scieee AI-readable full text Open interactive document viewer

Piezoelectric Surgery in Oral and Maxillofacial Procedures: A Contemporary Review

Ravichandran, Vigneshwaran; T S, Balaji; V, Yuvaraj; Kumar P, Suresh; P, Ashwini

Abstract

Piezoelectric surgery has emerged as a transformative tool in oral and maxillofacial surgery. Unlike traditional cutting instruments, piezoelectric devices utilize ultrasonic micro-vibrations to selectively incise mineralized tissues while sparing soft tissue structures. This innovative technology has been shown to improve safety, precision, and healing outcomes in procedures such as implantology, sinus augmentation, bone harvesting, and orthognathic surgery. Piezoelectric systems function using high-frequency ultrasonic vibrations (typically 25–30 kHz) that enable micrometric bone cutting with enhanced control and minimal trauma. The ability to cut hard tissues while preserving soft tissues provides a major advantage in areas near critical anatomical structures such as nerves and blood vessels. The technique also reduces intraoperative bleeding and postoperative complications, leading to better healing and patient comfort. Furthermore, piezosurgery improves visibility in the surgical field by minimizing blood loss. Although the equipment cost and longer surgical duration are potential drawbacks, the overall benefits including improved precision, safety, and biological response make it a valuable asset in modern oral and maxillofacial surgical procedures. This review presents a comprehensive evaluation of the principles, instrumentation, biological effects, clinical indications, and limitations of piezosurgery, with evidence based comparisons to conventional techniques.

Full text

 Corresponding author: Vigneshwaran R Copyright © 2025 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution License 4.0. Piezoelectric Surgery in Oral and Maxillofacial Procedures: A Contemporary Review Vigneshwaran Ravichandran *, Balaji T S, Yuvaraj V, Suresh Kumar P and Ashwini P Sri Venkateshwaraa Dental College and Hospitals, Pondicherry. Affiliated by Pondicherry University. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 Publication history: Received on 23 August 2025; revised on 06 October 2025; accepted on 09 October 2025 Article DOI: https://doi.org/10.30574/wjarr.2025.28.1.3102 Abstract Piezoelectric surgery has emerged as a transformative tool in oral and maxillofacial surgery. Unlike traditional cutting instruments, piezoelectric devices utilize ultrasonic micro-vibrations to selectively incise mineralized tissues while sparing soft tissue structures. This innovative technology has been shown to improve safety, precision, and healing outcomes in procedures such as implantology, sinus augmentation, bone harvesting, and orthognathic surgery. Piezoelectric systems function using high-frequency ultrasonic vibrations (typically 25–30 kHz) that enable micrometric bone cutting with enhanced control and minimal trauma. The ability to cut hard tissues while preserving soft tissues provides a major advantage in areas near critical anatomical structures such as nerves and blood vessels. The technique also reduces intraoperative bleeding and postoperative complications, leading to better healing and patient comfort. Furthermore, piezosurgery improves visibility in the surgical field by minimizing blood loss. Although the equipment cost and longer surgical duration are potential drawbacks, the overall benefits including improved precision, safety, and biological response make it a valuable asset in modern oral and maxillofacial surgical procedures. This review presents a comprehensive evaluation of the principles, instrumentation, biological effects, clinical indications, and limitations of piezosurgery, with evidence based comparisons to conventional techniques. Keywords: Piezoelectric device; Ultrasonic bone surgery; Maxillofacial surgery; Alveolar bone surgery; Sinus lift; Selective bone cutting 1 Introduction The evolution of minimally invasive surgical techniques has emphasized precision and tissue preservation. Piezoelectric surgery, introduced by Vercellotti in 1988, employs ultrasonic vibrations in the 25–30 kHz range to perform micrometric bone cutting while avoiding injury to adjacent soft tissues such as blood vessels, nerves, and mucosa1. The device consists of a cutting edge piezoelectric ultrasonic transducer mechanized by an ultrasonic generator competent of driving a range of resonant cutting inserts, a hand piece, and a foot switch connected to the main unit which supplies power and has holders for the hand piece and irrigation fluids2,3. It contains a peristaltic pump for cooling with a jet of solution that discharge from the inserts and also helps in removing rubble from the cutting area. The device has a control panel with a digital display to set the power and frequency modulation4. They also have several autoclavable tool-tips called inserts, which are titanium or diamond coated in various grades and move by microvibrations created in piezoelectric hand piece5.This device is widely used in dentistry serving various applications such as root planing, removal of supra and subgingival deposits and stains from teeth, crown lengthening, atraumatic tooth extraction, ridge augmentation, sinus floor elevation, bone graft harvesting, lateralization of inferior alveolar nerve, implant surgery, and ridge expansion6. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1509 1.1 History The term “piezo” originates from the Greek word piezein, which means, “to press tight, squeeze.” Jacques and Pierre Curie first discovered piezoelectricity in the year 1880 who found that applying pressure on various crystals, ceramics, or bone created electricity7-9. Gabriel Lippmann in 1881 found the converse piezoelectric effect, which was further investigated by various scientists. Mcfall et al., in 1961, evaluated the distinction of healing by comparison of rotating instruments and oscillating scalpel blade and found slow healing with no severe complication by use of these scalpel blades10. In 1980, Horton et al. stated that bone regeneration was better using ultrasonic device11. One year later, he evaluated the clinical utility of ultrasonic instrumentation in surgical removal of bone and observed mineralized tissue removal with ease and efficiency along with good acceptance by patients without any complications12. In 1998, Torella reported the better use of ultrasonic generator compared to magnetostrictive device because of its greater efficiency of cutting with less bone destruction13. In 1999, Dr. Thomas Vercelloti invented piezoelectric bone surgery in collaboration with Mectron Spa and published in the year 200014. In 2001, Piezosurgery was introduced. In 2002, the device was approved for commercial use in Germany. In 2003, Vercelloli discovered the ideal frequency method for endodontic, orthopedic, neurologic, periodontal, and oral and maxillofacial surgeries15,16. In 2005, the US Food and Drug Administration extended the use of ultrasonics in dentistry to include bone surgery17. 2 Mechanism of action • Piezosurgery operates on the principle of the piezoelectric effect, a phenomenon first identified by Jean and Marie Curie in 18803. At its core is ultrasonic transduction, generated by the contraction and expansion of piezoelectric ceramic elements. These vibrations are amplified and transmitted to the surgical tip, which, with gentle pressure and irrigation, selectively cuts mineralized tissues. Micro-streaming and cavitation are key advantages. • Cavitation is a microboiling process at the solid–liquid interface under ultrasonic frequencies, forming vapor bubbles that implode, releasing energy for cutting and cleaning. Micro-streaming is the swirling of fluid around the vibrating tip, improving debris removal and visibility. Cavitation also promotes microcoagulation, reducing bleeding by causing bubble implosion and thrombus formation in small vessels. • Selective cutting allows precise bone incisions while minimizing soft tissue damage, reducing bleeding. The handpiece connects to a central unit with a sterile irrigation system (0–60 ml/min) and footswitch activation. Tips vary in shape and design—sharp, serrated, and diamond-coated—for targeted anatomical use. • Electric current deforms piezoelectric crystals, producing cutting–hammering micro-movements at 25–29 kHz with 60–210 μm³ amplitude for powerful, precise cutting. • Ultrasonic scalers, operating at 24–36 kHz, use similar piezoelectric principles to remove plaque and calculus by transmitting longitudinal vibrations for bone cutting via microscopic shattering. 2.1 Wave propagation Ultrasonic testing relies on time-dependent deformations or vibrations in materials, categorized under acoustics. Materials consist of atoms that can vibrate around equilibrium positions, but acoustics focuses on collective particle motion generating mechanical waves. Under elastic stress, particles oscillate due to restoring electrostatic forces and inertia, enabling wave propagation. In solids, sound waves travel as longitudinal, shear (transverse), surface, or plate waves. Longitudinal and shear waves are commonly used. In longitudinal waves, particles vibrate parallel to wave direction, causing compression and expansion. Shear waves involve perpendicular particle motion and are weaker, typically generated by redirecting energy from longitudinal waves. 2.2 Piezoelectric transducer Ultrasonic testing is based on converting electrical energy into mechanical vibrations and vice versa, a function performed by the active element in an ultrasonic transducer. This element, typically made of polarized material with electrodes, undergoes electrostriction when an electric field causes molecular realignment and dimensional change. Permanently polarized materials like quartz (SiO₂) or barium titanate (BaTiO₃) exhibit the piezoelectric effect, generating electric fields when mechanically deformed. Modern transducers use piezoelectric ceramics due to their efficiency, shape flexibility, and thermal resistance up to 300°C. Barium titanate was first widely used, followed by lead zirconate titanate (PZT), now the standard material. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1510 2.3 Characteristics of piezoelectric transducers Ultrasonic testing relies on converting electrical energy into mechanical vibrations and vice versa, occurring in the active element of the ultrasonic transducer. This element, made of polarized material with electrodes, enables bidirectional transformation. When voltage is applied, molecular alignment induces dimensional change— electrostriction. Permanently polarized materials like quartz (SiO₂) or barium titanate (BaTiO₃) exhibit the piezoelectric effect, generating electrical signals upon mechanical deformation. Modern transducers use piezoelectric ceramics for their strong piezoelectric properties, manufacturability, and temperature resistance up to 300°C. Barium titanate was the first widely used ceramic, followed by PZT compounds, which dominate today. Some still call the element the “crystal.” 2.4 Cavitation Cavitation refers to a microboiling phenomenon that occurs in liquids at any solid–liquid interface subjected to intermediate-frequency vibrations. This process involves the disruption of molecular cohesion within the liquid, leading to the formation of low-pressure zones. These zones gradually fill with vapour, resulting in the development of microbubbles that are on the verge of implosion. In the context of detartrating (scaling) instruments, cavitation takes place when the water spray interacts with the ultrasonically vibrating insert, typically operating at intermediate frequencies. This effect contributes to both the cleaning action and enhanced visibility during dental procedures. 3 Instrumentation A piezoelectric unit comprises: - Main console with digital controls to adjust power, frequency, and irrigation rate. • -Handpiece containing piezoceramic transducers. - Tips/Inserts: Over 50 types are available, classified as sharp, blunt, or smooth, with specific applications such as osteotomy (OT7), sinus lift (EL1), and periodontal therapy. - Peristaltic pump: Delivers sterile saline at variable rates (up to 60 mL/min) for cooling and cavitation effects. Insert tips vary in design and coating (e.g., titanium nitride or diamond), enhancing their specificity and efficiency. Customized kits are now developed for sinus elevation, lateral osteotomy, and implant site preparation, increasing clinical versatility. 4 Biological effects of bone cut by piezoelectric device The mechanical instrument’s effect on bone structure and cell viability is critical in regenerative surgery. Factors like cortical/cancellous bone response and surface roughness from different osteotomy techniques significantly influence healing21. In piezoelectric osteotomy, cutting speed is adjustable based on indication and tissue condition by modulating frequency and amplitude. Its low-amplitude cutting enables precision. A blood-free surgical site, offering improved visibility, may result from local overheating, coolant flow, cavitation, or intravascular thrombosis22. A study comparing piezoelectric (PS) and rotating drills (RD) for harvesting autogenous bone chips showed similar cell viability and differentiation. Outgrowth of osteoblast-like cells was observed in 88.9% (RD) and 87.9% (PS) samples, confirmed by alkaline phosphatase and osteocalcin staining. PS samples had larger particle size, but both techniques yielded biologically effective chips23. Another study assessed microbiological profiles of bone debris collected during piezosurgery and tested rifamycin SV’s decontamination efficacy. Debris collected from 10 patients via bone trap showed that rifamycin significantly reduced bacterial contamination. In periodontal resective surgery on dogs, piezosurgery (PS) was compared with carbide (CB) and diamond burs (DB). By day 14, CB/DB sites showed bone loss, while PS sites had bone gain. At day 56, PS-treated sites continued bone gain, while CB/DB sites showed renewed bone loss, favoring PS for healing and remodeling24,25. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1511 A study on mini-pigs showed improved osseointegration and lower inflammatory response with piezoelectric surgery compared to traditional drilling. PS sites had earlier increases in BMP-4 and TGF-β2, and reduced inflammatory cytokines. Sonke Harder et al. compared three ultrasonic bone surgery devices. Piezosurgery II and Piezotome showed higher cutting performance than SurgySonic, with Piezotome producing the lowest intraosseous temperature increase, indicating effective and safe cutting. 5 Clinical applications 5.1 Dento-alveolar procedures Piezosurgery offers distinct advantages in procedures requiring precise manipulation of small bone segments or tooth fragments—such as tooth sectioning or retrieval of a fractured wisdom tooth that lies close to critical anatomical structures26-28 5.2 Tooth Extraction Used in ankylosed or impacted teeth, allowing conservative removal with preservation of alveolar bone29-31. 5.3 Implant Site Preparation Improves precision in osteotomy, especially near the inferior alveolar nerve, and enhances implant stability32. 5.4 Alveolar ridge splitting piezoelectric surgery simplifies vertical and horizontal ridge-splitting procedures. It allows precise cuts without generating heat-induced bone necrosis and significantly reduces the likelihood of damage to surrounding soft tissues. Vertical or horizontal incisions of any shape can be made safely and accurately without harming adjacent structures. Additionally, the cavitation effect created during the procedure helps keep the surgical field clean, enhancing visibility33. 5.5 Sinus Lift Procedures The cavitation effect helps in safely elevating the Schneiderian membrane without perforation. 5.6 Bone Harvesting Offers controlled harvesting of intraoral autogenous bone with reduced donor site morbidity and improved graft quality34,35. 5.7 Orthognathic Surgery Used in Le Fort I, II, III osteotomies, zygomatic reduction, and BSSO with reduced risk of nerve injury. 5.8 Periodontal and Periapical Surgery Enables controlled debridement, root planing, and bone contouring36,37. 5.9 Nerve Lateralization Safe for displacement of inferior alveolar nerve during implant procedures38,39. 5.10 Aesthetic facial surgery In aesthetic facial surgery, especially rhinoplasty, precise lateral osteotomy is crucial to minimize complications like ecchymosis and edema. Traditional chisels, often unguarded and used blindly, can transmit excessive force, risking injury to nasal soft tissues, damaging vessels like the angular artery, and increasing bleeding and periorbital ecchymosis40-43. 5.11 Distraction osteogenesis Precision is essential during osteotomies for distraction, especially in regions near dental roots, periodontal structures, and vascularized soft tissues. The micrometric and linear vibrations of piezosurgery allow for extremely accurate bone cutting while minimizing trauma to surrounding hard and soft tissues. This precision enables surgeons to perform osteotomies without harming the flap, thus preserving vascular supply essential for optimal new bone formation44,45. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1512 5.12 Temporomandibular Joint (TMJ) Surgery Piezosurgery also shows promise in the complex field of TMJ surgery, particularly in cases of TMJ ankylosis. Conditions like ankylosis often involve distorted anatomy, extensive bone remodeling, and proximity to sensitive structures like the maxillary artery. The various advantages of piezoelectric surgery allow for safer and more effective condylectomies46,47. 6 Advantages and limitations The key benefits of using piezosurgery in oral and maxillofacial procedures include : • Enhanced visibility of the surgical site, owing to pressurized irrigation and the cavitation effect. • Effective haemostasis achieved through the cavitation mechanism. • Precise bone cutting with micrometric accuracy. • Minimization of the risk of injury to surrounding soft tissues during hard tissue manipulation. • Accelerated healing, as the technique preserves living bone and stimulates morphogenetic protein release. • Simplified harvesting of autogenous bone grafts from intraor extra-oral sources; the variety of angled inserts allows access to hard-to-reach areas. • Absence of macro-vibrations ensures greater comfort for patients undergoing procedures under local anaesthesia. Despite its advantages, piezosurgery has some limitations : • It is contraindicated in patients with cardiac pacemakers. • The initial cost of the equipment can be a financial concern. • Surgical procedures may take longer when using piezosurgery. • Clinicians may require additional training and practice to become proficient in its use for oral and maxillofacial surgeries 6.1 Comparative evidence Compared to rotary and oscillating saws, piezosurgery demonstrates: • Less heat generation, preserving bone vitality • Lower incidence of membrane perforation • Fewer postoperative complications Meta-analyses and RCTs confirm improved patient-reported outcomes in terms of pain, healing time, and satisfaction4863. 7 Future of piezoelectric device The future of piezoelectric surgery is poised for transformative growth, with innovations aimed at enhancing precision, usability, and integration with digital technologies. 7.1 Integration of Smart Technologies One of the most promising developments is the incorporation of smart technology into piezosurgery systems. Potential features include: • AI-assisted navigation and feedback systems for real-time intraoperative guidance • Enhanced safety and precision through automated parameter adjustments • Minimized human error and improved outcomes through digital decision support These advancements are expected to streamline surgical workflows and increase the reliability of complex procedures64-67. 7.2 Ergonomics and Accessibility World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1513 Future piezosurgery devices are likely to be: • More ergonomically designed, reducing surgeon fatigue during lengthy procedures • Wireless or cordless, improving maneuverability • More customizable, allowing for tailored settings based on patient-specific or procedural requirements Such user-friendly enhancements will broaden the scope of application and increase the adoption of piezosurgery across clinical settings68,69. 7.3 Advancements in Ultrasonic Technology Ongoing research is aimed at refining ultrasonic precision and minimizing invasiveness even further. Expected innovations include: • Ultra-fine oscillation tips for microsurgical applications • Improved cavitation dynamics for cleaner cuts with less collateral tissue damage • Faster healing due to reduced cellular trauma and enhanced biocompatibility of new tool coatings These developments may lead to novel surgical protocols, enabling procedures that were previously not feasible with traditional instruments70,71. 8 Conclusion The advent of piezoelectric surgery has heralded a paradigm shift in dental and maxillofacial surgical practices, offering a compelling alternative to conventional mechanical instrumentation. With its hallmark features—selective cutting, micrometric precision, and minimal trauma to soft tissues—piezoelectric technology has significantly enhanced both surgical accuracy and patient safety. From implantology and periodontology to bone grafting and orthognathic procedures, its applications have transformed clinical workflows and postoperative outcomes, fostering a more patientcentered surgical approach. Looking ahead, the future of piezoelectric surgery appears promising, driven by continuous innovations in ultrasonic modulation, digital interfacing, and ergonomic refinement. The integration of artificial intelligence, real-time feedback systems, and robotics could further elevate its precision and adaptability. As these advancements materialize, piezoelectric instruments will not only evolve as surgical tools but also stand as emblems of modern dental innovation— redefining procedural standards and reinforcing the commitment to minimally invasive, high-performance care. References [1] Rashad A, Kaiser A, Prochnow N, Schmitz I, Hoffmann E, Haurer P. Heat Production during different Ultrasonic and conventional osteotomy preparation for dental Implants. Clin Oral Implant Res. 2011;22:1361–5. [2] Chopra P, Chopra P. Piezosurgery and its applications in Periodontology and Implantology. Int J ContempDent. 2011;2:16–24. [3] Pavlikova G, Foltan R, Horka M, Hanzelka T, BrounskaH, Sedy J. Piezosurgery in oral and maxillofacial surgery. Int J Oral Maxillofac Surg. 2011;40:451–7. [4] Labanca M, Azzola F, Vinci R, Rodella LF. Piezoelectric surgery: Twenty years of use. Br J Oral MaxillofacSurg. 2008;46:265–9. [5] Georg E, Klein J, Bank J, Hassfeld S. Piezosurgery: An ultrasound device for cutting bone and its use and limitations in maxillofacial surgery. Br J Oral MaxillofacSurg. 2004;42:451. [6] Nalbandian S. Piezosurgery techniques in implant dentistry. Aust Dent Pract. 2011: 116–26. [7] Catuna MC. Sonic Surgery. Ann Dent. 1953;12:100–29. [8] Richman MJ. The use of ultrasonics in root canal therapy and root resection. Med Dent J. 1957;12:12–8. [9] Mazarow HB. Bone repair after experimentally produced defects. J Oral Surg. 1960;18:107–15. [10] Mcfall TA, Yamane GM, Burnett GW. Comparison of cutting effect on bone of ultrasonic cutting device and rotary burs. J Oral Surg. 1961;19:200–9. World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1514 [11] Horton JE, Tarpley TM, Wood LD. The healing of surgical defects in alveolar bone produced with ultrasonic instrumentation, chisel and rotary bur. Oral Surg. 1975;39: 536–46. [12] Horton JE, Tarpley TM, Jr, Jacoway JR, Chapel Hill NC. Clinical applications of ultrasonic instrumentation in the surgical removal of bone. Oral Surg Oral Med Oral Pathol. 1981;51:236–42. [13] Torrella F, Pitarch J, Cabanes G, Aniuta E. Ultrasonic osteotomy for surgical approach of maxillary sinus: A technical note. Int J Oral MaxillofacImplants. 1998;13:697–700. [14] Vercellotti T. Piezoelectric surgery in implantology: A case report – A new piezoelectric ridge expansion technique. Int J Periodont Restorative Dent. 2000;20: 359–65. [15] Walsh LJ. Piezosurgery: An increasing role in dental hard tissue surgery. Aust Dent Pract. 2007;18:52–6. [16] Pereira CC, Gealh WC, Meorin-Nogueira L, Garcia-Júnior IR, Okamoto R. Piezosurgery Applied to Implant Dentistry: Clinical and Biological Aspects. J Oral Implantol. 2014;40:401–8. [17] Thomas J. piezoelectric ultrasonic bone surgery: Benefits for the interdisciplinary team and patients. Dent India. 2008;2:20–4. [18] Kshirsagar JT, Prem KK, Yashodha SR, Nirmmal MT. Piezosurgery: Ultrasonic bone surgery in periodontics and oral implantologyReview. Int J Appl Dent Sci. 2015;1: 19–22. [19] Leclercq P, Zenati C, Amr S, Dohan DM. Ultrasonic bone cut part 1: State-of-art technologies and common applications. J Oral Maxillofac Surg. 2008;66:177–82. [20] Aro H, Kallioniemi H, Aho AJ, Kellokumpu-Lehtinen P. Ultrasonic Device in Bone Cutting. A Histological and Scanning Electron Microscopical Study. Acta OrthopScand. 1981;52:5–10. [21] Mani AM, Marawar PP, Shubhangi Amit, Dalvi A. Piezosurgery – A Review. Pravara Med Rev. 2014;6:8–11. [22] Agarwal E, Masamatti SS, Kumar A. Escalating Role of Piezosurgery in Dental Therapeutics. J Clin Diagn Res. 2014;8:ZE08–11. [23] Devi S, Swaminathan M, Karthikeyan I, Anitha K. Piezosurgery in Periodontics. Int J ProsthodontRestorative Dent. 2015;5:51–5. [24] Schlee M. Piezosurgery – A precise and safe new oral surgery technique. Aust Dent Pract. 2009;2009:144–8. [25] Lands CA, Stubinger S, Laudemann K, Rieger J, SaderR. Bone harvesting at the anterior iliac crest using piezoosetotmy versus conventional open harvesting: A pilot study. Oral Surg Oral Med Oral Pathol Oral Radio Endod. 2008;105:19–28. [26] K. Schwieger, V. Carrero, R. Rentzsch, A. Becker, N. Bishop, E. Hille, et al. Abrasive water jet cutting as a new procedure for cutting cancellous bone-in vitro testing in comparison with the oscillating saw J Biomed Mater Res B Appl Biomater, 71 (2) (2004), pp. 223-228 [27] S.J. Lee, K.H. Park Ultrasonic energy in endoscopic surgery Yonsei Med J, 40 (1999), pp. 545-549 [28] J.E. Horton, T.M. Tarpley Jr., J.R. Jacoway Clinical applications of ultrasonic instrumentation in the surgical removal of bone Oral Surg Oral Med Oral Pathol, 51 (1981), pp. 236-242 [29] G. Eggers, J. Klein, J. Blank, S. Hassfeld Piezosurgery: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgery Br J Oral MaxillofacSurg, 42 (2004), pp. 451-453 [30] T. Vercellotti Technological characteristics and clinical indications of piezoelectric bone surgery Minerva Stomatol, 53 (2004), pp. 207-214 [31] D.J. Hoigne, S. Stubinger, O. VonKaenel, S. Shamdasani, P. Hasenboehler Piezoelectic osteotomy in hand surgery: first experiences with a new technique BMC MuscoskelDisord, 7 (2006), p. 36 [32] T. Vercellotti Essentials in piezosurgery. Clinical advantages in dentistry (first ed.), QuintessenzaEdizioni, Milan (2009), pp. p65-107 [33] T. Vercellotti, S. De Paoli, M. Nevins The piezoelectric bony window osteotomy and sinus membrane elevation: introduction of a new technique for simplification of the sinus augmentation procedure Int J Periodontics RestorDent, 21 (2001), pp. 561-567 [34] S. Claire, S.C. Lea, A.D. Walmsley Characterisation of bone following ultrasonic cutting Clin Oral Invest, 17 (3) (2013), pp. 905-912 World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1515 [35] A. HappeUse of a piezoelectric surgical device to harvest bone grafts from the mandibular ramus: report of 40 cases Int J Periodontics Restor Dent, 27 (2007), pp 241-249 [36] D.S. Sohn, M.R. Ahn, W.H. Lee, D.S. Yeo, S.Y. LimPiezoelectric osteotomy for intraoral harvesting of bone blocks Int J Periodontics Restor Dent, 27 (2007), pp. 127-131 [37] M. Berengo, C. Bacci, M. Sartori, A. Perini, M. DellaBarbera, M. Valente Histomorphometric evaluation of bone grafts harvested by different methods Minerva Stomatol, 55 (2006), pp. 189-198 [38] S. Stubinger, A. Robertson, K.S. Zimmerer, C. Leiggener, R. Sader, C. Kunz Piezoelectiric harvesting of an autogenous bone graft from the zygomaticomaxillary region: case reportInt J Periodontics RestorDent, 26 (2006), pp. 453-457 [39] S. Sivolella, M. Berengo, E. Bressan, A. Di Fiore, E. Stellini Osteotomy for lower third molar germectomy: randomized prospective crossover clinical study comparing piezosurgery and conventional rotatory osteotomyJ Oral Maxillofac Surg, 69 (2011), pp. e15-23 [40] E. Mantovani, P.G. Arduino, G. Schierano, L. Ferrero, G. Gallesio, M. Mozzati, et al.A split-mouth randomized clinical trial to evaluate the performance of piezosurgerycompared with traditional technique in lower wisdom tooth removal J Oral Maxillofac Surg, 72 (10) (2014), pp. 1890-1897 [41] N.C. Gellrich, U. Held, R. Schoen, T. Pailing, A. Schramm, K.H. Bormann ,Alveolar zygomatic buttress: a new donor site for limited preimplant augmentation procedures, J Oral Maxillofac Surg, 65 (2007), pp. 275-280 [42] L. Lamazza, D. Laurito, M. Lollobrigida, O. Brugnoletti, G. Garreffa, A. De Biase, Identification of possible factors influencing temperatures elevation during implant site preparation with piezoelectric technique Ann Stomatol, 5 (2015), pp. 115-122, [43] F. Heinemann, I. Hasan, C. Kunert-Keil, et al.Experimental and histological investigations of the bone using two different oscillating osteotomy techniques compared with conventional rotary osteotomy Ann Anat, 194 (2012), pp. 165-170 [44] S. Pelo, R. Boniello, G. Gasparini, G. Longobardi, P.F. AmorosoHorizontal and vertical ridge augmentation for implant placement in the aesthetic zone Int J Oral Maxillofac Surg, 36 (10) (2007), pp. 944-948 [45] D. Buser, K. Dula, U. Belser, H.P. Hirt, H. BertholdLocalized ridge augmentation using guided bone regeneration. Surgical procedure in the maxilla Int J Periodontics Restor Dent, 13 (1) (1993), pp. 29-45 [46] D. Buser, K. Dula, U. Belser, H.P. Hirt, H. BertholdLocalized ridge augmentation using guided bone regeneration. II. Surgical procedure in the mandible Int J Periodontics Restor Dent, 15 (1) (1995), pp. 10-29 [47] T. Takahashi, K. Funaki, H. Shintani, T. Haruoka Use of horizontal alveolar distraction osteogenesis for implant placement in a narrow alveolar ridge: a case reportInternational Journal of Oral and Maxillofacial Implants, 19 (2) (2004), pp. 291-294. [48] Jesudasan JS, Wahab PU, Sekhar MR. Effectiveness of 0.2% chlorhexidine gel and a eugenol-based paste on postoperative alveolar osteitis in patients having third molars extracted: a randomised controlled clinical trial. Br J Oral Maxillofac Surg. 2015;53: 826–30. [49] Arteagoitia MI, Barbier L, Santamaria J, Santamaria G, Ramos E. Efficacy of amoxicillin and amoxicillin/clavulanic acid in the prevention of infection and dry socket after third molar extraction. A systematic review and metaanalysis. Med Oral Patol Oral Cir Bucal. 2016;21:e494–504. [50] Majid OW, Mahmood WK. Effect of submucosal and intramuscular dexamethasone on postoperative sequelae after third molar surgery: comparative study. Br J Oral Maxillofac Surg. 2011;49:647–52. [51] Koyuncu BO, Zeytinoglu M, Tetik A, Gomel MM. Effect of tube drainage compared with conventional suturing on postoperative discomfort after extraction of impacted mandibular third molars. Br J Oral MaxillofacSurg. 2015;53:63–7. [52] Siroraj AP, Giri GVV, Ramkumar S, Narasimhan M. Extraction of impacted mandibular third molars - the effect of osteotomy at two speeds on peripheral bone: a histopathological analysis. Br J Oral MaxillofacSurg. 2016;54:449– 53. [53] Bennardo F, Barone S, Vocaturo C, Nucci L, Antonelli A, Giudice A. Usefulness of Magnetic Mallet in Oral Surgery and Implantology: A Systematic Review. J Pers Med. 2022;12 World Journal of Advanced Research and Reviews, 2025, 28(01), 1508-1516 1516 [54] Cosola S, Kim YS, Park YM, Giammarinaro E, CovaniU. Coronectomy of Mandibular Third Molar: Four Years of Follow-Up of 130 Cases. Medicina (Kaunas) 2020;56 [55] Badenoch-Jones EK, David M, Lincoln T. Piezoelectric compared with conventional rotary osteotomy for the prevention of postoperative sequelae and complications after surgical extraction of mandibular third molars: a systematic review and meta-analysis. Br J Oral Maxillofac Surg. 2016;54:1066–79. [56] Bhati B, Kukreja P, Kumar S, Rathi VC, Singh K, Bansal S. Piezosurgery versus Rotatory Osteotomy in Mandibular Impacted Third Molar Extraction. Ann Maxillofac Surg. 2017;7 [57] Liu J, Hua C, Pan J, Han B, Tang X. Piezosurgery vs conventional rotary instrument in the third molar surgery: A systematic review and meta-analysis of randomized controlled trials. J Dent Sci. 2018;13:342–9. [58] Piersanti L, Dilorenzo M, Monaco G, Marchetti C. Piezosurgery or conventional rotatory instruments for inferior third molar extractions? J Oral Maxillofac Surg. 2014;72:1647–52. [59] Bassi F, Cicciu M, Di Lenarda R, Galindo Moreno P, Galli F, Herford AS. Piezoelectric bone surgery compared with conventional rotary instruments in oral surgery and implantology: Summary and consensus statements of the International Piezoelectric Surgery Academy Consensus Conference 2019. Int J Oral Implantol (Berl) 2020 ; 13: 235 –9. [60] Al-Moraissi EA, Elmansi YA, Al-Sharaee YA, AlrmaliAE, Alkhutari AS. Does the piezoelectric surgical technique produce fewer postoperative sequelae after lower third molar surgery than conventional rotary instruments? A systematic review and meta analysis. Int J Oral Maxillofac Surg. 2016;45:383–91. [61] Goyal M, Marya K, Jhamb A, Chawla S, Sonoo PR, Singh V. Comparative evaluation of surgical outcome after removal of impacted mandibular third molars using a Piezotome or a conventional handpiece: a prospective study. Br J Oral Maxillofac Surg. 2012;50: 556 –61. [62] Menziletoglu D, Basturk F, Isik BK, Esen A. A prospective split-mouth clinical study: comparison of piezosurgery and conventional rotary instruments in impacted third molar surgery. Oral MaxillofacSurg. 2020;24:51–5. [63] Arakji H, Shokry M, Aboelsaad N. Comparison of Piezosurgery and Conventional Rotary Instruments for Removal of Impacted Mandibular Third Molars: A Randomized Controlled Clinical and Radiographic Trial. Int J Dent. 2016 [64] Klokkevold PR, Urban IA, Cochran DL. Surgical Concepts of Implant Therapy In: Clinical Periodontology (12th ed). New Delhi, India: Saunders, Elsevier; 2015. p. :697-723.e5. [65] Kshirsagar JT, Prem kumar K, Yashodha SR, Nirmmal MT. Piezosurgery: Ultrasonic bone surgery in periodontics and oral implantology-review. Int J Appl Dent Sci. 2015;1: 19-22. [66] Bhagat M, Tapashetti R, Fatima G. Piezosurgery in periodontics. Galore Int J Health Sci Res. 2020;5:121. [67] Thomas M, Akula U, Ealla KK. Piezosurgery: A boon for modern periodontics. J Int Soc Prev Community Dent. 2017;7:1-7. [68] Anuroopa P, Panikar GK, Nalini MS, Reddy BC. Piezosurgery in dentistry: A versatile tool in bone management. Res Rev J Dent Sci. 2014;2:32-7. [69] Yaman Z, Suer BT. Piezoelectric surgery in oral and maxillofacial surgery. Ann Oral Maxillofac Surg. 2013;1:1-9. [70] Pavlikova G, Foltan R, Horka M, Hanzelka T, Borunská H, Sedý J. Piezosurgery in oral and maxillofacial surgery. Int J Oral Maxillofac Surg. 2011;40:451-7. [71] Claire S, Lea SC, Walmsley AD. Characterisation of bone following ultrasonic cutting. Clin Oral Investig. 2013;17:905-12.