Diagnostics of hydrogen-containing mixture compression by a two-stage piston compressor with cooling demand prediction

Brestovič, Tomáš

Abstract

The present article describes the diagnostics of a compressor that is compressing a mixture of H-2 and N-2 on the basis of the results that were obtained by operational measurements of the flow rates and temperatures at selected compressor sites, as well as of the acoustic pressure levels during the full loading thereof. The obtained data were subsequently used to determine the limit conditions of the compressor operations in terms of the cooling capacity. A thermodynamic analysis of the compression of the H-2/N-2 gas mixture was carried out with subsequent heat and energy flow calculation and the determination of the minimum cooling water flow rate that is required to ensure the continuous compressor operations.

Full text

applied sciences Article Diagnostics of Hydrogen-Containing Mixture Compression by a Two-Stage Piston Compressor with Cooling Demand Prediction Tomáš Brestoviˇc 1, Mária ˇ Carnogurská1,*, Miroslav Pˇríhoda 2, Peter Lukáˇc 1, Marián Lázár1, Natália Jasminská1and Romana Dobáková1 1Department of Power Engineering, Faculty of Mechanical Engineering, Technical University of Košice, Vysokoškolská4, 042 00 Košice, Slovakia; [email protected] (T.B.); peter[email protected] (P.L.); [email protected] (M.L.); [email protected] (N.J.); [email protected] (R.D.) 2Department of Thermal Engineering, Faculty of Metallurgy and Materials Engineering, VŠB—Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava, Poruba, Czech Republic; miroslav[email protected] *Correspondence: [email protected]; Tel.: +421-55-602-4359 Received: 13 March 2018; Accepted: 10 April 2018; Published: 17 April 2018   Abstract: The present article describes the diagnostics of a compressor that is compressing a mixture of H 2 and N 2 on the basis of the results that were obtained by operational measurements of the flow rates and temperatures at selected compressor sites, as well as of the acoustic pressure levels during the full loading thereof. The obtained data were subsequently used to determine the limit conditions of the compressor operations in terms of the cooling capacity. A thermodynamic analysis of the compression of the H 2 /N 2 gas mixture was carried out with subsequent heat and energy flow calculation and the determination of the minimum cooling water flow rate that is required to ensure the continuous compressor operations. Keywords: compressor; diagnostics; operating experiment; minimum cooling capacity 1. Introduction Increased pressure within the society to use hydrogen technologies in the transport segment necessitates the search for solutions to partial problems regarding hydrogen production, as well as reduction of the energy consumption in the hydrogen production process. Along with these requirements, it is also necessary to solve hydrogen purification from undesired impurities [ 1 ] and the transformation of the chemical energy of the gas into electrical energy, for example, in fuel elements [ 2 ]. An important part of hydrogen technologies is also the efficient storage thereof at acceptable pressures [3]. For the purpose of hydrogen storage in the form of metal hydrides, the absorption pressure is decreased below 1 MPa. Compression of pure hydrogen or a hydrogen-containing mixture is carried out using positive-displacement compressors or centrifugal compressors. Compressor failures frequently occur in the real operation of compressors. Such failures are usually caused by insufficient cooling or by a fabrication-related fault of any of the compressor’s components. For several reasons, it is necessary to know the limits of a particular compressor in terms of its cooling capacity. The first reason is the manufacturer’s reputation with regard to marketing high-quality products that meet all of the operator’s requirements. The second reason is the financial loss that is incurred by the manufacturer if the device is faulty. The diagnostics of these machines and their parts is carried out using various apparatuses and technology. Currently, non-destructive measuring techniques are predominantly used; they are based on ultrasound waves [ 4 ] and vibrations [ 5 , 6 ]. Compressors are usually subjected to simplified tests Appl. Sci. 2018,8, 625; doi:10.3390/app8040625 www.mdpi.com/journal/applsci Appl. Sci. 2018,8, 625 2 of 15 with a shorter duration [ 7 ]. The examination of flow conditions, heat transfer, and the effect thereof on a compressor’s efficiency is carried out while applying, to a large extent, numerical methods that are based on the Finite Element Method or the Finite Volume Method [ 8 – 10 ]. Attention is also paid to oil retention in the compressor pipes, depending on the thickness of the oil film on the compressor surface [ 11 ]. The methods applied when dealing with non-equilibrium compressor states and while using the equation of the Lagrangian velocity-gradient correlation are discussed in [ 12 ]. With regard to the stable compressor operation, the issues regarding the hydrogen embrittlement on the surface of individual steel parts that is caused by hydrogenation are very important [13]. Following chapters describe the compression of a mixture of H 2 and N 2 by a two-stage compressor with the aim to quantify real heat transfer necessity for maintaining the stable operation of the device. 2. Measurement Methodology and Used Devices The Mehrer TZW 60/S6 (Mehrer Compression GmbH, Balingen, Germany) piston compressor is used for the compression of the mixture of 75% H 2 and 25% N 2 gases, from a relative pressure (overpressure) of 3 kPa to the max. relative pressure of 900 kPa. The two-stage compressor with an intercooler and an aftercooler of the gas mixture uses a central cooling system (Figure 1). Figure 1. Compressor connection diagram including the description of the measuring and regulation technology (1—Stage 1 of the compressor, 2—Stage 2 of the compressor, 3—intercooler, 4—aftercooler, 5—thermostatic regulating valve controlled by the TC1 sensor, 6—inlet filter, 7, 8—blow-down device, 9, 10—valves, 11—cooling water inlet valve, TC1—temperature sensor for the thermostatic regulation, PI1 to PI3—manometer, TR1 to TR8—temperature sensors with the recording of the SMT160-30 (Smartec BV, Breda, Netherlands), FR1—UTXDR ultrasound flow meter (GE, Waltham, MA, USA)). The water is also used to cool the compressor cylinders. Thermostatic regulation of the cooling water temperature ensures that the maximum temperature of the water at the outlet from the cylinders is maintained at the maximum value of 50 ◦ C. The cooling of the intercooler must be adjusted manually, using a regulating valve, so that the gas temperature at the inlet to Stage 2 is ≤ 45 ◦ C. The cooling water inlet to the aftercooler must be adjusted, using a regulating valve, so that the output gas temperature is as much as 5–20 ◦ C higher than the cooling water temperature. Specification of the used compressor of the TZW 60/S6 type, including the description of its borderline parameters, is contained in Table 1. Appl. Sci. 2018,8, 625 3 of 15 Table 1. Specification of the type TZW 60/S6 compressor. Parameter Value Maximum Pressure at the Outlet Maximum mass flow rate 900 kPa 17.5 g·s−1 Maximum gas pressure at the inlet 30 kPa Nominal output of the connected electric motor 22 kW Maximum cooling water temperature at the outlet from the compressor 50 ◦C Maximum compressor efficiency 59% During the measurement, the rate of the cooling water flow through the intercooler and the aftercooler was set so that the gas temperature at the inlet to Stage 2 of the compressor did not exceed 32 ◦ C, and so that the maximum difference between the gas temperatures at the outlet from the aftercooler and the temperature of the cooling water was 7.2 ◦C. Date of measurement: 19 July 2017. Measurements of the thermal and energy parameters were based on the calorimetric principle, as no phase transition of the liquid medium occurs while it is being transported through the individual compressor parts. The temperatures were measured using SMT160-30 smart temperature sensors (with the measurement accuracy of ± 0.4%) connected to the B-Pi microcomputer, with a pre-set measurement interval of 10 s at the following device points: •TR1—cooling water temperature at the inlet pipe behind the filter; • TR2—cooling water temperature at the outlet pipe (total cooling water temperature at the discharged from the compressor); •TR3—cooling water temperature at the outlet pipe from the cylinders; •TR4—cooling water temperature at the outlet pipe from the intercooler; •TR5—gas temperature at the inlet to Stage 1 of the compressor; •TR6—gas temperature at the outlet from Stage 1 of the compressor; •TR7—gas temperature at the inlet to Stage 2 of the compressor; and, •TR8—gas temperature at the outlet from Stage 2 of the compressor. During the measurement, the compressor was running in a regular operation (Figure 2), and the cooling water flow rate measurement was carried out using the ultrasonic flow meter (without any intervention in the cooling circuit). The type of the used flow meter: GE Transport PT878, UTXDR measuring probe (2 MHz) (GE, Waltham, MA, USA), measurement accuracy of ± 2%; pipe thickness measuring probe—Panametrics D868 (5 MHz) (GE, Waltham, MA, USA), and measurement accuracy of ± 5%. The connection of the UTXDR measuring probe of the flow meter to the cooling water inlet pipe is depicted in Figure 3. Figure 2. A view of the compressor during the experiment (1—B-Picomputer, 2—intercooler, 3—electric motor, 4—compressor body). Appl. Sci. 2018,8, 625 4 of 15 Figure 3. Connection of the flow meter at the cooling water inlet pipe (1—GE Transport PT878, 2—UTX DR measuring probe). The measured parameters included (in addition to the water flow rate Q Vw and temperatures t 1 to t 8 ): the electric motor rotation speed n; difference in pressures at the cooling water inlet and outlet ∆ p; relative gas pressure at the inlet, after Stages 1 and 2 of the compressor p; atmospheric pressure p at , electric current Ientering the three-phase SIEMENS 1MJ61864CA60 electric motor (Siemens AG, Mönch, Germany), connected in the delta connection, with the nominal power of 22 kW. During the measurement, the atmospheric pressure did not change and its value was 99.9 kPa. Curves of all the water and gas temperatures are shown in Figure 4. The temperature fluctuations in the terminal section of the graph are caused by adjusting the rate of flow into the intercooler and the terminal aftercooler using the regulating valves. Figure 4. Curves of the measured temperatures. The measurement was carried out using the compressor running in a stable operation. When the operating parameters were changed, it was necessary to maintain and stabilise the gas and the cooling water temperatures within a period of 3 to 36 min (depending on the severity of the change in the operating parameters). During the measurements, the operating conditions (inlet gas pressure, compressor revolutions, and cooling water flow rate) were deliberately changed to avoid the need for the long-term monitoring Appl. Sci. 2018,8, 625 5 of 15 of individual compressor parameters. After the stabilisation of the changed operating conditions, the monitored parameters were found to be of almost constant values. Such a procedure facilitated the shortening of the time interval that was necessary for the system diagnostics. All of the data presented in Figure 5and in the following figures represent the average values of ten consecutive measurements with the 10 s increments. Figure 5. Volume flow and the difference between the inlet and outlet cooling water pressures. The water flow rate (Q Vw ) and the values of differences in the pressures of the inlet water and heated water ( ∆ p), recorded at selected times, are shown in Figure 5. The increase in the pressure difference at the times 12:33 and 12:41 is caused by closing the water flow into the neighbouring compressors that were not running during the measurement, while the cooling water from the central cooling system was still flowing through them. This increase in the pressure difference was also reflected in an increased rate of the cooling water flow through the measured compressor. The pressure difference, as well as the total cooling water flow rate, is thus significantly dependent on the number of compressors connected to the cooling circuit, which can cause failures during the device operations. The measured relative gas pressure at the inlet to the compressor is shown in Figure 6. At 1:47 and 11:57, it was raised to the maximum allowable value for the purpose of an analysis of its impact on the compressor’s operating parameters. Figure 6. Relative gas pressure at the inlet to the compressor. Figure 7depicts the development of the relative pressure after the first and the second stages of the compressor. Appl. Sci. 2018,8, 625 6 of 15 Figure 7. Relative gas pressure after the first and second stages. Figure 8represents the measured average electric current that was flowing through the first stage into the electric motor. A comparison of Figures 6and 8clearly shows that the increase in the electric current becomes substantial mainly when the inlet gas pressure is elevated, which leads to an increase in the amount of compressed gas and thus also to an increase in the compression work. Figure 8. Average electric current flowing into the electric motor through one phase. The rated current for the used electric motor is 41 A, while the current protection device switches off the motor at a current of 43 A. This indicates that it is necessary to maintain the relative gas pressure at the inlet to the compressor at a maximum value of 10 kPa. The nominal relative output pressure is, according to the compressor technical data, 3 kPa. The motor rotation speed during the measured values ranged between the value of 1007 and the nominal value of 1460 min −1 (Figure 9). By increasing the revolutions up to the nominal value of 1460 min −1 , the electric current was increased. A correlation between the revolutions and the motor current cannot be identified, as the electric current depends on the mechanical power of the electric motor. A rapid increase of the input relative pressure (Figure 6) changes the parameters of technical output, as defined by Formulas (5) and (6). Concurrently, there is a change in the thermal power due to the changing temperatures and flow rates of cooling water, affecting thus output parameters in Formula (1). Appl. Sci. 2018,8, 625 7 of 15 Figure 9. Electric motor rotation speeds during the measurement. The measurement of the acoustic pressure level was carried out at the same conditions as stated in the compressor documentation (according to GAGI-PNEUROP): 1 m distance from the noise source; 1.5 m height from the floor. The measurement was carried out using the Norsonic 118 measuring device (measurement accuracy of ± 2.1 dB A , Gracey & Associates, Upper Dean, UK). The measurements were carried out at the same times as the measurements of the pressure, flow rate, and other parameters. They lasted 100 s with a sampling frequency of 8 Hz. Subsequently, the average acoustic pressure level Lwas determined. The measurement results are listed in Figure 10. The values do not exceed the maximum allowable level of acoustic pressure—80 dB A . The highest values were reached when the electric motor was running at the nominal rotation speed. Figure 10. Acoustic pressure levels. 3. Thermodynamic Analysis of the Compression of the Mixture of H2and N2Gases To define potential causes of the Mehrer TZW 60/S6 compressor failures, it is necessary to determine the energy flows in the gas mixture compression process. On the basis of the energy balance, by calculating individual powers, it will be possible to determine the minimum required amount of cooling water. The power that is required to cover the technical work (W T ) will hereinafter be referred to as the technical power (P TW ). The energy balance of the compressor is based on the assumption that the total supplied mechanical power of the electric motor is split into the technical power of the polytropic compression in Stages 1 and 2 and the thermal power released during the compression, as described by the formula: Pm=|PTW1|+|PTW2|+|Pts|, (1) where P m is the mechanical power of the electric motor (W), PTW1 is the technical power of Stage 1 of the compressor (W), PTW2 is the technical power of Stage 2 of the compressor (W), and P ts is the total thermal power of the compressor (including the heat loss) (W). Appl. Sci. 2018,8, 625 8 of 15 The mechanical power (Figure 11) on the shaft, supplied into the compressor, P m , can be determined by using the formula: Pm=3·I·Uz·cos ϕ·ηelm, (2) where Iis the average electric current flowing through one coil of the electric motor (A), U z is the line voltage (400 V), cos ϕ is the power factor (for the given electric motor it is 0.85), and ηelm is the electric motor efficiency (1). Figure 11. Calculated mechanical power on the electric motor shaft. When the electric motor is connected in the Delta connection, then the current flowing through a single coil connected to the line voltage is as follows: I=I1f ·1 √3, (3) where I 1f is the measured value of the electric current flowing into the electric motor through a single phase (A). The electric motor efficiency, calculated from the electric motor label data while using the Formula (4), is 91.1%: ηelm =Pmn 3·In·Uz·cos ϕ, (4) where P mn is the nominal mechanical power on the shaft (W), and I n is the nominal electric current flowing through a single coil when the electric motor is in the Delta connection (A). The technical power of the compressor Stages 1 and 2 is derived for the polytropic process of the compressor work [14,15]: PTW1 =Qm·n1 n1−1·r·T1· 1−p2 p1n1−1 n1 , (5) PTW2 =Qm·n2 n2−1·r·T3· 1−p3 p2n2−1 n2 , (6) where Q m is the mass flow rate of the mixture of H 2 and N 2 gases (kg · s −1 ), n 1 ,n 2 are the polytropic exponents of Sages 1 and 2 of the compressor (1), T 1 is the gas temperature at the inlet into Stage 1 of the compressor (K), T 3 is the gas temperature at the inlet into Stage 2 of the compressor (K), ris the specific gas constant of the mixture of the compressed gases (J · kg −1· K −1 ), p 1 is the absolute gas pressure at the inlet into Stage 1 of the compressor (Pa), p 2 is the absolute gas pressure at the outlet Appl. Sci. 2018,8, 625 9 of 15 from Stage 1 of the compressor (Pa), and p 3 is the absolute gas pressure at the outlet from Stage 2 of the compressor (Pa). The mass flow rate of the gas is: Qm=QV·ρ, (7) where Q V is the volumetric flow rate of the gas mixture at the inlet to the compressor (m 3· s −1 ), and ρ is the density of the gas mixture at the inlet to the compressor (kg·m−3). As the gas flow rate was not measured, its value was analytically obtained on the basis of the flow rate at the reference conditions (165 m 3· h −1 at 0 ◦ C and 101.325 kPa). The calculation of the volumetric flow rate of the gas at the inlet to Stage 1 of the compressor is derived, at the operational conditions, from the stated equation, while respecting the change in the compressor rotation speed. The compressibility factors of the gases are neglected when expressing the volumetric flow rate of the gas at the inlet to Stage 1 of the compressor, as they are approximately equal to 1 (at the pressure of 110 kPa and the temperature of 30 ◦ C it applies that z H2 = 1.00031, z N2 = 0.99956). Then, the following applies: QV=T1 Tn·pn p1·nc ncn ·QVn, (8) where T n is the gas temperature at standard conditions (273.15 K), p n is the pressure at standard conditions (101.325 kPa), n c is the compressor rotation speed (min −1 ), n cn is the nominal rotation speed of the compressor (min −1 ), and Q Vn is the rate of the gas flow through the compressor at standard conditions (m3·s−1). The gas mixture density was determined using the formula: ρ=∑p·xi T·ri , (9) where r i is the specific gas constant of the ith component (J · kg −1· K −1 ), and x i is the molar fraction of the ith component of the mixture (1). The calculated values of the mass flow rate of the gas that is flowing through the compressor are shown in Figure 12. Figure 12. Mass flow rate of the gas flowing through the compressor. The calculations of the polytropic exponents n1and n2were based on formulas: p2 p1=T2 T1n1 n1−1, (10) p3 p2=T4 T3n2 n2−1, (11)