scieee AI-readable full text Open interactive document viewer

Vibration energy signal information for measure dynamic preferences of ceramic building materials using experimental modal analysis methodology

Żółtowski, Mariusz

Abstract

Building constructions and their elements must meet requirements related to stability and strength. These are the conditions that determine the safety of the structure during both construction and operation. Safety assessment is based on diagnostic tests, aimed at checking the quality of the erected objects or locating damage to structural elements that arise during operation. This work focuses on experimental SISO modal analysis of ceramic masonry elements. An experiment was carried out on twenty samples of solid brick (good, and intentionally damaged). From this, it was possible to determine the variability of the obtained measurement results of the vibration characteristics of the masonry element, and, thus, to assess the value of the method used in the given research problem. The aim of this study was to test the effectiveness of assessing the degradation of the tested brick elements based on stabilization diagrams. The research confirmed the usefulness of experimental modal analysis in identifying damage to masonry elements, and it has been implemented in selected brickyards in Poland.

Full text

  Citation: ˙ Zółtowski, M.; Rutkowska, G.; Liss, M.; Kałaczy´nski, T.; Krejsa, M. Vibration Energy Signal Information for Measure Dynamic Preferences of Ceramic Building Materials Using Experimental Modal Analysis Methodology. Materials 2022,15, 1452. https://doi.org/ 10.3390/ma15041452 Academic Editors: Francesco Fabbrocino and Antonio Caggiano Received: 28 December 2021 Accepted: 10 February 2022 Published: 15 February 2022 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). materials Article Vibration Energy Signal Information for Measure Dynamic Preferences of Ceramic Building Materials Using Experimental Modal Analysis Methodology Mariusz ˙ Zółtowski 1,* , Gabriela Rutkowska 1, Michał Liss 2, Tomasz Kałaczy´nski 2and Martin Krejsa 3 1Institute of Civil Engineering, Warsaw University of Life Sciences (SGGW), 02-787 Warsaw, Poland; [email protected] 2Faculty of Mechanical Engineering, Bydgoszcz University of Science and Technology, 85-796 Bydgoszcz, Poland; [email protected] (M.L.); [email protected] (T.K.) 3Department of Structural Mechanics, VSB-Technical University of Ostrava, 70800 Ostrava, Czech Republic; [email protected] *Correspondence: [email protected] Abstract: Building constructions and their elements must meet requirements related to stability and strength. These are the conditions that determine the safety of the structure during both construction and operation. Safety assessment is based on diagnostic tests, aimed at checking the quality of the erected objects or locating damage to structural elements that arise during operation. This work focuses on experimental SISO modal analysis of ceramic masonry elements. An experiment was carried out on twenty samples of solid brick (good, and intentionally damaged). From this, it was possible to determine the variability of the obtained measurement results of the vibration characteristics of the masonry element, and, thus, to assess the value of the method used in the given research problem. The aim of this study was to test the effectiveness of assessing the degradation of the tested brick elements based on stabilization diagrams. The research confirmed the usefulness of experimental modal analysis in identifying damage to masonry elements, and it has been implemented in selected brickyards in Poland. Keywords: masonry elements; vibrations; diagnostics; modal analysis 1. Introduction The dynamic properties of building structures have a direct impact on the vibration level of the system, noise emissions, fatigue strength, and structural stability. In most cases, the analysis of dynamic properties encountered in practice is carried out on the basis of the analysis of the behavior of the structural model, because the study of real objects is not always possible. In most applications, simple identification methods are used, where changes in m, k, and c values (mass, stiffness, and damping) or changes in the parameters of amplitude–frequency characteristics (spectrum of the vibration process) are determined. For complex, often non-linear systems, complex modal analysis (theoretical, experimental, or operational) is used. The modal model, which is an ordered set of natural frequencies, the corresponding damping coefficients, and the modes of natural vibrations, allows predicting the reaction of an object to any disturbance, in both the time and frequency domains. New tools in the field of non-invasive tests concern the possibility of using vibration diagnostics methods and modal analysis methods, as well as modern vibration acquisition and processing, to assess the quality of elements and entire fragments of building structures. In practical applications, they allow for a better understanding of the behavior of individual tested elements and building materials, as well as complex structures, with optimization in the process of their design and assessment of hazardous conditions. Materials 2022,15, 1452. https://doi.org/10.3390/ma15041452 https://www.mdpi.com/journal/materials Materials 2022,15, 1452 2 of 14 Modal analysis is used in diagnostics, modification, and monitoring of structures, as well as in the validation and control of analytical and numerical models; it is widely used in mechanical engineering, in the aviation industry, in electronics and electrical engineering, rail transport, and even in agriculture [ 1 – 3 ]. The analysis does not directly observe the effects of damage or wear, but only their signs, in the form of values of measured quantities such as stabilization diagrams or accompanying vibration estimators. Only an appropriate analysis (interpretation) of the measured vibration signals enables the recognition of the technical condition of a machine or structure elements, detection (localization) and determination of damage severity, and determination of their causes and measures. The quality of the analysis depends on the reliability of the adopted structural model in the FEM environment, in the case of theoretical modal analysis or the physical model of the real object, or its part in the case of experimental modal analysis. Modal analysis can also be carried out during normal operation on a real object, in which case it is referred to as operational [4,5]. Experimental modal analysis usually consists in forcing the movement of the examined system (object) and measuring the forcing and response. The analysis procedure can be carried out by various methods When an object is excited by a modal hammer at subsequent points and the vibration sensor (transducer) is fixed at a fixed point, or when the object is excited by a modal hammer at one point and the vibration sensor (transducer) changes position, we use the SISO (single input single output) method. In cases where there is more than one vibration sensor, this is called SIMO (single input multiple outputs) [6,7]. The purpose of this work was to conduct an experimental modal analysis using the SISO method and to confirm its usefulness in identifying damage to masonry elements, based on a comparison of the FRF function and stabilization diagrams in a damaged and undamaged object. The frequency response function (transition function) is a ratio of output signal spectrum to the input signal, as a function of frequency, it is a composite function and can be represented by the formula [6–10]: FRF(ω)=X(ω) F(ω), (1) where X(ω)-response spectrum of the system x(t),F(ω)-input signal spectrum F(t). On this basis, it is possible to determine the natural frequency of the system. Whereas the coherence function expressed by the formula [10–12]: γ2 xF(f)=|GxF(f)|2 Gxx(f)GFF(f)(2) where GxF(f) -reciprocal power spectral density between input (reference) signal F(t) and exit signal (answers) x(t) , GFF(f) -the spectral density of the input signal power F(t) , Gxx(f) - the spectral density of the response signal power x(t) , describes the similarity of two signals as a function of frequency. If signals x(t) and F(t) come from the same source, the coherence function always assumes a value of 1. Modal analysis has been used for many years in technical mechanics; in construction it is less widespread. In science publications by many authors [ 11 , 12 ], it has been proven that it is possible to use this methodology in research evaluation of mechanical properties in various structures. Later, authors such as [ 13 , 14 ] adapted this research methodology to civil engineering. Many years of tests conducted on real building structures made it possible to create a new methodology dedicated to the use in research of different civil engineering elements, including masonry elements. Materials 2022,15, 1452 3 of 14 2. Materials and Methods The subject of this study are ceramic masonry elements in the form of solid brick and checker brick (Figure 1). Ten intact and 10 damaged samples of each type of brick were tested. Damage was caused (forced) by a testing machine, by applying an increasing compressive force to the sample axially in the direction of the Z axis, until the first signs of damage appeared, as seen in the figures. Materials 2022, 15, x FOR PEER REVIEW 3 of 14 possible to create a new methodology dedicated to the use in research of different civil engineering elements, including masonry elements. 2. Materials and Methods The subject of this study are ceramic masonry elements in the form of solid brick and checker brick (Figure 1). Ten intact and 10 damaged samples of each type of brick were tested. Damage was caused (forced) by a testing machine, by applying an increasing compressive force to the sample axially in the direction of the Z axis, until the first signs of damage appeared, as seen in the figures. The research was performed on building material in the form of a solid ceramic brick of type L (veneer) B (without holes), as shown in Figure 1. Ceramic brick is made in class 20, which corresponds to a compressive strength of 20 MPa. The ceramic brick was 25 cm long, 12 cm wide, and 6.5 cm high. The ceramic brick had even sides, uniform color, and no cracks and nicks. Figure 1. View of solid brick samples subjected to measurements. The modal test was carried out by forcing the samples to vibrate with a modal hammer blow. The SISO method was used, in which the strokes were made at one point and the location of the response changes [13]. The sample was suspended on an unstretched fishing line, which allowed all bonds to be released, and then the vibrations were forced from above in the direction of the Z axis; because from a practical point of view, the information regarding the transition of the vibration signal in the direction consistent with the direction of action of the compressive forces of the wall made of the tested element is important. The signal was received using a piezoelectric sensor glued onto a given wall of the sample. Response measurement points were determined and measured 10 times each, which allowed obtaining an average unloaded value of frequency characteristics [14,15]. SIEMENS LMS Test.Xpress measuring equipment (Figure 2) was used to measure the time histories of system excitation and response. This software makes it easy to carry out modal analysis of brick elements, as well as any other building structures. As a result of the tests, time courses of excitation force (modal hammer) and time courses of response (piezoelectric sensor) were obtained, as well as their visualizations. During the vibration tests, the possibility of acquiring new cognitive values that could be useful for assessing the destruction of the tested masonry elements was analyzed. Such information, apart from the time course of extortion, may be derived from the numerical value of the surface area of the obtained frequency functions of the signal passing through the tested element [16]. 2.1. Experimental Modal Analysis The modal analysis method is used for examining dynamic properties; tracking parameters changes in a wall element model, resulting in wear, damage, or failure. A modal Figure 1. View of solid brick samples subjected to measurements. The research was performed on building material in the form of a solid ceramic brick of type L (veneer) B (without holes), as shown in Figure 1. Ceramic brick is made in class 20, which corresponds to a compressive strength of 20 MPa. The ceramic brick was 25 cm long, 12 cm wide, and 6.5 cm high. The ceramic brick had even sides, uniform color, and no cracks and nicks. The modal test was carried out by forcing the samples to vibrate with a modal hammer blow. The SISO method was used, in which the strokes were made at one point and the location of the response changes [ 13 ]. The sample was suspended on an unstretched fishing line, which allowed all bonds to be released, and then the vibrations were forced from above in the direction of the Z axis; because from a practical point of view, the information regarding the transition of the vibration signal in the direction consistent with the direction of action of the compressive forces of the wall made of the tested element is important. The signal was received using a piezoelectric sensor glued onto a given wall of the sample. Response measurement points were determined and measured 10 times each, which allowed obtaining an average unloaded value of frequency characteristics [14,15]. SIEMENS LMS Test.Xpress measuring equipment (Figure 2) was used to measure the time histories of system excitation and response. This software makes it easy to carry out modal analysis of brick elements, as well as any other building structures. As a result of the tests, time courses of excitation force (modal hammer) and time courses of response (piezoelectric sensor) were obtained, as well as their visualizations. During the vibration tests, the possibility of acquiring new cognitive values that could be useful for assessing the destruction of the tested masonry elements was analyzed. Such information, apart from the time course of extortion, may be derived from the numerical value of the surface area of the obtained frequency functions of the signal passing through the tested element [16]. Materials 2022,15, 1452 4 of 14 Materials 2022, 15, x FOR PEER REVIEW 4 of 14 model is created in the form of a set of natural frequencies, vibration modes, and damping coefficients for an object without damage as a pattern. During operation, the modal model is identified, and compared with the undamaged object. When correlation occurs, it shows the object is fit. In the absence of correlation, the object is in a state of unfitness, caused, for example, by aging or damage [16,17]. Figure 2. SIEMENS LMS Test.Xpress measuring equipment. The sets of eigenfrequencies, the damping, and the modes of free vibrations determined in the eigenvalues problem allow structural behavior simulation under excitation, control selection, structure modification, and other factors. The analysis of eigenfrequencies and eigenvectors is obtained from the motion equation (after omitting terms containing the damping matrix and external loads vector). The natural vibration motion equation has the following form:   󰇘 +  = 0 (3) For a system with one degree of freedom, the solution is:  (  ) =   sin (  +  ) (4) where is the vector of the natural vibration amplitudes. Substituting the above equation and the second derivative into the equation of motion, we achieve: ( −    +  )   sin (  −  ) = 0 (5) The above equation must be fulfilled for any moment t; then, the system of algebraic equations is obtained: q  Figure 2. SIEMENS LMS Test.Xpress measuring equipment. 2.1. Experimental Modal Analysis The modal analysis method is used for examining dynamic properties; tracking parameters changes in a wall element model, resulting in wear, damage, or failure. A modal model is created in the form of a set of natural frequencies, vibration modes, and damping coefficients for an object without damage as a pattern. During operation, the modal model is identified, and compared with the undamaged object. When correlation occurs, it shows the object is fit. In the absence of correlation, the object is in a state of unfitness, caused, for example, by aging or damage [16,17]. The sets of eigenfrequencies, the damping, and the modes of free vibrations determined in the eigenvalues problem allow structural behavior simulation under excitation, control selection, structure modification, and other factors. The analysis of eigenfrequencies and eigenvectors is obtained from the motion equation (after omitting terms containing the damping matrix and external loads vector). The natural vibration motion equation has the following form: M.. q+Kq =0 (3) For a system with one degree of freedom, the solution is: q(t)=→ qsin(ωt+ϕ)(4) where → qis the vector of the natural vibration amplitudes. Substituting the above equation and the second derivative into the equation of motion, we achieve: −ω2M+K→ qsin(ωt−ϕ)=0 (5) The above equation must be fulfilled for any moment t; then, the system of algebraic equations is obtained: K−ω2M→ q=0 k11 −ω2m11q1+k12 −ω2m12q2+. . . +k1n−ω2m1nqn=0 k21 −ω2m21q1+k22 −ω2m22q2+. . . +k2n−ω2m2nqn=0 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− kn1−ω2mn1q1+kn2−ω2mn2q2+. . . +knn −ω2mnnqn=0 (6) Materials 2022,15, 1452 5 of 14 The result is a linear homogeneous algebraic equations system that has a non-zero solution, only when detK−ω2B=0 (7) After transformations, we obtain an nth degree polynomial with respect to ω2 . Multiple roots can occur among the roots, and the vector made up of a frequency set arranged in an increasing value order is called the frequency vector, and the first frequency is called the fundamental frequency [6]. ω=[ω1,ω2, . . . , ωn](8) Experimental modal analysis was used for identifying the structure modal parameters. The identification experiment consisted of object vibration forcing with the simultaneous measurement of the exciting force and response, in the form of a vibration acceleration spectrum. The modal model was obtained from the stabilization diagram. The identification experiment in EMA is shown in Figure 3. Materials 2022, 15, x FOR PEER REVIEW 5 of 14 (  −    )   = 0 ( − )+( − )+ . . . +( − )= 0 ( − )+( − )+ . . . +( − )= 0 −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−− (    −      )   + (    −      )   + . . . + (   −     )   = 0 6) The result is a linear homogeneous algebraic equations system that has a non-zero solution, only when det (  −    ) = 0 (7) After transformations, we obtain an nth degree polynomial with respect to . Multiple roots can occur among the roots, and the vector made up of a frequency set arranged in an increasing value order is called the frequency vector, and the first frequency is called the fundamental frequency [6].  = [   ,   … . ,   ] (8) Experimental modal analysis was used for identifying the structure modal parameters. The identification experiment consisted of object vibration forcing with the simultaneous measurement of the exciting force and response, in the form of a vibration acceleration spectrum. The modal model was obtained from the stabilization diagram. The identification experiment in EMA is shown in Figure 3. Figure 3. The essence of research in experimental and operational modal analysis. The measurement results were processed in the software system (SIEMENS LMS), obtaining the vibration spectrum of the driving force at the system input, the spectrum of the vibration acceleration amplitude at the system output, and stabilization diagram; from which we were able to estimate the parameters of the modal model [8,6]. A TSD (traditional stabilization diagram) is a graph where the frequencies are plotted as the X-axis and the model orders as the Y-axis. It shows the poles of a system at different model orders. Physical poles occur at the same frequency at increasing model orders, forming a vertical column of poles, whereas the spurious numerical poles will not stabilize Figure 3. The essence of research in experimental and operational modal analysis. The measurement results were processed in the software system (SIEMENS LMS), obtaining the vibration spectrum of the driving force at the system input, the spectrum of the vibration acceleration amplitude at the system output, and stabilization diagram; from which we were able to estimate the parameters of the modal model [6,8]. A TSD (traditional stabilization diagram) is a graph where the frequencies are plotted as the X-axis and the model orders as the Y-axis. It shows the poles of a system at different model orders. Physical poles occur at the same frequency at increasing model orders, forming a vertical column of poles, whereas the spurious numerical poles will not stabilize during this process and can be disregarded more easily. The modal parameters are computed from the physical modes in the same order. It should be noted that the most crucial step of using a TSD to identify parameter identification is selecting a stable vertical column of poles (Figure 4). 2.2. Measurement Systems The SIEMENS LMS SCADAS Recorder system is one of the most advanced measurement systems using the modal analysis methodology in research of degradation. It is a measurement system for data acquisition, analysis, and reporting. It includes procedures dedicated to structural and acoustic testing, environmental testing, and quality testing. Test.Lab is used to provide data collected on real objects and integrate them into the simulation process. These data are described as time waveforms, stabilization diagrams, cross power waveforms, etc. Materials 2022,15, 1452 6 of 14 The condition of masonry elements should be tested with a simple and effective method, using the minimum number of measurements. This software allows easily conducting, according to the developed degradation state analysis algorithm, modal analysis of masonry elements and any other building structures. Correct measurement depends on obtaining the level of the exciting force that was previously determined and on an appropriate level of response signal. Repeatability tests of waveforms concerning measurements of changes in material destruction state are the biggest advantages of the SIEMENS LMS measurement system. Materials 2022, 15, x FOR PEER REVIEW 6 of 14 during this process and can be disregarded more easily. The modal parameters are computed from the physical modes in the same order. It should be noted that the most crucial step of using a TSD to identify parameter identification is selecting a stable vertical column of poles (Figure 4). Figure 4. Stabilization diagram. Notations: order = order of the pole, o = unstable pole, f = pole has a constant frequency. v = pole has a constant frequency and modal vector; s—stable pole. 2.2. Measurement Systems The SIEMENS LMS SCADAS Recorder system is one of the most advanced measurement systems using the modal analysis methodology in research of degradation. It is a measurement system for data acquisition, analysis, and reporting. It includes procedures dedicated to structural and acoustic testing, environmental testing, and quality testing. Test.Lab is used to provide data collected on real objects and integrate them into the simulation process. These data are described as time waveforms, stabilization diagrams, cross power waveforms, etc. The condition of masonry elements should be tested with a simple and effective method, using the minimum number of measurements. This software allows easily conducting, according to the developed degradation state analysis algorithm, modal analysis of masonry elements and any other building structures. Correct measurement depends on obtaining the level of the exciting force that was previously determined and on an appropriate level of response signal. Repeatability tests of waveforms concerning measurements of changes in material destruction state are the biggest advantages of the SIEMENS LMS measurement system. 3. Results and Discussion 3.1. Modal Analysis Results of Solid Brick Samples The object of this research was a building material in the form of a solid ceramic brick of type L (veneer) B (without holes), shown in Figure 5. The ceramic brick was made to class 20, which corresponds to a compressive strength of 20 MPa. The ceramic brick was 25 cm long, 12 cm wide, and 6.5 cm high. The ceramic brick had even sides, uniform color, and no cracks and nicks. 3.2. Research Methodology The modal study was performed on a full ceramic brick using experimental modal analysis. In this method, using a modal hammer (PCB 086C03), structural vibrations of the test object were induced, registering them with a uniaxial piezoelectric vibration Figure 4. Stabilization diagram. Notations: order = order of the pole, o = unstable pole, f = pole has a constant frequency. v = pole has a constant frequency and modal vector; s—stable pole. 3. Results and Discussion 3.1. Modal Analysis Results of Solid Brick Samples The object of this research was a building material in the form of a solid ceramic brick of type L (veneer) B (without holes), shown in Figure 5. The ceramic brick was made to class 20, which corresponds to a compressive strength of 20 MPa. The ceramic brick was 25 cm long, 12 cm wide, and 6.5 cm high. The ceramic brick had even sides, uniform color, and no cracks and nicks. Materials 2022, 15, x FOR PEER REVIEW 7 of 14 sensor (PCB 333B50). The measurement points were placed on the research object in accordance with the diagram presented below—Figure 5. Figure 5. Distribution of measurement points on the research object. Excitation of the test object with vibrations was carried out at point C1. Two waveforms were recorded in the experiment: one from the modal hammer, and the other from the vibration sensor attached to the test object. As a result of the recorded time courses, spectral functions of the FRF transition were obtained (Figure 6). At each of the measurement points, the obtained FRF waveform was the result of averaging 10 successive blows with a modal hammer. On this basis, a stabilization diagram was constructed, from which individual modal parameters were estimated in the form of natural frequency, modal damping coefficients, and vibration modes. Based on these parameters, a modal model of an undamaged ceramic brick was created; thus, completing the first stage of modal research of the object. The next, second, stage of modal tests consisted in subjecting a full ceramic brick to a compression strength test on an Instron testing machine. A load of 30 MPa was applied on the testing machine. This value is 10 MPa higher than the maximum compressive strength of a full brick. The endurance test was carried out until the first symptoms of damage to the test object were noticed in the form of cracks, while not leading to the complete destruction of the brick. Figure 7 shows the cracks of the solid brick obtained after the strength test. The full ceramic brick with the fracture was then subjected to a modal test, to observe changes between the individual modal models. Figure 5. Distribution of measurement points on the research object. 3.2. Research Methodology The modal study was performed on a full ceramic brick using experimental modal analysis. In this method, using a modal hammer (PCB 086C03), structural vibrations of the Materials 2022,15, 1452 7 of 14 test object were induced, registering them with a uniaxial piezoelectric vibration sensor (PCB 333B50). The measurement points were placed on the research object in accordance with the diagram presented below—Figure 5. Excitation of the test object with vibrations was carried out at point C1. Two waveforms were recorded in the experiment: one from the modal hammer, and the other from the vibration sensor attached to the test object. As a result of the recorded time courses, spectral functions of the FRF transition were obtained (Figure 6). At each of the measurement points, the obtained FRF waveform was the result of averaging 10 successive blows with a modal hammer. On this basis, a stabilization diagram was constructed, from which individual modal parameters were estimated in the form of natural frequency, modal damping coefficients, and vibration modes. Based on these parameters, a modal model of an undamaged ceramic brick was created; thus, completing the first stage of modal research of the object. The next, second, stage of modal tests consisted in subjecting a full ceramic brick to a compression strength test on an Instron testing machine. A load of 30 MPa was applied on the testing machine. This value is 10 MPa higher than the maximum compressive strength of a full brick. The endurance test was carried out until the first symptoms of damage to the test object were noticed in the form of cracks, while not leading to the complete destruction of the brick. Figure 7shows the cracks of the solid brick obtained after the strength test. The full ceramic brick with the fracture was then subjected to a modal test, to observe changes between the individual modal models. The crack in the solid ceramic brick was between measuring points C1 and C2, and C7 and C8. In the modal tests, a frequency range from 0.7 Hz to 6375 Hz was adopted, due to the theoretical first natural frequency for a full ceramic brick occurring at approx. 2927.63 Hz (and 2927.68 Hz based on the tables). Materials 2022, 15, x FOR PEER REVIEW 7 of 14 sensor (PCB 333B50). The measurement points were placed on the research object in accordance with the diagram presented below—Figure 5. Figure 5. Distribution of measurement points on the research object. Excitation of the test object with vibrations was carried out at point C1. Two waveforms were recorded in the experiment: one from the modal hammer, and the other from the vibration sensor attached to the test object. As a result of the recorded time courses, spectral functions of the FRF transition were obtained (Figure 6). At each of the measurement points, the obtained FRF waveform was the result of averaging 10 successive blows with a modal hammer. On this basis, a stabilization diagram was constructed, from which individual modal parameters were estimated in the form of natural frequency, modal damping coefficients, and vibration modes. Based on these parameters, a modal model of an undamaged ceramic brick was created; thus, completing the first stage of modal research of the object. The next, second, stage of modal tests consisted in subjecting a full ceramic brick to a compression strength test on an Instron testing machine. A load of 30 MPa was applied on the testing machine. This value is 10 MPa higher than the maximum compressive strength of a full brick. The endurance test was carried out until the first symptoms of damage to the test object were noticed in the form of cracks, while not leading to the complete destruction of the brick. Figure 7 shows the cracks of the solid brick obtained after the strength test. The full ceramic brick with the fracture was then subjected to a modal test, to observe changes between the individual modal models. Figure 6. Spectral function of the FRF transition registered at point C1. Materials 2022,15, 1452 8 of 14 Materials 2022, 15, x FOR PEER REVIEW 8 of 14 Figure 6. Spectral function of the FRF transition registered at point C1. Figure 7. Clear fracture of the full ceramic brick after the strength test. The crack in the solid ceramic brick was between measuring points C1 and C2, and C7 and C8. In the modal tests, a frequency range from 0.7 Hz to 6375 Hz was adopted, due to the theoretical first natural frequency for a full ceramic brick occurring at approx. 2927.63 Hz (and 2927.68 Hz based on the tables). 4. Results of the Modal Study 4.1. Undamaged Solid Ceramic Brick Measurement results for an undamaged solid brick were obtained from a total of eight measuring points, four on each side of the brick. Figure 8 shows the average FRF plot from the eight measurement points, on which the calculated theoretical first frequency of natural vibrations was based. There was only one peak (2875.97 Hz) in the vicinity of this value, which could indicate convergence of these frequencies. Based on this diagram, it can also be observed that at this frequency there is a clear change of the vibration phase, which also indicates the presence of structural vibrations of the test object at this place. Figure 8. The theoretical first natural frequency of brick vibrations in the averaged FRF plot. Based on the measured characteristics of the FRF, a stabilization diagram was created (Figure 9) for an undamaged solid ceramic brick. The size of the modal model was limited to 128, assuming the multivariant option. Figure 11 shows a stabilization diagram with numerous stable poles that may constitute potential structural vibrations of the research object. Figure 7. Clear fracture of the full ceramic brick after the strength test. 4. Results of the Modal Study 4.1. Undamaged Solid Ceramic Brick Measurement results for an undamaged solid brick were obtained from a total of eight measuring points, four on each side of the brick. Figure 8shows the average FRF plot from the eight measurement points, on which the calculated theoretical first frequency of natural vibrations was based. There was only one peak (2875.97 Hz) in the vicinity of this value, which could indicate convergence of these frequencies. Based on this diagram, it can also be observed that at this frequency there is a clear change of the vibration phase, which also indicates the presence of structural vibrations of the test object at this place. Materials 2022, 15, x FOR PEER REVIEW 8 of 14 Figure 6. Spectral function of the FRF transition registered at point C1. Figure 7. Clear fracture of the full ceramic brick after the strength test. The crack in the solid ceramic brick was between measuring points C1 and C2, and C7 and C8. In the modal tests, a frequency range from 0.7 Hz to 6375 Hz was adopted, due to the theoretical first natural frequency for a full ceramic brick occurring at approx. 2927.63 Hz (and 2927.68 Hz based on the tables). 4. Results of the Modal Study 4.1. Undamaged Solid Ceramic Brick Measurement results for an undamaged solid brick were obtained from a total of eight measuring points, four on each side of the brick. Figure 8 shows the average FRF plot from the eight measurement points, on which the calculated theoretical first frequency of natural vibrations was based. There was only one peak (2875.97 Hz) in the vicinity of this value, which could indicate convergence of these frequencies. Based on this diagram, it can also be observed that at this frequency there is a clear change of the vibration phase, which also indicates the presence of structural vibrations of the test object at this place. Figure 8. The theoretical first natural frequency of brick vibrations in the averaged FRF plot. Based on the measured characteristics of the FRF, a stabilization diagram was created (Figure 9) for an undamaged solid ceramic brick. The size of the modal model was limited to 128, assuming the multivariant option. Figure 11 shows a stabilization diagram with numerous stable poles that may constitute potential structural vibrations of the research object. Figure 8. The theoretical first natural frequency of brick vibrations in the averaged FRF plot. Based on the measured characteristics of the FRF, a stabilization diagram was created (Figure 9) for an undamaged solid ceramic brick. The size of the modal model was limited to 128, assuming the multivariant option. Figure 10 shows a stabilization diagram with numerous stable poles that may constitute potential structural vibrations of the research object. To confirm the selected stable poles, which presumably may be structural vibrations of a solid brick, validation of the selected poles and the corresponding forms of free vibration should be performed. The validation was carried out using the AutoMAC function, the results of which, in relation to the analyzed object, are shown in Figure 11. On this basis, five characteristic modes of free vibrations of the undamaged full ceramic brick were selected, and are summarized in Table 1. List of natural frequencies and damping coefficients for undamaged solid ceramic brick are shown in Table 2. Materials 2022,15, 1452 9 of 14 Materials 2022, 15, x FOR PEER REVIEW 9 of 14 Figure 9. Stabilization diagram made with the use of the SUM indicator with eight measurement points for an undamaged full ceramic brick. To confirm the selected stable poles, which presumably may be structural vibrations of a solid brick, validation of the selected poles and the corresponding forms of free vibration should be performed. The validation was carried out using the AutoMAC function, the results of which, in relation to the analyzed object, are shown in Figure 10. On this basis, five characteristic modes of free vibrations of the undamaged full ceramic brick were selected, and are summarized in Table 1. List of natural frequencies and damping coefficients for undamaged solid ceramic brick are shown in Table 2. Figure 10. Validation of selected stable poles and the corresponding modes of free vibrations using the AutoMAC function. Figure 9. Stabilization diagram made with the use of the SUM indicator with eight measurement points for an undamaged full ceramic brick. Materials 2022, 15, x FOR PEER REVIEW 10 of 14 Table 1. The result of the validation (AutoMAC) in tabular form for undamaged solid ceramic brick. Undamaged Full Brick MODE 1 MODE 2 MODE 3 MODE 4 MODE 5 2812.16 2863.48 3292.11 4879.58 5572.45 MODE 1 2812.16 100 1.49 6.11 0.03 7.77 MODE 2 2863.48 1.49 100 2.92 7.25 1.91 MODE 3 3292.11 6.11 2.92 100 25.97 0.20 MODE 4 4879.58 0.03 7.25 25.96 100 24.29 MODE 5 5572.45 7.77 1.91 0.20 24.28 100 Table 2. List of natural frequencies and damping coefficients for undamaged solid ceramic brick. Undamaged Solid Brick Natural Vibrations Frequency Damping (Hz) (%) Mode 1 2812.162 0.44 Mode 2 2863.480 0.82 Mode 3 3292.101 0.13 Mode 4 4879.585 0.14 Mode 5 5572.447 0.34 Each of the determined frequencies of natural vibrations has an appropriate form of these vibrations. The individual modes of the free vibrations for the undamaged full ceramic brick in their maximum deflection from the equilibrium position are presented in the figure below. (2812.16Hz) (2863.48Hz) (3292,11Hz) (4879.58Hz) (5572.45Hz) Figure 11. Natural frequency values of the undamaged solid ceramic brick. 4.2. Damaged Full Ceramic Brick Measurement results for a damaged full brick were obtained from a total of eight measuring points, four on each side of the brick. Figure 14 shows the average FRF plot from the eight measurement points, on which the calculated theoretical first frequency of natural vibrations was based. There was only one peak (3053.40 Hz) in the vicinity of this value, which would indicate a convergence of these frequencies. Based on this diagram, it can also be observed that at this frequency there is a clear change of the vibration phase, which also indicates the presence of structural vibrations of the test object in this place. Theoretical first natural frequency of brick vibrations are verry good shown in FRF function diagram—Figure 12. Figure 10. Natural frequency values of the undamaged solid ceramic brick. Materials 2022, 15, x FOR PEER REVIEW 9 of 14 Figure 9. Stabilization diagram made with the use of the SUM indicator with eight measurement points for an undamaged full ceramic brick. To confirm the selected stable poles, which presumably may be structural vibrations of a solid brick, validation of the selected poles and the corresponding forms of free vibration should be performed. The validation was carried out using the AutoMAC function, the results of which, in relation to the analyzed object, are shown in Figure 10. On this basis, five characteristic modes of free vibrations of the undamaged full ceramic brick were selected, and are summarized in Table 1. List of natural frequencies and damping coefficients for undamaged solid ceramic brick are shown in Table 2. Figure 10. Validation of selected stable poles and the corresponding modes of free vibrations using the AutoMAC function. Figure 11. Validation of selected stable poles and the corresponding modes of free vibrations using the AutoMAC function.