preamplifiers followed by a common summing point is a preferable solution as it allows local signal amplification and the possibility of adjusting the shaping time both at the preamplifier input and at the common summing point. The readout circuit block diagram is shown in figure 2: each SiPM output is amplified and combined with signals from the other amplifiers by means of a summing amplifier. The summing amplifier output is, finally, routed to a digitizer. The mother board connections have been designed to equalise the propagation delay of the signals from the four (local) SiPM amplifiers. –3– 2022 JINST 17 P01038 AMPLIFIER1 SiPM1 AMPLIFIER2 SiPM2 AMPLIFIER3 SiPM3 AMPLIFIER4 SiPM4 SUMMING AMPLIFIER Figure 2. Picture of a fully instrumented tile (left) and its readout circuit block diagram (right). The mother-board PCB includes connectors for both preamplifiers and summing amplifier, SiPM bias circuits and low-voltage regulators. Four layers PCBs have been used for proper impedance signal routing traces and low-impedance supply voltage distribution. MCX connectors have been chosen for analog signal transmission while MOLEX nano-fit connectors have been used for low-voltage and SiPM bias distribution. The SiPMs are connected to the preamplifier via low impedance short kapton flex cables allowing easy replacement of the full readout circuit in case of failures. Because of the SiPMs large parasitic capacitance (of the order of 2 nF), front-end preamplifiers with low input impedance must be used. Two basic configurations have been selected for the front-end design: the current feedback and the current conveyor. For each configuration two different readout circuits have been investigated; the basic schematics are shown in figure 3. The first two circuits (Type 1 and Type 2) are based on the current conveyor configuration 6 and implemented by means of a NPN BFR92A RF transistor while Type 3 and Type 4 are based on the transimpedance configuration. 7 Table 3shows the main features of the two configurations. All circuits are AC coupled then allowing baseline fluctuation suppression using low capacitors values; Type 1 circuit includes a local buffer for pole-zero compensation at the summing point while Type 4 configuration helps in suppressing pickup noise (within the amplifier bandwidth). All configurations have been tested in a cosmic ray stand; a detailed description of the test outcome can be found in section 7, while examples of the waveforms collected on the same tile with the four different electronics is shown in figure 4. As the four configurations do not show significant differences in the time resolution measurement, the current conveyor one has been selected to carry out the Test Beam, because its resistive input impedance is stable over all the input transistor bandwidth. Finally, to avoid spoiling the signal time information, low impedance connections to the summing point together with a high speed amplifier must be used; in our design signals have been 6Current Conveyor: 𝑅𝑐=collector resistor, 𝐶par =collector parasitic capacitance 7Transimpedance: 𝑅𝑓=feedback resistor, 𝐶par =input parasitic capacitance –4– 2022 JINST 17 P01038 SiPM SiPM SiPM SiPM SUM SUM SUM SUM Vbias VDD VEE VBIAS TYPE 1 Vbias VDD VEE VBIAS TYPE 2 VBIAS TYPE 3 VBIAS TYPE 4 --- C:\Users\felici\Dropbox\NOTE\SHADOW\Articolo\LT_SCHEMATICS\pre_type1.asc --- Figure 3 . Different tested FEE types. Type 1: buffered common base, Type 2: common base, Type 3: transimpedence, Type 4: differential readout based on transimpedence configuration. Table 3. Preamplifier configurations characteristics (a fixed gain has been assumed). Current Conveyors Transimpedance 𝑍in small (current sensitive) 𝑍in ≃0(virtual ground) 𝑍out large (current output) 𝑍out low (voltage output) Transfer function ≃𝑅𝑐Transfer function ≃𝑅𝑓 𝑍in =1/𝑔𝑚𝑍in =𝑍𝑓/(𝐺+1) Bandwidth=1/2𝜋𝑅𝑐𝐶par Bandwidth=1/2𝜋𝑅 𝑓𝐶par routed by means of 50 ohm microstrips while the summing point has been implemented using the AD8009, a very fast operational amplifier from Analog Devices.8 4 Determination of the intrinsic time jitter of SiPMs and electronics In order to optimise the overall design of the tiles and corresponding front-end electronics, it is important to disentangle the individual contributions to the combined time resolution. The contribution of the SiPM itself combined with the readout electronics has been measured without the 8 the AD8009 is a high-speed current-feedback amplifier (1 GHz bandwidth) from Analog Devices capable to exploit a 5500 V/μs slew rate resulting in a sub-ns rise-time if used in low-gain configurations. –5– 2022 JINST 17 P01038 Time (ns) 0 20 40 60 80 100 120 140 160 180 200 Amplitude (mV) 100 200 300 400 500 Type 1 FEE Time (ns) 0 20 40 60 80 100 120 140 160 180 200 Amplitude (mV) 50 100 150 200 250 300 350 Type 2 FEE Time (ns) 0 20 40 60 80 100 120 140 160 180 200 Amplitude (mV) 0 50 100 150 200 250 300 350 Type 3 FEE Time (ns) 0 20 40 60 80 100 120 140 160 180 200 Amplitude (mV) 50 100 150 200 250 300 350 400 Type 4 FEE Figure 4. Examples of waveform acquired on tile 4 at 41.5 V bias voltage with the four different FEE. scintillator. A pulse of light, provided by a PiL040x 405 nm laser, was guided onto a single SiPM connected to Type 2 FEE, as in the test beam. The pulse amplitude was tuned to obtain signals of amplitude comparable to that observed with MIPs. The analog output of the amplifier was acquired together with the sync signal from the laser on a LeCroy WR8000 oscilloscope, operated at 20 GSamples/s. The oscilloscope was configured to measure the time difference between the two signals, defined as a constant fraction of the SiPM output. Two fractions of the maximum amplitude have been considered, 20% and 30%. The standard deviations of the difference, over 1000 laser pulses, are shown in figure 5as a function of SiPM bias voltage. Since no obvious dependency was observed, a simple average over all the bias values was taken, yielding a jitter of 74(80) ps at 30(20)% constant fraction threshold. Subtracting the full contribution of the laser system (nominally 45 ps), a lower limit for jitter of 66 ps at 20% threshold was found. 5 Calibration of the light yield In order to express the tiles light yield in number of photo-electrons, the gain of the SiPM and readout electronics has been calibrated by acquiring its signal charge spectrum produced with a low-intensity pulsed led light. The hardware setup used for this measurement consists of a light-tight climate chamber containing a single SiPM connected to the readout electronics. The light of an LED connected to a pulse generator is directed onto the active surface of the SiPM by an optical fiber, and the amplifier output signal waveforms are acquired by a digital oscilloscope, operated at 10 GS/s. The output charge was measured by integrating the signal waveform within a 200 ns window, similarly to the analysis of test beam data. To obtain a good separation in the charge spectrum between peaks corresponding to different number of photoelectrons, the climate chamber temperature was set to 0 ◦ C to reduce the SiPM –6– 2022 JINST 17 P01038 Figure 5 . Standard deviation of the difference between laser pulse and SiPM signal, at a given threshold fraction, as function of applied bias voltage. thermal noise. In order to operate the SiPM at the same gain as at room temperature during the test beam, the bias voltage had to be adjusted to account for the breakdown voltage ( 𝑉break ) dependence on temperature, keeping fixed the over-voltage. The 𝑉break was determined at 0 ◦ C temperature by acquiring the V-I curve with a Keysight B2901A source meter. In a V-log(I) plot, the intersection of the linear fits for the dark current region and the breakdown region provides the sought voltage, yielding a 𝑉break of 37.35 V. A charge spectrum, shown in figure 6, was acquired and the peaks fitted with a sum of multiple Gaussian functions. The average distance between two adjacent peaks corresponds to the signal generated by 1 p.e. The resulting charge produced by a single photoelectron is 3.2±0.2pC. 6 Test beam measurements 6.1 Test beam setup Tests with an electron beam have been conducted at the Beam Test Facility (BTF) of Laboratori Nazionali di Frascati. The BTF is a beam transfer line designed for the optimised, stochastic production of single electrons/positrons for detector calibration purposes. Electron and positron beams are created in the energy range of 25–500 MeV with an energy spread of 1% and a repetition rate varying between 10 and 40 Hz. The typical spot size can vary within (1–25) mm in 𝑦 and (1–55) mm in 𝑥 and the divergence within 1–2 mrad. Beam characteristics (spot size, divergence, momentum resolution) are dependent strongly on the multiplicity (number of particles/bunch) and energy requested. For the test beam the chosen configuration was an electron beam of 450 MeV energy with an average particle multiplicity per bunch of 1.8 and a spot size of 𝜎𝑥= 1 . 4mm and 𝜎𝑦= 0 . 8mm, as evaluated at the beam pipe exit [ 7 ]. The beam spot size on the tiles under test, due to the distance from the beam pipe exit, was of few mm2. During the test beam campaign the four tiles equipped with Type 2 FEE were hosted into a light-tight box that acted also as a Faraday cage. The system, composed by the four tiles and the box, –7– 2022 JINST 17 P01038 Figure 15. Positions of the beam on the mini-module during the scan performed at the BTF test beam. Figure 16. Cosmic ray set-up with the four tiles piled up. The tiles are labelled as in table 1. – 14 – 2022 JINST 17 P01038 Table 4 . Results of the scan over the mini-module. The points used during the scan are shown in figure 15. For each of them the positions with respect to the (0,0) coordinate at the mini-module centre, the average time arrival, the resolution of the time arrival, and the light yield are shown. The time resolution is already corrected for the 𝑇0 time jitter, while the conversion of the light yield in photo-electrons is performed exploiting the calibration described in section 5. Tile Label Position Average arrival time arrival time resolution light yield n. [cm,cm] [ns] [ps] [N p.e.] 1 A [−7.5,7.5]8.93 ±0.003 226 ±2 230 ±20 1 B [−3.5,7.5]8.87 ±0.003 219 ±3 250 ±21 1 C [−0.5,7.5]8.82 ±0.003 210 ±1 260 ±20 1 D [−3.5,3.5]8.572 ±0.003 243 ±3 300 ±30 1 E [−1.5,1.5]7.992 ±0.003 228 ±3 520 ±80 2 A [7.5,7.5]8.696 ±0.003 237 ±3 186 ±16 2 B [3.5,7.5]8.615 ±0.003 226 ±3 205 ±20 2 C [0.5,7.5]8.541 ±0.003 222 ±3 217 ±20 2 D [3.5,3.5]8.468 ±0.003 227 ±3 263 ±30 2 E [1.5,1.5]8.542 ±0.003 223 ±3 640 ±110 3 A [7.5,−7.5]9.188 ±0.003 229 ±2 207 ±18 3 B [3.5,−7.5]8.991 ±0.007 234 ±7 230 ±22 3 C [0.5,−7.5]8.943 ±0.007 239 ±6 231 ±18 3 D [3.5,−3.5]8.797 ±0.003 237 ±3 358 ±44 3 E [1.5,−1.5]7.87 ±0.003 227 ±3 680 ±200 4 A [−7.5,−7.5]10.231 ±0.003 248 ±2 138 ±13 4 B [−3.5,−7.5]10.154 ±0.003 247 ±2 143 ±14 4 C [−0.5,−7.5]10.172 ±0.003 245 ±3 141 ±13 4 D [−3.5,−3.5]9.927 ±0.003 230 ±3 183 ±20 4 E [−1.5,−1.5]9.898 ±0.003 207 ±3 397 ±78 A toy MonteCarlo simulation has been developed to estimate systematic effects due to the cosmics angular distribution, assuming the widely used cos2𝜃𝑑Ω angular distribution [ 8 ]. The angular distribution for cosmic rays triggered by the external tiles is shown in figure 17 together with the distributions of the estimated time-of-flight between the central ones. The spatial distribution of the impact point in one of the trigger and in one of the central tiles is also shown. As a consequence of the cosmic rays angular distribution, the time-of-flight between the central tiles has an rms of 11 ps, that will be neglected in the following analysis. Triggered cosmic rays are focused in the centre of the inner tiles, and even though impinging on the entire surface, ten times more events crossing the central area are detected with respect to peripheral zones. For the external tiles, used as trigger, the flux is more uniform, at the level of ±20%. For the analysis of the digitized signals, baseline values have been estimated for each tile, averaging the first 150 samples (corresponding to 30 ns), and then subtracted. From the study of baseline distributions, similar electronics noise values as those observed at the test beam, shown in figure 11, have been inferred. The signals of the four tiles have been discriminated at 20% of their – 15 – 2022 JINST 17 P01038 HTheta Entries 9930623 Mean 0.2351 RMS 0.1113 (rad)θ 0 0.2 0.4 0.6 0.8 0 50 100 150 200 250 300 3 10×HTheta Entries 9930623 Mean 0.2351 RMS 0.1113 Htof Entries 9930623 Mean 0.3571 RMS 0.01052 Time-of-flight (ns) 0.32 0.34 0.36 0.38 0.4 0.42 0.44 0 100 200 300 400 500 600 700 3 10×Htof Entries 9930623 Mean 0.3571 RMS 0.01052 X (cm) 0 2 4 6 8 10 12 14 Y (cm) 0 2 4 6 8 10 12 14 9500 10000 10500 11000 11500 12000 Impact point on trigger tile 1 X (cm) 0 2 4 6 8 10 12 14 Y (cm) 0 2 4 6 8 10 12 14 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 Impact point on test tile 1 Figure 17 . Cosmic rays simulation: distribution of the zenith angle, 𝜃 (top left), estimated time-of-flight between the central tiles (top right), impact point spatial distribution for one of the external (bottom left) and one of the internal (bottom right) tiles. amplitudes and the time resolution has been estimated using the time-of-flight between the central tiles, by fitting the distribution with a Gaussian function and dividing its sigma by √2 . Events with signal amplitudes lower than 50 mV or higher than 950 mV (the digitizer has 1 V range) in either of the central tiles have been discarded. The measured time resolutions with the four different FEE types are reported in figure 18 for a bias voltage ranging from 39 V to 42.5 V at a temperature between 22 and 26 ◦ C. The best performance is obtained with Type 1 FEE ( 𝜎∼ 230 ps for 1 V over-voltage), while the worst with Type 4; the other two types have resolutions around 260 ps. For a better understanding, in table 5the amplitude Most Probable Value (MPV, obtained by means of a Landau fit) and the rise time (from 10% to 90% of the amplitude) are reported for the signals acquired at 41.5 V with the different electronics on tile 4: Type 1 electronics is the fastest one, but not the one with the greatest amplification. Waveform examples acquired on tile 4 with the four different FEEs at a bias voltage of 41.5 V are shown in figure 4. For sake of comparison, the arrival times in the tiles have been estimated also with the same algorithm used for the test beam data analysis. The difference in time resolutions for most of the measurements is lower than 5%, which is taken as a systematic error. Table 5. Tile 4 signal characteristics at 41.5 V bias voltage using the four different electronics types. Electronics type Amplitude MPV (mV) Risetime (ns) Type 1 281.6±0.8 5.4±0.1 Type 2 259.8±0.7 10.6±0.1 Type 3 170.5±0.8 6.5±0.1 Type 4 507.7±1.5 5.7±0.1 It is worth mentioning here that the time resolutions reported in this section are expected to be worse than those measured at the test beam, as a consequence of the fact that cosmic rays are – 16 – 2022 JINST 17 P01038 Vbias (V) 38.5 39 39.5 40 40.5 41 41.5 42 42.5 43 Time resolution (ps) 150 200 250 300 350 400 450 500 TYPE 1 TYPE 2 TYPE 3 TYPE 4 Figure 18 . Time resolution measured using cosmic rays with the four different electronics as a function of the SiPM bias voltage. triggered on a larger area and fluctuations on the light collection time play a more important role. To estimate the overall time resolution for an uniform illumination of the tiles under test, data have been acquired also triggering on the central tiles, put at a mutual distance of 30 cm, in order to reproduce the distribution shown at bottom left of figure 17. The measured time resolution with Type 2 FEE is 306 ps, with a 10% systematic error from the comparison between the two employed analysis methods. This value has to be compared with ∼ 220 ps measured with the focused beam at BTF facility and ∼260 ps measured with focused cosmic rays as bottom right of figure 17. Profiting of data acquired by triggering on the coincidence of the central tiles at 30 cm distance, together with those acquired for the time resolution measurements, we have compared the MPV of the signal amplitude distribution for the four different tiles at the same conditions: Type 2 FEE, 𝑉bias = 41 . 5V and (almost) uniform cosmic rays impact point distribution (bottom left of figure 17). The measured values are reported in table 6, where the same notation of the test beam for the tile identification has been used, for light yield comparison. The best light yield is obtained for tiles 1 and 3, while worse results are obtained for tile 2 (without slots for the SiPMs) and for tile 4 (reflecting coating obtained by painting rather than etching). Similar conclusions can be drawn from test beam data, as reported on table 4, where light yields can, for instance, be compared for electrons crossing the centre of the tiles (point A). For measuring the efficiency, two additional tiles, ( 9 × 9 )cm2 wide, have been added at the two extremities of the set-up, well inside the area of the tiles under test. Their discriminated signals have been added to the trigger in coincidence with the two external tiles. In addition, tiles 2 and 4, as well as tiles 3 and 1, have been put in close contact each other, to have all the four tiles under test within a distance of about 10 cm. For the efficiency estimation of tiles 3 and 4, a signal above 30 mV in a 30 ns time window with respect to the trigger is required in the other three tiles; the – 17 – 2022 JINST 17 P01038 Table 6 . MPV of the signal amplitude distribution for the four tiles equipped with Type 2 FEE at 𝑉bias = 41 . 5V. MPV (mV) Tile 1 461.7±2.0 Tile 2 356.4±1.2 Tile 3 468.3±1.6 Tile 4 261.7±1.1 tile is considered efficient if a signal above 30 mV has been recorded. In figure 19 the measured efficiencies as a function of 𝑉bias are shown for Tiles 3 and 4. For 𝑉bias > 39 . 5V (more than 1 V over-voltage) efficiency values greater that 99.8 % have been measured for both tiles. Given the use of the cosmic rays without tracking devices for event reconstruction, we assume this value as a lower limit. Similar values have been obtained for Tiles 1 and 2, exploiting the same set-up with Tiles 3 and 4 in the trigger. Vbias (V) 38 38.5 39 39.5 40 40.5 41 41.5 42 42.5 43 Efficiency (%) 98 98.2 98.4 98.6 98.8 99 99.2 99.4 99.6 99.8 100 Tile 4 Tile 3 Tile 2 Tile 1 Figure 19 . Efficiency values measured for Tiles 3 and 4 on cosmic rays as a function of 𝑉bias . A threshold of 30 mV on Type 2 FEE output has been applied. The efficiency values reported above have been measured without time cuts on the signals of the tested tiles; plastic scintillators however are often considered for use as veto detectors with very tight cuts on their signal arrival times. We also performed therefore a dedicated study on the efficiency loss as a function of a cut on the arrival time using the time-of-flight between the central tiles in the cosmic ray set-up shown in figure 16. The percentage of events for which the time-of-flight (TOF) is outside of a given cut is shown in figure 20 in terms of 𝜎TOF . Less than 5% of the events are cut outside of 2𝜎(0.5% outside of 3𝜎). – 18 – 2022 JINST 17 P01038 )σN ( 1 1.5 2 2.5 3 3.5 4 (%)∈ ∆ -1 10 1 10 Figure 20 . Percentage of events ( Δ𝜖 ) cut symmetrically at 𝑁×𝜎 on the distribution of the time-of-flight between the central tiles in the cosmic ray set-up. 8 Simulation The hardware R&D activity has been complemented by a detailed FLUKA [ 9 ] simulation of the combined response of the tile and of the photo-sensors to a minimum ionizing particle. The FLUKA package (version 2020.0.6) has been used with Flair [ 10 ] (version 2.3.0) as graphical user interface. A squared ( 15 × 15 ) cm 2 tile, made of EJ200 scintillator and read by four ( 6 × 6 ) mm 2 Hamamatsu SiPMs at the corners has been simulated. Figure 21 shows a rendering of the tile geometry and a detailed view of the SiPM placed in its slot. Figure 21 . Rendering of the tile geometry (left) used in FLUKA simulations and close-up of SiPM slot (right). The EJ200 scintillator properties (attenuation length, scintillation efficiency, emission spectrum, raise/decay times) and the photo-detection efficiency versus wavelength of the SiPMs used during tests have been implemented. Also the glue around the SiPMs with its optical properties has been – 19 – 2022 JINST 17 P01038 taken into account. The efficiency of the optical coupling was fixed to 95%. Photons hitting the 𝑇𝑖𝑂2 coating undergo to diffuse reflection with 90% reflectivity. The SiPM output is calculated based on the photons reaching the SiPM window with an empirical response function: for each photoelectron an output signal is computed and the output signal waveform is produced summing over all photoelectrons. The tile output signal is then obtained by adding all four SiPMs waveforms. We simulated the tile response to an electron beam with energy and focusing dimensions equivalent to the one used during the test beam measurement campaign, in order to perform a direct comparison. Simulated signals from the tiles have been discriminated at 20% of their amplitudes and the corresponding times recorded. The contribution of the time jitter due the SiPM and Type 2 FEE response has been taken into account by smearing the arrival times by a gaussian function according to the measurements reported in section 4. The time resolution has been determined by fitting the resulting distribution with a Gaussian function. Figure 22 shows the distribution of detected photons of a sample of 20k events, with the beam passing through the tile center: a MPV of 222 ± 12 p.e is measured, which is in good agreement with the test beam measured value of 230 ± 20 p.e ( see table 4). The simulated time resolution with a 20% threshold is 215 ± 1ps, in reasonable agreement with the measured value (table 4). 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 ns 0 20 40 60 80 100 120 N Entries 19945 Mean 0.001524± 1.134 Std Dev 0.001078± 0.2153 Underflow 0 Overflow 0 / ndf 2 χ 1134 / 24 Constant 0.9± 110.4 Mean 0.001± 1.132 Sigma 0.0008± 0.2042 Time distribution Figure 22 . Distribution of the number of detected photo-electrons (left) and of the tile response time (right) with simulated electron beam events. Similarly we simulated the tile response to cosmic muons with a 𝑐𝑜𝑠2𝜃𝑑Ω angular distribution as described in section 7. Figure 23 shows the distribution of detected photons (left) and the time distribution (right) for a sample of 20k events generated according to the spatial distribution shown in figure 17 (bottom right). The tile time resolution worsen with respect to the simulated electron beam data, resulting in 258 ± 1ps, which is in agreement with the results observed in laboratory measurements with Type 2 FEE, shown in figure 18. Finally, a uniform cosmic muon distribution was simulated, shown in figure 24. In this case the time resolution is 282 ±1ps, in good agreement with the measured value. Table 7shows the comparison between data and simulation for the time resolution measured with the Tile 1 illuminated with: i) an electron beam in positions A,B,D as in figure 15; ii) cosmic rays. 9 Conclusions In this paper the performances of four ( 150 × 150 × 10 ) mm 3 scintillating tiles, each read out by four SiPMs Hamamatsu S14160-6050HS with ( 6 × 6 ) mm 2 active area, have been investigated in terms of light yield, time resolution and efficiency. Different construction techniques have also been compared. – 20 – 2022 JINST 17 P01038 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 ns 0 200 400 600 800 1000 1200 1400 1600 N Entries 19968 Mean 0.001826± 1.007 Std Dev 0.001291± 0.258 Underflow 2 Overflow 0 / ndf 2 χ 149.3 / 36 Constant 13.2± 1557 Mean 0.002± 1.005 Sigma 0.001± 0.254 Time distribution Figure 23 . Distribution of the number of detected photo-electrons (left) and of the tile response time (right) with simulated cosmic muons events. Entries 19999 Mean 284.7 Std Dev 79.25 Underflow 173 Overflow 18 / ndf 2 χ 1479 / 94 Constant 104.1± 9296 MPV 0.3± 243.3 Sigma 0.14± 16.23 100 200 300 400 500 600 700 800 900 n. of phel. 0 200 400 600 800 1000 1200 1400 1600 n. of eEntries 19999 Mean 284.7 Std Dev 79.25 Underflow 173 Overflow 18 / ndf 2 χ 1479 / 94 Constant 104.1± 9296 MPV 0.3± 243.3 Sigma 0.14± 16.23 n. of photoel. (cosm.mu) 6−4−2−0 2 4 6x (cm) 6− 4− 2− 0 2 4 6 y (cm) 10 15 20 25 30 35 40 45 n entries Cosmic position 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 ns 0 200 400 600 800 1000 N Entries 19909 Mean 0.001999± 0.9424 Std Dev 0.001413± 0.282 / ndf 2 χ 201.2 / 36 Constant 9.6± 1127 Mean 0.0020± 0.9407 Sigma 0.0013± 0.2792 Time distribution Figure 24 . Tile simulation with an uniform muon flux: distribution of the number of detected photo-electrons (top), impact point spatial distribution (bottom left) and tile response time (bottom right). Tiles 1 (EJ200 scintillator painted with reflecting painting) and 3 (UNIPLAST scintillator with reflective layer obtained by chemical etching) have the best light yield, more than 200 photo-electrons for minimum ionizing particles impinging on the center of the tile. A worse performance is obtained with Tile 2 (EJ200 scintillator with SiPMs glued on cut corners rather than engraved inside the tile) and Tile 4 (UNIPLAST scintillator painted with reflective painting). – 21 – 2022 JINST 17 P01038 Table 7 . Comparison between data and simulation for the time resolution measured with the Tile 1 illuminated with: i) an electron beam in positions A,B,D as in figure 15; ii) cosmic rays uniformly distributed. position A position B position D cosmic rays 𝜎𝑡(data, ps) (226 ±2) (219 ±3) (243 ±3) (306 ±30) 𝜎𝑡(simulation, ps) (204 ±1) (203 ±1) (225 ±1) (282 ±1) Despite the quite different light yield values, the four tiles show a similar performance in terms of time resolution, as measured in the BTF test beam. A possible explanation is that the dependence of the time resolution on the light yield is relaxed for a sufficiently high number ( > 100) of photo-electrons. By means of cosmic muons, we have measured the overall time resolution for an uniform illumination of the tile, which is 306 ps with a systematic error of the order of 10% from the comparison of the results with the two different considered analyses. In case of a uniform illumination of the tile, a worse time resolution is expected because of the contribution due to the light propagation from the particle impact point to the nearest SiPM. With the cosmic ray set-up, efficiency values greater than 99.8 % have been observed for all the tiles. The measured light yield and time resolution values have been cross-checked by means of a FLUKA based MonteCarlo simulation, which can be further used to estimate the performances of tiles with different geometries. The agreement within data and Montecarlo is good, at a level better than 10% for all the data samples considered: test beam electrons as well cosmic rays, both with a focused and an uniform illuminations. Different Front-End electronics have been also tested; the best timing performances are obtained with the current conveyor configuration. This technology is therefore proven to be suitable for large area scintillating detectors when time resolution of 200–300 ps and very high efficiency are required. Acknowledgments We are indebted to B. Ponzio (INFN-LNF) for his support for the installation of the remote control software for the movement of the rigid frame at the BTF test beam. We are grateful to T. Napolitano and the SPCM service of LNF for the realisation of the mechanical supports used for the tests. Finally we acknoledge professor Y. Kudenko (INR-Moscow) for his fruitful suggestions. This project has received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 101004761. References [1] G. Bondarenko et al., Limited Geiger-mode microcell silicon photodiode: New results,Nucl. Instrum. Meth. A 442 (2000) 187. [2] F. Simon, C. Soldner and C. Joram, Direct coupling of SiPMs to scintillator tiles for imaging calorimetry and triggering, in proceedings of the IEEE Nuclear Science Symposuim & Medical Imaging Conference, Knoxville, TN, U.S.A., 30 October–6 November 2010, pp. 1703–1706 [arXiv:1011.5033]. – 22 – 2022 JINST 17 P01038 [3] O. Pooth, T. Radermacher, S. Weingarten and L. Weinstock, Scintillator tiles read out with silicon photomultipliers,2015 JINST 10 T10007. [4] S.H. Chang, D.H. Kim, M.A. Khan, D.J. Kong, J.S. Suh and Y.D. Oh, Production of extruded fine scintillator strips,J. Korean Phys. Soc. 53 (2008) 3178. [5] W. Baldini et al., SHADOWS (Search for Hidden And Dark Objects With the SPS), arXiv:2110.08025. [6] Y.G. Kudenko, L.S. Littenberg, V.A. Mayatsky, O.V. Mineev and N.V. Ershov, Extruded plastic counters with WLS fiber readout,Nucl. Instrum. Meth. A 469 (2001) 340. [7] B. Buonomo, C. Di Giulio, L.G. Foggetta and P. Valente, A hardware and software overview on the new BTF transverse profile monitor, in Proceedings of the 5th International Beam Instrumentation Conference, Barcelona, Spain, 11–15 September 2016, pp. 818–821. [8] Particle Data Group collaboration, Review of Particle Physics,PTEP 2020 (2020) 083C01. [9] T.T. Böhlen, F. Cerutti, M.P.W. Chin, A. Fassò, A. Ferrari, P.G. Ortega et al., The FLUKA Code: Developments and Challenges for High Energy and Medical Applications,Nucl. Data Sheets 120 (2014) 211. [10] V. Vlachoudis, Flair: A powerful but user friendly graphical interface for FLUKA, in proceedings of the International Conference on Mathematics, Computational Methods & Reactor Physics, Saratoga Springs, NY, U.S.A., 3–7 May 2009. – 23 –