Full text
Citation: Chaves, E.; Aguilar, J.; Barontini, A.; Mendes, N.; Compán, V. Digital Tools for the Preventive Conservation of Built Heritage: The Church of Santa Ana in Seville. Heritage 2024,7, 3470–3494. https:// doi.org/10.3390/heritage7070164 Academic Editor: Marco Di Ludovico Received: 3 June 2024 Revised: 28 June 2024 Accepted: 29 June 2024 Published: 30 June 2024 Copyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). heritage Article Digital Tools for the Preventive Conservation of Built Heritage: The Church of Santa Ana in Seville Estefanía Chaves 1,*, Jaime Aguilar 2, Alberto Barontini 1, Nuno Mendes 1and Víctor Compán2 1ISISE, ARISE, Department of Civil Engineering, University of Minho, 4800-058 Guimarães, Portugal 2Department of Building Structures and Geotechnical Engineering, University of Seville, 41012 Seville, Spain *Correspondence: [email protected] Abstract: Historic Building Information Modelling (HBIM) plays a pivotal role in heritage conservation endeavours, offering a robust framework for digitally documenting existing structures and supporting conservation practices. However, HBIM’s efficacy hinges upon the implementation of case-specific approaches to address the requirements and resources of each individual asset and context. This paper defines a flexible and generalisable workflow that encompasses various aspects (i.e., documentation, surveying, vulnerability assessment) to support risk-informed decision making in heritage management tailored to the peculiar conservation needs of the structure. This methodology includes an initial investigation covering historical data collection, metric and condition surveys and non-destructive testing. The second stage includes Finite Element Method (FEM) modelling and structural analysis. All data generated and processed are managed in a multi-purpose HBIM model. The methodology is tested on a relevant case study, namely, the church of Santa Ana in Seville, chosen for its historical significance, intricacy and susceptibility to seismic action. The defined level of detail of the HBIM model is sufficient to inform the structural analysis, being balanced by a more accurate representation of the alterations, through linked orthophotos and a comprehensive list of alphanumerical parameters. This ensures an adequate level of information, optimising the trade-off between model complexity, investigation time requirements, computational burden and reliability in the decision-making process. Field testing and FEM analysis provide valuable insight into the main sources of vulnerability in the building, including the connection between the tower and nave and the slenderness of the columns. Keywords: digital twin; seismic assessment; photogrammetry; virtual model; dynamic identification; model calibration 1. Introduction Heritage buildings are a vital legacy for future generations; however, these buildings are constantly threatened by natural and human-induced hazards, deterioration and ageing. Though the conservation and reuse of these buildings have gained momentum, the challenges are undeniable. A long-lasting lack of maintenance complicated by growing aggressiveness of environmental and operational conditions (e.g., climate change effects, increase in service load, etc.), recent budget cuts, financial crises and the need for sustainable use of resources call for cost-effective practices in built heritage management [ 1 , 2 ]. This shift in perspective from remedial and emergency interventions to proactive and preventive conservation is currently promoted by national and international policies and institutions such as the International Council for Monuments and Sites (ICOMOS) [3]. Within this new vision, the conservation of historic buildings requires a thorough understanding of the building and its ambient specific needs, character-defining elements, structural systems, material properties, boundary conditions, vulnerabilities to the expected sources of hazards, current state and its anticipated evolution. Moreover, any activity carried out must comply with critical conservation principles, such as minimum intervention, Heritage 2024,7, 3470–3494. https://doi.org/10.3390/heritage7070164 https://www.mdpi.com/journal/heritage
Heritage 2024,73471 compatibility, durability and reversibility. Thus, accurate inspection and diagnosis are necessary tasks, repeated over time, and experimental tests become indispensable, as they are the key for acquiring crucial input data for accurate structural assessments and monitoring. These are fundamental tools for the continuous analysis of the behaviour of the structure or the evaluation of interventions [4]. Developing and implementing cost-effective conservation frameworks capable of addressing all the above-mentioned aspects is paramount. To this end, a holistic approach that integrates risk assessment and condition-monitoring strategies emerges as a promising solution to ensure an efficient and timely conservation of built heritage [ 2 , 5 ]. This approach involves systematically identifying and analysing potential risks to the integrity of the historical structure, establishing connections between causal factors, visible damage and anticipated consequences to forecast potential losses under expected hazard scenarios. Simultaneously, it incorporates continuous or periodic monitoring of the asset’s condition to detect, in almost real-time, any occurrence or evolution of the damage [ 6 ]. This combination targets and prioritises the conservation efforts supporting proactive maintenance activities and optimised allocation of resources. The effective integration of risk assessment with condition-monitoring strategies depends on the development of a robust model capable of acting as a dynamic counterpart to the real structure that evolves in parallel to it, reflecting its variations over time and allowing a forward-looking view of the evolution of its performance [7]. This digital twin model concept can be grounded on the Building Information Modelling (BIM) methodology. After its promising applications for new buildings, this approach has gained an important role in the field of the preservation of heritage buildings, as the so-called Historical BIM (HBIM) [ 8 ]. By employing HBIM principles, the digital twins of historic buildings not only capture their current state but also allow for simulations, predictive analysis and informed decisions on conservation, restoration and adaptation [ 9 – 11 ]. This holistic approach facilitates a deeper understanding of historic structures, helps preserve cultural heritage and guides management practices towards a more sustainable and efficient path. Within HBIM practice, the implementation of an appropriate workflow and methodology strongly depends on the identification of the model goals and anticipated uses. In particular, this drives the definition of the Level of Information Need [ 12 ]. The Level of Information Need is not only about the graphic fidelity of the building elements, which encompasses factors such as geometry, scale and orientation [13]. It also includes the nongraphical embedded data and the linked information (e.g., reports or images) associated with these elements, such as material properties, ongoing deterioration mechanisms, test results, historical data, etc. [ 8 ]. A proper definition of this level aims at a cost-effective balance between highly detailed geometry and linked alphanumerical information and additional documentation [ 14 – 16 ]. For instance, models intended to inform the design of interventions [ 15 , 17 ] may require more geometrical accuracy and resolution than those for supporting inspection and management tasks. Agents’ involvement is equally critical throughout the process. Indeed, the characteristics of the model must be agreed upon by all the parties, including those involved in data collection and model design as well as the end users. Simplification of the process is essential, especially as stakeholders may have little or no experience with BIM methodologies. To this end, delivering the model in an open access format eliminates the need for costly licences and ensures wide accessibility [ 18 ]. The methodology for implementing new information and updating the model should be intuitive and simple. This facilitates the effective contribution of stakeholders, regardless of their level of BIM expertise. Standardised forms linked to the initial model can streamline data input and updates, simplifying the overall process. Developing an effective methodology for HBIM implementation is crucial to successfully manage and preserve historic structures. By defining clear objectives, involving stakeholders and applying easy-to- understand processes, the full potential of BIM in historic preservation can be realised [ 19 ]. Although HBIM practices are increasingly used in heritage management [ 11 , 20 – 22 ], these often address specific tasks of the conservation, and an all-encompassing streamlined
Heritage 2024,73472 workflow that is replicable, standardised and user-friendly is still missing. Therefore, it is crucial to continue working on the adaptation of BIM to historic buildings and to make its applications available to experts. The present paper aims to address this issue by testing and validating a streamlined workflow on a significative and complex historical building, namely, the church of Santa Ana in Seville, Spain. This comprehensive workflow aims to include several tasks of built heritage conservation, including archive searches, geometric and damage surveys, material characterisation and vulnerability analysis using numerical simulation, providing a simple strategy to manage data collection, retrieval and sharing in a HBIM environment. One of the main objectives of this application is to optimise the way information is collected and shown in the model, taking into account the specific BIM model goals and needs, to provide a solution that is able to maximise quality and accuracy based on the available resources, ensuring that under realistic operational, temporal and budgetary constraints, a sufficient level of knowledge can be generated to inform condition assessment and numerical structural analyses. Thus, this methodology is presented as an accessible tool regardless of the project’s size or the stakeholders’ experience and capacity. At the same time, it is flexible enough to integrate more advanced strategies for data collection and processing when the allocated resources allow it. The investigated building presents complex architectural and constructive features and is representative of many of the religious buildings in southern Spain. Furthermore, it has suffered damage across its life due to different catastrophes, mainly earthquakes. The generated model constitutes the core of the envisaged digital twin of the heritage building, allowing a systematisation of the results of the ongoing research activities and encompassing historical data and documentary search, inspection, testing, diagnosis and structural assessment through numerical simulations. The paper is organised as follows. Section 2explains in detail the methodology employed here. Section 3describes the case study, including the definition of the building, the results obtained from the historical survey and the description of the seismic area where it is located. Section 4includes the inspection, geometry survey, damage survey and in situ tests performed to characterise the building. Section 5describes the HBIM model and the strategy to integrate the collected information. Section 6contains the information about the structural model based on the HBIM model, the calibration and the results of the seismic analysis. Finally, Section 7describes the conclusions of the work and future scopes. 2. Methodology Proposal for HBIM Implementation The methodology presented focuses on the definition of a model for the preventive conservation of heritage buildings. This model integrates information derived from historical studies and documentary search, geometrical survey based on photogrammetry or similar techniques, inspection and condition surveys, material characterisation and on-site tests. Moreover, it must outline a suitable accuracy of the geometry to establish a structural numerical model, essential to perform risk assessment [23,24]. Considering these objectives, the geometry definition should be sufficient to support preventive conservation, inform the structural model and cover all relevant constructive elements of the building. Normally, a very detailed geometry is not necessary for this purpose, which reduces the cost of this phase and allows for easier updating by operators with basic knowledge in the field [25]. Thus, this methodology proposes a definition of a geometry based on the native elements offered by the BIM software whenever possible and creates specific elements only when necessary. To complement this information, the point cloud is incorporated into the model to contrast and consult detailed information on the geometry. The model also integrates alphanumeric information essential for the characterisation of each instance. To this end, a series of parameters are established that include historical information, material specifications and structural characteristics. The defined parameters are based
Heritage 2024,73473 on a proposal made within a previous project aiming at a standardised and replicable approach [14]. In order to describe localised damage to specific architectural elements, a specialised model object is proposed. Similar approaches have been implemented in a BIM environment for various data storage and communication purposes, as in [ 14 , 16 , 26 ]. Here, the definition of a cost-effective methodology is attempted by balancing clarity and complexity to foster its generalisation. The placeholder object is a parallelepiped linked to the affected element and located within the affected area that collects a series of features starting from the class of alteration according to the ICOMOS glossary stone deterioration patterns [ 27 ] and the HeritageCare damage atlas [ 28 ]. Additional alphanumeric information detailing the nature of the damage is stored, together with linked graphic information in the form of photographs or other graphic formats. For damage affecting structural elements globally, a simplified approach is used. Damage descriptions are directly linked to the specific component, which provides a simple means of incorporating information related to structural deficiencies. This dual approach is adapted to the diverse nature of the alterations, offering a flexible but comprehensive methodology to capture and represent the state of conservation of the building. To ensure a straightforward communication of the actual conditions to non-technical users, leveraging the navigable and visual nature of the model, damage maps created from orthophotos can be applied as superficial layers to the elements. This approach enhances the more detailed but schematic information provided by the damage-related objects and parameters with a graphical support for the stakeholders. A similar solution is proposed to communicate the main results of on-site nondestructive testing, placing parallelepipeds on the analysed element within the specific area of the test. Standardised information regarding the type of test, its planning, execution and main results obtained are embedded in such objects. The results of the consecutive tests are stored in a data sheet associated with the object, assigning the last result to the parallelepiped. This approach not only streamlines the retrieval of previous test data but also lays the foundation for future comparative analysis, allowing for monitoring of structural integrity over time and an evaluation of the effectiveness of implemented remedial measures. In case other graphical or alphanumerical information is available, this can be included in a similar way, defining standardised ad hoc objects with a simple geometrical shape linked to the information, for consulting during the navigation of the model. For example, when 360 ◦ views are available, a sphere located at the image capture point is used, containing the information of the 360◦view [16]. Once the information from the surveys is integrated into the BIM environment, a second phase of the process is proposed: the definition of a numerical model for structural assessment. This part of the methodology is crucial for a thorough risk assessment that requires simulating hazard scenarios and analysing the structural response to them. Therefore, the methodology envisages the definition of a finite element method (FEM) model to evaluate the non-linear behaviour of the structure under seismic action among other anticipated events. The model is used to assess the vulnerability of the structure and determines the need for interventions if mitigation measures against natural or human-induced hazards are considered necessary. If dynamic information about the building is obtained during on-site testing, commonly through ambient vibration tests, the proposed methodology comprises the calibration of the aforementioned structural model. This calibration not only enhances the accuracy of the results obtained from seismic analysis but also provides a digital replica of the structural behaviour that can be further updated upon the acquisition of new information and/or as part of a continuous SHM (Structural Health Monitoring) system. This anticipated combination of the virtual replica in an HBIM environment and connectivity to the monitoring system and FEM simulations constitutes the digital twin of the building that can evolve over time together with the real counterpart [7,29].
Heritage 2024,73474 This method is currently being applied to the church of Santa Ana in Seville, and its application is presented in the following sections to illustrate the methodology in detail. As of now, the implementation has progressed to the definition of the numerical model, including the calibration phase. Future work entails defining and implementing the monitoring system. 3. Santa Ana Church The church of Santa Ana in Seville (Spain) is selected as the case study to support the validation and testing of the methodology envisaged in this paper. Its architectural and constructive features make this building a suitable and significant case study, being representative of many of the religious buildings in southern Spain, an area that presents a moderate seismic hazard and many heritage assets. 3.1. Historical Context The historical context in which the church of Santa Ana was built is marked by the conquest of Seville by the troops of Fernando III of Castile in 1248. This led to a period of Christianisation in the city, in which the existing mosques were transformed into churches. Indeed, churches were organisms from which not only purely religious functions were exercised, but also different functions of social and territorial organisation. In parallel, another system was introduced, as the conquered territory was handed over to the nobility, the clergy and those who had helped the king, as well as to new settlers. Upon this initiative, the territory on the shore of the river opposite the main settlement of the city, known as Triana, began to grow in importance. Due to this growth, the existing church in this area became insufficient, and it was decided to build a new church, namely, Santa Ana church, Figure 1. Heritage 2024, 7 3474 anticipated combination of the virtual replica in an HBIM environment and connectivity to the monitoring system and FEM simulations constitutes the digital twin of the building that can evolve over time together with the real counterpart [7,29]. This method is currently being applied to the church of Santa Ana in Seville, and its application is presented in the following sections to illustrate the methodology in detail. As of now, the implementation has progressed to the definition of the numerical model, including the calibration phase. Future work entails defining and implementing the monitoring system. 3. Santa Ana Church The church of Santa Ana in Seville (Spain) is selected as the case study to support the validation and testing of the methodology envisaged in this paper. Its architectural and constructive features make this building a suitable and significant case study, being representative of many of the religious buildings in southern Spain, an area that presents a moderate seismic hazard and many heritage assets. 3.1. Historical Context The historical context in which the church of Santa Ana was built is marked by the conquest of Seville by the troops of Fernando III of Castile in 1248. This led to a period of Christianisation in the city, in which the existing mosques were transformed into churches. Indeed, churches were organisms from which not only purely religious functions were exercised, but also different functions of social and territorial organisation. In parallel, another system was introduced, as the conquered territory was handed over to the nobility, the clergy and those who had helped the king, as well as to new settlers. Upon this initiative, the territory on the shore of the river opposite the main settlement of the city, known as Triana, began to grow in importance. Due to this growth, the existing church in this area became insufficient, and it was decided to build a new church, namely, Santa Ana church, Figure 1. Figure 1. General view of Seville. Author Ambrosius Brambilla 1585. Santa Ana church is marked with a circle. National library of Spain. Therefore, Santa Ana plays a rather important role in the history of Seville, being the first church built from the ground up without using an existing mosque as a base. Located outside the walls of the city, on the shore of the Guadalquivir River, it has a marked Figure 1. General view of Seville. Author Ambrosius Brambilla 1585. Santa Ana church is marked with a circle. National library of Spain. Therefore, Santa Ana plays a rather important role in the history of Seville, being the first church built from the ground up without using an existing mosque as a base. Located outside the walls of the city, on the shore of the Guadalquivir River, it has a marked defensive character due to its position at the foot of the Aljarafe cornice, where constant attacks by the Muslims expelled from the city were taking place.
Heritage 2024,73475 Alfonso X succeeded to the throne after Fernando III’s death. Under his reign, the construction of the primitive church began in 1266, according to the historian JoséGestoso y Pérez, or in 1280, according to the historian Ortiz de Zúñiga [ 30 ]. The complex was erected practically without interruption according to the planned layout, taking several years and at a slow pace due to the scarcity of resources. The building has peculiar characteristics due not only to its defensive nature but also to the combination of the Gothic style imported from Castilla and the Muslim Almohad style, which lasted even through the reconquest [ 31 ]. This mix of styles is called Mudejar. In addition, upon its original construction, the building has undergone numerous modifications and interventions over the years, so that its current state has not only Mudejar features but also Renaissance and Baroque ones. Several reasons for the interventions have been identified, including those carried out after natural catastrophes that damaged the building, such as floods, fires and mainly earthquakes, among which the earthquakes of 1356 and 1755 were particularly severe. 3.2. General Description The church of Santa Ana is a rectangular building with three naves of five bays and one apse, namely, the Gospel nave on the left, the main nave in the centre and the Epistle nave on the right. The central nave is larger both in plan and height. However, the height of the side naves is very similar to the central one, because the roof is accessible through the tower due to its defensive nature. Therefore, the roof presents minimal slope, and its finishing layer is made of solid bricks (Figure 2). Heritage 2024, 7 3475 defensive character due to its position at the foot of the Aljarafe cornice, where constant attacks by the Muslims expelled from the city were taking place. Alfonso X succeeded to the throne after Fernando III’s death. Under his reign, the construction of the primitive church began in 1266, according to the historian José Gestoso y Pérez, or in 1280, according to the historian Ortiz de Zúñiga [30]. The complex was erected practically without interruption according to the planned layout, taking several years and at a slow pace due to the scarcity of resources. The building has peculiar characteristics due not only to its defensive nature but also to the combination of the Gothic style imported from Castilla and the Muslim Almohad style, which lasted even through the reconquest [31]. This mix of styles is called Mudejar. In addition, upon its original construction, the building has undergone numerous modifications and interventions over the years, so that its current state has not only Mudejar features but also Renaissance and Baroque ones. Several reasons for the interventions have been identified, including those carried out after natural catastrophes that damaged the building, such as floods, fires and mainly earthquakes, among which the earthquakes of 1356 and 1755 were particularly severe. 3.2. General Description The church of Santa Ana is a rectangular building with three naves of five bays and one apse, namely, the Gospel nave on the left, the main nave in the centre and the Epistle nave on the right. The central nave is larger both in plan and height. However, the height of the side naves is very similar to the central one, because the roof is accessible through the tower due to its defensive nature. Therefore, the roof presents minimal slope, and its finishing layer is made of solid bricks (Figure 2). Figure 2. Aerial view of the church. Main and Gospel nave façade. Despite the imperfections that occurred during construction, it can be seen that the columns are arranged according to a regular grid. The dimension of the church is about 44 varas long. Vara was a common unit of measurement, known first as the vara burgalesa and later as the vara castellana and corresponding to 83.59 cm. Therefore, the approximate length of the naves is about 37 m. The columns of the naves support pointed arches that separate the naves. A gallery is located within the walls above the arches, and between these and the lateral walls are the ribbed vaults that cover the naves, Figure 3. There is no information on the filling of these vaults, so it is estimated that there is a structural infill up to half of the vault, and that the remaining space is filled with poor material. The passable roof on top of this poor infill was intervened in one of the last renovations, when a concrete slab was created; however, detailed information about it was not found. Figure 2. Aerial view of the church. Main and Gospel nave façade. Despite the imperfections that occurred during construction, it can be seen that the columns are arranged according to a regular grid. The dimension of the church is about 44 varas long. Vara was a common unit of measurement, known first as the vara burgalesa and later as the vara castellana and corresponding to 83.59 cm. Therefore, the approximate length of the naves is about 37 m. The columns of the naves support pointed arches that separate the naves. A gallery is located within the walls above the arches, and between these and the lateral walls are the ribbed vaults that cover the naves, Figure 3. There is no information on the filling of these vaults, so it is estimated that there is a structural infill up to half of the vault, and that the remaining space is filled with poor material. The passable roof on top of this poor infill was intervened in one of the last renovations, when a concrete slab was created; however, detailed information about it was not found. There are three entrances to the church, namely, a central portal on the main façade and one portal on each side, giving access to the lateral naves. The tower is attached to the left side of the façade and was probably crenellated at the top, given the defensive nature of the building.
Heritage 2024,73476 Heritage 2024, 7 3476 Figure 3. Interior of the church, main altar. There are three entrances to the church, namely, a central portal on the main façade and one portal on each side, giving access to the lateral naves. The tower is attached to the left side of the façade and was probably crenellated at the top, given the defensive nature of the building. The crypt is located under the Epistle nave and accessed through the Calvary Chapel. This is a longitudinal space covered by a barrel vault with a pointed arch that occupies almost the entire surface of the nave. Under the Gospel nave, there is access through a hole in the floor to a space also covered by a barrel vault. At the time of the construction of the church of Santa Ana, stones were scarce in the area of Seville and very expensive. Therefore, masonry was commonly made of bricks. Indeed, most of Santa Ana is made of bricks, reserving the use of stone for the ribs of the vaults, arches, small columns, doorways and for those areas where greater strength was required, such as in the connection of the chancel with the body of the naves and the lower level of the tower. The stone blocks are made of calcarenite rock, likely from the Sierra de San Cristóbal [32]. Mortar is lime-based and arranged in joints of considerable thickness, except for the stone vaults and the ribs, where thinner joints are present. 3.3. Evolution and Modifications over Time From the construction of the original church to the present day, the geometry has undergone several alterations. The original plan consisted of a body with three naves of five bays and the apse, as shown in Figure 4a. In the middle of the 14th century, the construction of the first part of the tower began. In 1499, the Calvary Chapel was built, occupying the apse of the Epistle nave. Around 1505, the Capitan Monte Bernardo Chapel was annexed to the Gospel nave in the fourth bay next to the portal. In 1507, opposite the Chapel of Captain Monte Bernardo, the Chapel of Santa Bárbara was annexed to the Epistle nave. In the middle of the 16th century, the Sacramental Chapel was built in the second section of the Gospel nave, Figure 4b. In 1570, the Chapel of San Francisco was finished, partially occupying the last section of the Gospel nave. Symmetrically, in 1591, the Chapel of the Souls was built partially occupying the bay of the Epistle nave. At the end of the 16th century, the Chapel of San Joaquín was constructed in the second bay of the Epistle nave. Between 1614 and 1617, the Baptismal Chapel was built, next to the Chapel of Captain Monte Bernardo. In 1629, the construction of the second section of the tower and the pyramidal spire was carried out. Around 1865, the Chapel of the Divina Pastora was built in the last section of the Epistle nave. This configuration is shown in Figure 4c. From 1993 onwards, works were carried out in the Sacristy courtyard [33]. Figure 3. Interior of the church, main altar. The crypt is located under the Epistle nave and accessed through the Calvary Chapel. This is a longitudinal space covered by a barrel vault with a pointed arch that occupies almost the entire surface of the nave. Under the Gospel nave, there is access through a hole in the floor to a space also covered by a barrel vault. At the time of the construction of the church of Santa Ana, stones were scarce in the area of Seville and very expensive. Therefore, masonry was commonly made of bricks. Indeed, most of Santa Ana is made of bricks, reserving the use of stone for the ribs of the vaults, arches, small columns, doorways and for those areas where greater strength was required, such as in the connection of the chancel with the body of the naves and the lower level of the tower. The stone blocks are made of calcarenite rock, likely from the Sierra de San Cristóbal [ 32 ]. Mortar is lime-based and arranged in joints of considerable thickness, except for the stone vaults and the ribs, where thinner joints are present. 3.3. Evolution and Modifications over Time From the construction of the original church to the present day, the geometry has undergone several alterations. The original plan consisted of a body with three naves of five bays and the apse, as shown in Figure 4a. In the middle of the 14th century, the construction of the first part of the tower began. In 1499, the Calvary Chapel was built, occupying the apse of the Epistle nave. Around 1505, the Capitan Monte Bernardo Chapel was annexed to the Gospel nave in the fourth bay next to the portal. In 1507, opposite the Chapel of Captain Monte Bernardo, the Chapel of Santa Bárbara was annexed to the Epistle nave. In the middle of the 16th century, the Sacramental Chapel was built in the second section of the Gospel nave, Figure 4b. In 1570, the Chapel of San Francisco was finished, partially occupying the last section of the Gospel nave. Symmetrically, in 1591, the Chapel of the Souls was built partially occupying the bay of the Epistle nave. At the end of the 16th century, the Chapel of San Joaquín was constructed in the second bay of the Epistle nave. Between 1614 and 1617, the Baptismal Chapel was built, next to the Chapel of Captain Monte Bernardo. In 1629, the construction of the second section of the tower and the pyramidal spire was carried out. Around 1865, the Chapel of the Divina Pastora was built in the last section of the Epistle nave. This configuration is shown in Figure 4c. From 1993 onwards, works were carried out in the Sacristy courtyard [33].
Heritage 2024,73477 Heritage 2024, 7 3477 Figure 4. Evolution of the plans from the original design until the mid-19th century: (a) original plan, (b) mid-16th century, (c) mid-19th century. Grey: original plant, dark red: new modifications, light red: previous modifications. Adapted from [33]. 3.4. Seismic Hazard Taking into account the information collected from past earthquakes and the geological characteristics, the Spanish territory is divided into five seismic areas, as shown in the seismic hazard map (Figure 5). The Spanish seismic norm [34,35] defines the peak ground acceleration value for Seville as 0.09 g. Figure 5. Seismic hazard map of Spain, Seville marked with a blue dot [35]. Although the seismic hazard of the area where the church is located is not one of the highest, Seville has historically suffered at least five major earthquakes, causing significant structural damage to the building stock, including Santa Ana church [30,36], as summarised in Table 1. Figure 4. Evolution of the plans from the original design until the mid-19th century: (a) original plan, (b) mid-16th century, (c) mid-19th century. Grey: original plant, dark red: new modifications, light red: previous modifications. Adapted from [33]. 3.4. Seismic Hazard Taking into account the information collected from past earthquakes and the geological characteristics, the Spanish territory is divided into five seismic areas, as shown in the seismic hazard map (Figure 5). The Spanish seismic norm [ 34 , 35 ] defines the peak ground acceleration value for Seville as 0.09 g. Heritage 2024, 7 3477 Figure 4. Evolution of the plans from the original design until the mid-19th century: (a) original plan, (b) mid-16th century, (c) mid-19th century. Grey: original plant, dark red: new modifications, light red: previous modifications. Adapted from [33]. 3.4. Seismic Hazard Taking into account the information collected from past earthquakes and the geological characteristics, the Spanish territory is divided into five seismic areas, as shown in the seismic hazard map (Figure 5). The Spanish seismic norm [34,35] defines the peak ground acceleration value for Seville as 0.09 g. Figure 5. Seismic hazard map of Spain, Seville marked with a blue dot [35]. Although the seismic hazard of the area where the church is located is not one of the highest, Seville has historically suffered at least five major earthquakes, causing significant structural damage to the building stock, including Santa Ana church [30,36], as summarised in Table 1. Figure 5. Seismic hazard map of Spain, Seville marked with a blue dot [35]. Although the seismic hazard of the area where the church is located is not one of the highest, Seville has historically suffered at least five major earthquakes, causing significant structural damage to the building stock, including Santa Ana church [ 30 , 36 ], as summarised in Table 1.
Heritage 2024,73478 Table 1. Summary of earthquakes affecting Seville. Date Epicentre Reported Damage Seville Reported Damage/ Interventions at Santa Ana Church 24 August 1356 Offshore Cape St. Vincent Fall of elements from minaret tower, Great Mosque (actual Cathedral) Reconstruction of arches of the bays next to the apses 5 April 1504 Carmona Several houses and churches collapsed in the region Unknown 1 November 1755 Offshore Cape St. Vincent Around 300 houses collapsed, with 5000 severely damaged in Seville. Major damage to Cathedral tower, main vaults and roofs Collapse of the vault above the choir. Reconstruction of the main portal 1 August 1888 Unknown Collapse of a pillar and second dome of the Cathedral, severe damage to the transept Unknown 28 February 1969 Offshore Cape St. Vincent Severe damage to Cathedral, City Hall, Torre del Oro, Alcázar and Museum of Fine Arts Unknown 4. Inspection A detailed inspection of the church of Santa Ana was carried out, aiming at a geometrical survey, structural system inspection, material characterisation, dynamic identification and damage mapping to support the following structural assessment and diagnosis. Activities conducted on site are hereafter discussed. 4.1. Geometrical Survey Photogrammetry is the geometric data acquisition technique used for this application. This technique stands out for its accessibility; the technique requires minimal equipment and expertise and delivers high-resolution models [8,37]. A photogrammetric survey of the church was carried out, and a 3D model of the exterior and interior was generated through Agisoft Metashape 1.8.4. software [ 38 ]. A Sony ILCE-6000 digital camera with 42 MP was used for the collection of images. The photos were acquired with a fixed focal length of 16 mm. The model of the external part is based on 459 photos taken from the streets around the church, Figure 6. Due to the unavailability of a drone, the roof has not been included in the model. Reference measurements taken in situ were used to scale the model. Several representative points were considered, including different sections, angles and directions. The final model was validated based on these measurements. The ground sampling distance (GSD) value is 2.19 mm/pix for this model. Heritage 2024, 7 3479 Figure 6. Photogrammetric model of the exterior of the church. For the interior model, the same equipment and methodology was used. This model, composed of more than 280 photos, presented higher complexity due to the geometry and the details of the architectural decorations, the spatial configuration and all the artistic elements and furniture. Furthermore, problems related to non-optimal lighting conditions inside the church were addressed. In this case, the obtained GSD value is 2.39 mm/pix. A horizontal section of the model linking external and internal geometry is shown in Figure 7. A more refined model of the transversal arches that connect the third and fourth bays from the façade was generated for structural analysis and condition assessment purposes. This allowed for the obtainment of a more detailed geometry of the vaults and identification of the deformation of columns and arches (Figure 8). Figure 7. Exterior and interior photogrammetric models’ horizontal cross section. Figure 8. Photogrammetric model of a transversal arch. Figure 6. Photogrammetric model of the exterior of the church.
Heritage 2024,73485 local modes of vibration of the tower. The third is a transversal bending mode of the nave that also involves the tower in counterphase. The fourth is longitudinal, whereas the fifth is torsional. Finally, a local vertical mode of the roof is the sixth identified. Heritage 2024, 7 3485 The accelerometers were connected to a 36-channel data acquisition system with an analogue-to-digital converter (Obsidiana 36× model). For each acquisition, a sampling rate of 50 Hz and a duration of 20 min were set. The data obtained in situ were processed with ARTeMIS Modal 7.0 software [45] using a well-established estimator: the Enhanced Frequency Domain Decomposition (EFDD). For a clearer insight into the dynamic behaviour of the building, two models were defined. One aimed at the global analysis of the structure, including all the measurement points except the two located in the galleries of the longitudinal arcades. The results of the first model are shown in Figure 17. In particular, six modes were identified. The first two are local modes of vibration of the tower. The third is a transversal bending mode of the nave that also involves the tower in counterphase. The fourth is longitudinal, whereas the fifth is torsional. Finally, a local vertical mode of the roof is the sixth identified. The second model aimed at the analysis of a single transversal section, thus including a total of seven measurement points, comprising setup 07 and some sensors from setup 09. The results of this second model are shown in Figure 18. Except for the first mode of the tower, the remaining five modes are identified in the second model as well, with similar frequency values. Figure 17. Six experimental vibration modes of the global model. Figure 18. Five experimental modes of the portico model. 5. HBIM Model The virtual replica in the HBIM environment was developed, aiming at a seamless integration of the information collected during the ongoing investigation, including upon future expansion of knowledge, through graphical and non-graphical modelled data. This specific case study employs Revit 2024 recasoftware [46] for this purpose. However, the adopted methodology is independent of the specific software utilised. The first step of the methodology aims to model the geometry of the structure based on existing drawings and on-site measurements, supplemented with the extensive point cloud information derived from the photogrammetric model. This point cloud, processed with Autodesk ReCap 2024 software [47] and subsequently exported to a Revit-compatible Figure 17. Six experimental vibration modes of the global model. The second model aimed at the analysis of a single transversal section, thus including a total of seven measurement points, comprising setup 07 and some sensors from setup 09. The results of this second model are shown in Figure 18. Except for the first mode of the tower, the remaining five modes are identified in the second model as well, with similar frequency values. Heritage 2024, 7 3485 The accelerometers were connected to a 36-channel data acquisition system with an analogue-to-digital converter (Obsidiana 36× model). For each acquisition, a sampling rate of 50 Hz and a duration of 20 min were set. The data obtained in situ were processed with ARTeMIS Modal 7.0 software [45] using a well-established estimator: the Enhanced Frequency Domain Decomposition (EFDD). For a clearer insight into the dynamic behaviour of the building, two models were defined. One aimed at the global analysis of the structure, including all the measurement points except the two located in the galleries of the longitudinal arcades. The results of the first model are shown in Figure 17. In particular, six modes were identified. The first two are local modes of vibration of the tower. The third is a transversal bending mode of the nave that also involves the tower in counterphase. The fourth is longitudinal, whereas the fifth is torsional. Finally, a local vertical mode of the roof is the sixth identified. The second model aimed at the analysis of a single transversal section, thus including a total of seven measurement points, comprising setup 07 and some sensors from setup 09. The results of this second model are shown in Figure 18. Except for the first mode of the tower, the remaining five modes are identified in the second model as well, with similar frequency values. Figure 17. Six experimental vibration modes of the global model. Figure 18. Five experimental modes of the portico model. 5. HBIM Model The virtual replica in the HBIM environment was developed, aiming at a seamless integration of the information collected during the ongoing investigation, including upon future expansion of knowledge, through graphical and non-graphical modelled data. This specific case study employs Revit 2024 recasoftware [46] for this purpose. However, the adopted methodology is independent of the specific software utilised. The first step of the methodology aims to model the geometry of the structure based on existing drawings and on-site measurements, supplemented with the extensive point cloud information derived from the photogrammetric model. This point cloud, processed with Autodesk ReCap 2024 software [47] and subsequently exported to a Revit-compatible Figure 18. Five experimental modes of the portico model. 5. HBIM Model The virtual replica in the HBIM environment was developed, aiming at a seamless integration of the information collected during the ongoing investigation, including upon future expansion of knowledge, through graphical and non-graphical modelled data. This specific case study employs Revit 2024 recasoftware [ 46 ] for this purpose. However, the adopted methodology is independent of the specific software utilised. The first step of the methodology aims to model the geometry of the structure based on existing drawings and on-site measurements, supplemented with the extensive point cloud information derived from the photogrammetric model. This point cloud, processed with Autodesk ReCap 2024 software [ 47 ] and subsequently exported to a Revit-compatible format, served as a fundamental reference for the modelling process, especially for the more complex shapes such as the nave vaults and altar vaults. In the delineation of the architectural elements, native parametric families were mainly used, which covered a spectrum of components such as walls, columns, floor slabs and roof systems. This simplifies the process and saves time; however, the complex nature of the building architecture necessitated the development of custom families tailored to the peculiar features of some of the components, such as the intricate vaults, as shown in Figure 19.
Heritage 2024,73486 Heritage 2024, 7 3486 format, served as a fundamental reference for the modelling process, especially for the more complex shapes such as the nave vaults and altar vaults. In the delineation of the architectural elements, native parametric families were mainly used, which covered a spectrum of components such as walls, columns, floor slabs and roof systems. This simplifies the process and saves time; however, the complex nature of the building architecture necessitated the development of custom families tailored to the peculiar features of some of the components, such as the intricate vaults, as shown in Figure 19. Figure 19. BIM parametric objects adopted in the project: examples of native ones in green; in orange, new ones created ad hoc. As mentioned above, the level of geometric detail of the model was defined in order to ensure a representation of the correct dimensions of the building as well as the structural components, simplifying their details whenever possible and neglecting the decorative and artistic elements. To incorporate the information discussed in Section 3 on the analysis of the alignment of the elements with the theoretical horizontal and vertical planes, the point cloud is kept linked to the model to be queried and navigated whenever needed, Figure 20. Figure 20. Comparison of the idealised geometry and the point cloud. Figure 19. BIM parametric objects adopted in the project: examples of native ones in green; in orange, new ones created ad hoc. As mentioned above, the level of geometric detail of the model was defined in order to ensure a representation of the correct dimensions of the building as well as the structural components, simplifying their details whenever possible and neglecting the decorative and artistic elements. To incorporate the information discussed in Section 3on the analysis of the alignment of the elements with the theoretical horizontal and vertical planes, the point cloud is kept linked to the model to be queried and navigated whenever needed, Figure 20. Heritage 2024, 7 3486 format, served as a fundamental reference for the modelling process, especially for the more complex shapes such as the nave vaults and altar vaults. In the delineation of the architectural elements, native parametric families were mainly used, which covered a spectrum of components such as walls, columns, floor slabs and roof systems. This simplifies the process and saves time; however, the complex nature of the building architecture necessitated the development of custom families tailored to the peculiar features of some of the components, such as the intricate vaults, as shown in Figure 19. Figure 19. BIM parametric objects adopted in the project: examples of native ones in green; in orange, new ones created ad hoc. As mentioned above, the level of geometric detail of the model was defined in order to ensure a representation of the correct dimensions of the building as well as the structural components, simplifying their details whenever possible and neglecting the decorative and artistic elements. To incorporate the information discussed in Section 3 on the analysis of the alignment of the elements with the theoretical horizontal and vertical planes, the point cloud is kept linked to the model to be queried and navigated whenever needed, Figure 20. Figure 20. Comparison of the idealised geometry and the point cloud. Figure 20. Comparison of the idealised geometry and the point cloud. As mentioned in the definition of the methodology, the damage information obtained from the survey was incorporated into the model in three different ways, as visual damage maps applied as superficial layers and as information either included in the element when global or embedded in ad hoc object when localised. In what concerns the damage maps, high-resolution orthophotos have been attached to the interior perimeter walls and the arcades. Regarding the localised damage, specific objects have been created for the two main types of damage present in the church, cracks and moisture stains.
Heritage 2024,73487 The parallelepipeds for the on-site non-destructive testing have been placed in the area where the test was performed. The placeholders for the sonic test include the information presented in Table 4. Similarly, the location of the accelerometers during the dynamic tests was reported by introducing an object including the specification of the sensor, the number assigned and the setup in which they were recorded, as well as the results of the test. In addition, the model incorporates useful 360 ◦ views that enrich the HBIM model with immersive visual data. For this purpose, a third object was defined, a sphere located at the image capture point. Figure 21 shows the implementation of these elements in the model. Heritage 2024, 7 3487 As mentioned in the definition of the methodology, the damage information obtained from the survey was incorporated into the model in three different ways, as visual damage maps applied as superficial layers and as information either included in the element when global or embedded in ad hoc object when localised. In what concerns the damage maps, high-resolution orthophotos have been attached to the interior perimeter walls and the arcades. Regarding the localised damage, specific objects have been created for the two main types of damage present in the church, cracks and moisture stains. The parallelepipeds for the on-site non-destructive testing have been placed in the area where the test was performed. The placeholders for the sonic test include the information presented in Table 4. Similarly, the location of the accelerometers during the dynamic tests was reported by introducing an object including the specification of the sensor, the number assigned and the setup in which they were recorded, as well as the results of the test. In addition, the model incorporates useful 360° views that enrich the HBIM model with immersive visual data. For this purpose, a third object was defined, a sphere located at the image capture point. Figure 21 shows the implementation of these elements in the model. Figure 21. Section of the 3D model showing the parametric objects that includes no geometric information of the model. 6. Numerical Model For the structural analysis of the building, DIANA FEA [48] has been chosen. First, a high-fidelity model is generated and used for condition monitoring, Figure 22a. This model represents the actual dynamic behaviour of the structure under low vibration actions, serving as a reliable basis for an envisaged automatic damage identification strategy coupled with a continuous monitoring system. In this context, the focus is on the monitoring of the modal properties of the building under ambient excitation (OMA). To this end, a model is built and updated based on the modal identification campaign data. Then, a second model is defined to investigate the seismic vulnerability of the church, Figure 22b. The assumptions considered in this model differ from the previous one, as the goal is to analyse the behaviour under a larger amplitude of vibrations caused by an earthquake. This is expected to induce moderate–severe damage and, in general, a non-linear response of the structure significantly different from the one caused by environmental excitations (linear behaviour and very low amplitude of the actions). For the definition of this second model, some simplifications are made, namely, the infill and the concrete deck slab are included in the model as mass (equivalent density in the vaults and the Figure 21. Section of the 3D model showing the parametric objects that includes no geometric information of the model. 6. Numerical Model For the structural analysis of the building, DIANA FEA [ 48 ] has been chosen. First, a high-fidelity model is generated and used for condition monitoring, Figure 22a. This model represents the actual dynamic behaviour of the structure under low vibration actions, serving as a reliable basis for an envisaged automatic damage identification strategy coupled with a continuous monitoring system. In this context, the focus is on the monitoring of the modal properties of the building under ambient excitation (OMA). To this end, a model is built and updated based on the modal identification campaign data. Heritage 2024, 7 3488 longitudinal walls), without geometric and stiffness representation, due to the lack of information on the constructive details and the quality of connection with the side walls. (a) (b) Figure 22. FEM model of Santa Ana church: (a) high-fidelity model; (b) simplified model. Modelling the infill and the concrete deck slab as physical objects can result in a significant increase in the stiffness when assuming medium/good material properties and connections to the side walls, leading to a box behaviour that increases the structural strength and likely overestimates the structure capacity. On the other hand, the low material properties of the infill and weak connections to the side walls cause excessive damage under self-weight only, unobserved in the real structure, which prevents a correct execution of the non-linear analysis. 6.1. Calibration of the High-Fidelity Model The high-fidelity model geometry was defined based on the data included in the HBIM. Then, the modal properties obtained from the dynamic identification test were used for calibration, by updating the values of a set of variables in order to match numerical and experimental response [49,50]. To this end, a preliminary sensitivity analysis of the influence of the variables on the numerical estimation of the dynamic properties was carried out. From the initial fourteen variables considered, a final set of nine properties was considered for the calibration, Figure 23. Table 5 shows the final updated values. It is worth noting that the degree of connection between the tower and the nave is included, since a rigid connection failed at reproducing the dynamic behaviour of the tower as identified in the experimental test, especially for the shape of the local modes, first and second, and the counterphase vibration of the tower and the nave in the third mode. Table 5. Variables of the FEM model calibration process. Initial and updated values. Element Variable Initial Value Updated Value Tower (Tw) Youngs’s modulus [MPa] 1500 1150 Ext. walls Youngs’s modulus [MPa] 1500 1150 Int. arches Youngs’s modulus [MPa] 1500 1150 Vaults Youngs’s modulus [MPa] 1500 1300 Poor infill Youngs’s modulus [MPa] 25 110 Roof slab Youngs’s modulus [MPa] 25,000 35,000 Chapels walls Youngs’s modulus [MPa] 1500 1000 Tw-nave A Connection [MPa m] connected 14 Tw-nave B Connection [MPa m] connected 10 Tw-chapels Connection [MPa m] connected 100 Figure 22. FEM model of Santa Ana church: (a) high-fidelity model; (b) simplified model.
Heritage 2024,73488 Then, a second model is defined to investigate the seismic vulnerability of the church, Figure 22b. The assumptions considered in this model differ from the previous one, as the goal is to analyse the behaviour under a larger amplitude of vibrations caused by an earthquake. This is expected to induce moderate–severe damage and, in general, a nonlinear response of the structure significantly different from the one caused by environmental excitations (linear behaviour and very low amplitude of the actions). For the definition of this second model, some simplifications are made, namely, the infill and the concrete deck slab are included in the model as mass (equivalent density in the vaults and the longitudinal walls), without geometric and stiffness representation, due to the lack of information on the constructive details and the quality of connection with the side walls. Modelling the infill and the concrete deck slab as physical objects can result in a significant increase in the stiffness when assuming medium/good material properties and connections to the side walls, leading to a box behaviour that increases the structural strength and likely overestimates the structure capacity. On the other hand, the low material properties of the infill and weak connections to the side walls cause excessive damage under self-weight only, unobserved in the real structure, which prevents a correct execution of the non-linear analysis. 6.1. Calibration of the High-Fidelity Model The high-fidelity model geometry was defined based on the data included in the HBIM. Then, the modal properties obtained from the dynamic identification test were used for calibration, by updating the values of a set of variables in order to match numerical and experimental response [ 49 , 50 ]. To this end, a preliminary sensitivity analysis of the influence of the variables on the numerical estimation of the dynamic properties was carried out. From the initial fourteen variables considered, a final set of nine properties was considered for the calibration, Figure 23. Table 5shows the final updated values. It is worth noting that the degree of connection between the tower and the nave is included, since a rigid connection failed at reproducing the dynamic behaviour of the tower as identified in the experimental test, especially for the shape of the local modes, first and second, and the counterphase vibration of the tower and the nave in the third mode. Heritage 2024, 7 3489 Figure 23. Elements of the model involved in the calibration. The closeness between numerically predicted modal properties and experimental results is qualitatively demonstrated through the comparison of the shapes, mainly in the first four modes, plotted in Figure 24. Moreover, it is assessed both in terms of relative error of the natural frequencies and modal assurance criterion (MAC), as reported in Table 6. The connection between the tower and the nave governs the behaviour in the first two modes. The third mode is sensitive to the connection with the tower but also to the masonry properties of the vertical elements, as are modes four and five. The slab and the infill mechanical properties play a relevant role in mode six, having some influence in the third mode too. Figure 24. Comparison of dynamic properties of the experimental (OMA) and numerical model (FEM). Chapels of the numerical model hidden for a clearer visual comparison. Table 6. Experimental and numerical frequencies and MAC comparison. Mode Experimental Frequency [Hz] Numerical Frequency [Hz] Frequency Error [%] MAC Mode 1 1.80 1.79 −0.4 0.96 Mode 2 1.92 1.93 0.3 0.89 Mode 3 2.37 2.36 −0.5 0.97 Mode 4 3.55 3.58 1.0 0.91 Mode 5 3.87 4.09 5.7 0.44 Mode 6 4.27 4.23 −0.9 0.50 Figure 23. Elements of the model involved in the calibration.
Heritage 2024,73489 Table 5. Variables of the FEM model calibration process. Initial and updated values. Element Variable Initial Value Updated Value Tower (Tw) Youngs’s modulus [MPa] 1500 1150 Ext. walls Youngs’s modulus [MPa] 1500 1150 Int. arches Youngs’s modulus [MPa] 1500 1150 Vaults Youngs’s modulus [MPa] 1500 1300 Poor infill Youngs’s modulus [MPa] 25 110 Roof slab Youngs’s modulus [MPa] 25,000 35,000 Chapels walls Youngs’s modulus [MPa] 1500 1000 Tw-nave A Connection [MPa m] connected 14 Tw-nave B Connection [MPa m] connected 10 Tw-chapels Connection [MPa m] connected 100 The closeness between numerically predicted modal properties and experimental results is qualitatively demonstrated through the comparison of the shapes, mainly in the first four modes, plotted in Figure 24. Moreover, it is assessed both in terms of relative error of the natural frequencies and modal assurance criterion (MAC), as reported in Table 6. The connection between the tower and the nave governs the behaviour in the first two modes. The third mode is sensitive to the connection with the tower but also to the masonry properties of the vertical elements, as are modes four and five. The slab and the infill mechanical properties play a relevant role in mode six, having some influence in the third mode too. Heritage 2024, 7 3489 Figure 23. Elements of the model involved in the calibration. The closeness between numerically predicted modal properties and experimental results is qualitatively demonstrated through the comparison of the shapes, mainly in the first four modes, plotted in Figure 24. Moreover, it is assessed both in terms of relative error of the natural frequencies and modal assurance criterion (MAC), as reported in Table 6. The connection between the tower and the nave governs the behaviour in the first two modes. The third mode is sensitive to the connection with the tower but also to the masonry properties of the vertical elements, as are modes four and five. The slab and the infill mechanical properties play a relevant role in mode six, having some influence in the third mode too. Figure 24. Comparison of dynamic properties of the experimental (OMA) and numerical model (FEM). Chapels of the numerical model hidden for a clearer visual comparison. Table 6. Experimental and numerical frequencies and MAC comparison. Mode Experimental Frequency [Hz] Numerical Frequency [Hz] Frequency Error [%] MAC Mode 1 1.80 1.79 −0.4 0.96 Mode 2 1.92 1.93 0.3 0.89 Mode 3 2.37 2.36 −0.5 0.97 Mode 4 3.55 3.58 1.0 0.91 Mode 5 3.87 4.09 5.7 0.44 Mode 6 4.27 4.23 −0.9 0.50 Figure 24. Comparison of dynamic properties of the experimental (OMA) and numerical model (FEM). Chapels of the numerical model hidden for a clearer visual comparison. Table 6. Experimental and numerical frequencies and MAC comparison. Mode Experimental Frequency [Hz] Numerical Frequency [Hz] Frequency Error [%] MAC Mode 1 1.80 1.79 −0.4 0.96 Mode 2 1.92 1.93 0.3 0.89 Mode 3 2.37 2.36 −0.5 0.97 Mode 4 3.55 3.58 1.0 0.91 Mode 5 3.87 4.09 5.7 0.44 Mode 6 4.27 4.23 −0.9 0.50 6.2. Seismic Analysis The seismic vulnerability assessment was carried out on the second, simplified model by means of non-linear static analysis [ 51 ]. The material model used is a rotating total strainbased crack model, with exponential softening in tension and parabolic in compression. The capacity curves for the four main load distributions (i.e., positive and negative longitudinal X direction and positive and negative transversal Y direction) are plotted in Figure 25. They show horizontal acceleration plotted against the displacement of a defined control point, in this case, the point with maximum displacement for each case [52].
Heritage 2024,73490 Heritage 2024, 7 3490 6.2. Seismic Analysis The seismic vulnerability assessment was carried out on the second, simplified model by means of non-linear static analysis [51]. The material model used is a rotating total strain-based crack model, with exponential softening in tension and parabolic in compression. The capacity curves for the four main load distributions (i.e., positive and negative longitudinal X direction and positive and negative transversal Y direction) are plotted in Figure 25. They show horizontal acceleration plotted against the displacement of a defined control point, in this case, the point with maximum displacement for each case [52]. Figure 25. Capacity curves obtained from the pushover analysis and location of control points. Santa Ana church presents a higher capacity in the longitudinal (X) than in the transversal (Y) direction. Moreover, in the case of the X direction, the maximum displacement is at the top of the tower, whereas in the Y direction, the maximum displacement is placed at the top of the central column of the arcades that divides the central and the lateral naves. For the +Y case, the maximum displacement is located in the arcade between the central and the Gospel nave (left), and in the −Y case, it is in the arcade between the central and the Epistle nave (right). The damage pattern is presented in Figure 26. Analysing the tensile principal strains for +X, the case with the higher capacity load (almost 0.3 g), it is possible to observe the rotation of the tower with a concentration of strains at the base and in the façade, close to the tower. The lateral vaults present shear diagonal cracks, typical for these elements bounded by a central nave with lower stiffness than the external walls. This pattern is also present in −X. However, in this case, the capacity curve shows a lower value, and the damage reached in the longitudinal walls is higher than in the opposite direction. In both cases, cracks in the perpendicular connections between walls are also present. In the transversal direction, the load capacity decreases by more than half (0.12 g). The damage is lower in the +Y direction due to the stiffness provided by the chapels on this side. Conversely, in the opposite orientation, the chapels have a smaller area, closing the space between buttresses with thin walls and without additional walls perpendicular to the façade. The damage pattern here shows cracks in the lateral façades indicating out- of-plane failure and a longitudinal crack at the top of the lateral vault close to that wall. However, the main problem is the collapse mechanism occurring at the points with Figure 25. Capacity curves obtained from the pushover analysis and location of control points. Santa Ana church presents a higher capacity in the longitudinal (X) than in the transversal (Y) direction. Moreover, in the case of the X direction, the maximum displacement is at the top of the tower, whereas in the Y direction, the maximum displacement is placed at the top of the central column of the arcades that divides the central and the lateral naves. For the +Y case, the maximum displacement is located in the arcade between the central and the Gospel nave (left), and in the − Y case, it is in the arcade between the central and the Epistle nave (right). The damage pattern is presented in Figure 26. Analysing the tensile principal strains for +X, the case with the higher capacity load (almost 0.3 g), it is possible to observe the rotation of the tower with a concentration of strains at the base and in the façade, close to the tower. The lateral vaults present shear diagonal cracks, typical for these elements bounded by a central nave with lower stiffness than the external walls. This pattern is also present in − X. However, in this case, the capacity curve shows a lower value, and the damage reached in the longitudinal walls is higher than in the opposite direction. In both cases, cracks in the perpendicular connections between walls are also present. In the transversal direction, the load capacity decreases by more than half (0.12 g). The damage is lower in the +Y direction due to the stiffness provided by the chapels on this side. Conversely, in the opposite orientation, the chapels have a smaller area, closing the space between buttresses with thin walls and without additional walls perpendicular to the façade. The damage pattern here shows cracks in the lateral façades indicating out-of-plane failure and a longitudinal crack at the top of the lateral vault close to that wall. However, the main problem is the collapse mechanism occurring at the points with maximum displacement, as mentioned before, particularly at the top of the central column of the arcades.
Heritage 2024,73491 Heritage 2024, 7 3491 maximum displacement, as mentioned before, particularly at the top of the central column of the arcades. Figure 26. Tensile principal strains for the maximum displacements plotted in Figure 25 for each direction. 7. Conclusions This article underlines the critical importance of heritage conservation and positions HBIM as a fundamental tool to achieve this goal. It presents a comprehensive methodology for the application of HBIM in historic buildings, covering HBIM model definition, structural analysis and associated processes. This methodology is exemplified by a detailed case study, namely, the church of Santa Ana in Seville (Spain), which integrates results from historical document search, visual inspection and damage mapping, a geometric survey based on photogrammetry, material characterisation and the creation of a virtual tour with 360° views. All these sources of information are used to enrich the BIM model. The article concludes with the definition of two numerical models, each serving a specific purpose. Firstly, a highly accurate model that represents the actual dynamic behaviour of the structure under low ambient vibration is described. This model is calibrated with the data obtained from the OMA campaign, with the objective of being used for condition-monitoring purposes. The second model aims to study the seismic vulnerability of the church. For this purpose, some simplifications are made to balance reliability and computational costs. In terms of geometric data acquisition, photogrammetry proved to be a convenient and cost-effective tool, despite its limitations in capturing information from higher areas, since the implementation of a drone survey was not feasible. Nonetheless, existing drawings and traditional in situ measurements supplemented the photogrammetry data sufficiently, providing the necessary detail to define the 3D model required for the study. Upon inspection and diagnosis, some alterations in concern were identified, such as moisture stains on the intrados of the vaults, likely caused by roof infiltration and linked to the existing damage in the roof, especially cracks, which were documented during the visual inspection. Additionally, two main systems of cracks were identified: one in the lateral wall of the Epistle nave and another in the interior of the main façade. Though Figure 26. Tensile principal strains for the maximum displacements plotted in Figure 25 for each direction. 7. Conclusions This article underlines the critical importance of heritage conservation and positions HBIM as a fundamental tool to achieve this goal. It presents a comprehensive methodology for the application of HBIM in historic buildings, covering HBIM model definition, structural analysis and associated processes. This methodology is exemplified by a detailed case study, namely, the church of Santa Ana in Seville (Spain), which integrates results from historical document search, visual inspection and damage mapping, a geometric survey based on photogrammetry, material characterisation and the creation of a virtual tour with 360◦views. All these sources of information are used to enrich the BIM model. The article concludes with the definition of two numerical models, each serving a specific purpose. Firstly, a highly accurate model that represents the actual dynamic behaviour of the structure under low ambient vibration is described. This model is calibrated with the data obtained from the OMA campaign, with the objective of being used for condition-monitoring purposes. The second model aims to study the seismic vulnerability of the church. For this purpose, some simplifications are made to balance reliability and computational costs. In terms of geometric data acquisition, photogrammetry proved to be a convenient and cost-effective tool, despite its limitations in capturing information from higher areas, since the implementation of a drone survey was not feasible. Nonetheless, existing drawings and traditional in situ measurements supplemented the photogrammetry data sufficiently, providing the necessary detail to define the 3D model required for the study. Upon inspection and diagnosis, some alterations in concern were identified, such as moisture stains on the intrados of the vaults, likely caused by roof infiltration and linked to the existing damage in the roof, especially cracks, which were documented during the visual inspection. Additionally, two main systems of cracks were identified: one in the lateral wall of the Epistle nave and another in the interior of the main façade. Though minor cracks are also present, those that have been repaired and reopened are of greater concern. Consequently, it is recommended to monitor these cracks closely and investigate
Heritage 2024,73492 their causes, analysing the soil and foundation of the building as well. To address the infiltration issue, assessing the continuity in the infill and ensuring the waterproofing of the roof is advised. The creation of the HBIM model, despite requiring time and expertise due to its complexity and the volume of information to be managed, resulted in a comprehensive solution to integrate and communicate all the collected data and evidence. To enhance the methodology employed here, the deployment of a monitoring system seamlessly connected to the model is envisaged. This should comprise accelerometers for dynamic identification, tiltmeters in columns and walls with significant deviation from the vertical plane and crackmeters in main and reopened cracks. The pushover analysis allowed us to conclude that the transverse direction of the Santa Ana church is the most vulnerable one (0.12 g), and the most vulnerable elements are the vaults and the connections between the columns and the arcades. Author Contributions: Conceptualization, E.C., A.B. and N.M.; methodology, E.C., A.B. and N.M.; software, E.C.; validation, E.C., A.B. and N.M.; formal analysis, E.C.; investigation, J.A. and E.C.; data curation, E.C.; writing—original draft preparation, E.C. and A.B.; writing—review and editing, A.B. and N.M.; visualization, V.C.; supervision, N.M., V.C. and J.A.; project administration, J.A., V.C., A.B. and N.M.; funding acquisition, E.C., A.B., N.M., V.C. and J.A. All authors have read and agreed to the published version of the manuscript. Funding: This work was partly financed by FCT/MCTES through national funds (PIDDAC) under the R&D Unit Institute for Sustainability and Innovation in Structural Engineering (ISISE), under reference UIDB/04029/2020 (DOI 10.54499/UIDB/04029/2020), under the Associate Laboratory Advanced Production and Intelligent Systems ARISE under reference LA/P/0112/2020 and under the VISCO-D project of the FCT (DOI 10.54499/EXPL/ECI-EGC/0940/2021). This work was partly financed also by the FCT, under grant agreement 2020.07164.BD attributed to the first author. Data Availability Statement: The data are available on request. Conflicts of Interest: The authors declare no conflicts of interest. References 1. Lourenço, P.B. The ICOMOS Methodology for Conservation of Cultural Heritage Buildings: Concepts, Research and Application to Case Studies. In REHAB 2014—Proceedings of the International Conference on Preservation, Maintenance and Rehabilitation of Historical Buildings and Structures; Green Lines Institute: Guimaraes, Portugal, 2014; pp. 945–954. [CrossRef] 2. Lourengo, P.B.; Barontini, A.; Oliveira, D.V.; Ortega, J. Rethinking Preventive Conservation: Recent Examples. In Geotechnical Engineering for the Preservation of Monuments and Historic Sites III, Proceedings of the 3rd International Issmge TC301 Symposium, Naples, Italy, 22–24 June 2022; CRC Press: Boca Raton, FL, USA, 2022; pp. 70–86. [CrossRef] 3. ICOMOS. ICOMOS Charter. Principles for the Analysis, Conservation and Structural Restoration of Architectural Heritage; Zimbabwe. 2003. Available online: https://www.icomos.org/images/DOCUMENTS/Charters/structures_e.pdf (accessed on 3 June 2024). 4. Ramos, L.F.; Aguilar, R.; Lourenço, P.B.; Moreira, S. Dynamic Structural Health Monitoring of Saint Torcato Church. Mech. Syst. Signal Process. 2013,35, 1–15. [CrossRef] 5. Taylor, J. An Integrated Approach to Risk Assessments and Condition Surveys. J. Am. Inst. Conserv. 2005,44, 127–141. [CrossRef] 6. Panah, R.S.; Kioumarsi, M.; Lichti, D.; Maalek, S. Application of Building Information Modelling (BIM) in the Health Monitoring and Maintenance Process: A Systematic Review. Sensors 2021,21, 837. [CrossRef] [PubMed] 7. Dang, X.; Liu, W.; Hong, Q.; Wang, Y.; Chen, X. Digital Twin Applications on Cultural World Heritage Sites in China: A State-of-the-Art Overview. J. Cult. Herit. 2023,64, 228–243. [CrossRef] 8. Antonopoulou, S.; Bryan, P. Historic England 2017 BIM for Heritage: Developing a Historic Building Information Model; Historic England: Swindon, UK, 2017. 9. Martinelli, L.; Calcerano, F.; Gigliarelli, E. Methodology for an HBIM Workflow Focused on the Representation of Construction Systems of Built Heritage. J. Cult. Herit. 2022,55, 277–289. [CrossRef] 10. Godinho, M.; Machete, R.; Ponte, M.; Falcão, A.P.; Gonçalves, A.B.; Bento, R. BIM as a Resource in Heritage Management: An Application for the National Palace of Sintra, Portugal. J. Cult. Herit. 2020,43, 153–162. [CrossRef] 11. Vuoto, A.; Funari, M.F.; Lourenço, P.B. On the Use of the Digital Twin Concept for the Structural Integrity Protection of Architectural Heritage. Infrastructures 2023,8, 86. [CrossRef] 12. Castellano-Román, M.; Pinto-Puerto, F. Dimensions and Levels of Knowledge in Heritage Building Information Modelling, HBIM: The Model of the Charterhouse of Jerez (Cádiz, Spain). Digit. Appl. Archaeol. Cult. Herit. 2019,14, e00110. [CrossRef]
Heritage 2024,73493 13. Radanovic, M.; Khoshelham, K.; Fraser, C. Geometric Accuracy and Semantic Richness in Heritage BIM: A Review. Digit. Appl. Archaeol. Cult. Herit. 2020,19, e00166. [CrossRef] 14. Barontini, A.; Alarcon, C.; Sousa, H.S.; Oliveira, D.V.; Masciotta, M.G.; Azenha, M. Development and Demonstration of an HBIM Framework for the Preventive Conservation of Cultural Heritage. Int. J. Archit. Herit. 2022,16, 1451–1473. [CrossRef] 15. Brumana, R.; Della Torre, S.; Previtali, M.; Barazzetti, L.; Cantini, L.; Oreni, D.; Banfi, F.; Brumana, R.; Della Torre, S.; Previtali, M.; et al. Generative HBIM Modelling to Embody Complexity (LOD, LOG, LOA, LOI): Surveying, Preservation, Site Intervention— The Basilica Di Collemaggio (L’Aquila). Appl. Geomat. 2018,10, 545–567. [CrossRef] 16. Garcia-Gago, J.; Sánchez-Aparicio, L.J.; Soilán, M.; González-Aguilera, D. HBIM for Supporting the Diagnosis of Historical Buildings: Case Study of the Master Gate of San Francisco in Portugal. Autom. Constr. 2022,141, 104453. [CrossRef] 17. Moyano, J.; Carreño, E.; Nieto-Julián, J.E.; Gil-Arizón, I.; Bruno, S. Systematic Approach to Generate Historical Building Information Modelling (HBIM) in Architectural Restoration Project. Autom. Constr. 2022,143, 104551. [CrossRef] 18. Liu, J.; Foreman, G.; Sattineni, A.; Li, B. Integrating Stakeholders’ Priorities into Level of Development Supplemental Guidelines for HBIM Implementation. Buildings 2023,13, 530. [CrossRef] 19. Yang, X.; Grussenmeyer, P.; Koehl, M.; Macher, H.; Murtiyoso, A.; Landes, T. Review of Built Heritage Modelling: Integration of HBIM and Other Information Techniques. J. Cult. Herit. 2020,46, 350–360. [CrossRef] 20. Diara, F. HBIM Open Source: A Review. ISPRS Int. J. Geo-Inf. 2022,11, 472. [CrossRef] 21. Ewart, I.J.; Zuecco, V.; Ewart, I.J.; Zuecco, V. Heritage Building Information Modelling (HBIM): A Review of Published Case Studies. Adv. Inform. Comput. Civ. Constr. Eng. 2019, 35–41. [CrossRef] 22. Colosi, F.; Malinverni, E.S.; Leon Trujillo, F.J.; Pierdicca, R.; Orazi, R.; Di Stefano, F. Exploiting HBIM for Historical Mud Architecture: The Huaca Arco Iris in Chan Chan (Peru). Heritage 2022,5, 2062–2082. [CrossRef] 23. Crespi, P.; Franchi, A.; Ronca, P.; Giordano, N.; Scamardo, M.; Gusmeroli, G.; Schiantarelli, G. From BIM to FEM: The Analysis of an Historical Masonry Building. Build. Inf. Model. (BIM) Des. Constr. Oper. 2015,1, 581–592. [CrossRef] 24. Macwilliam, K.; Nunes, C. Structural Analysis of Historical Constructions; Springer: Berlin/Heidelberg, Germany, 2019; Volume 18, pp. 1949–1958. [CrossRef] 25. Cotella, V.A. From 3D Point Clouds to HBIM: Application of Artificial Intelligence in Cultural Heritage. Autom. Constr. 2023,152, 104936. [CrossRef] 26. Mora, R.; Sánchez-Aparicio, L.J.; Maté-González, M.Á.; García-Álvarez, J.; Sánchez-Aparicio, M.; González-Aguilera, D. An Historical Building Information Modelling Approach for the Preventive Conservation of Historical Constructions: Application to the Historical Library of Salamanca. Autom. Constr. 2021,121, 103449. [CrossRef] 27. ICOMOS. ICOMOS-ISCS: Illustrated Glossary on Stone Deterioration Patterns. 2008. Available online: https://www.icomos.org/ public/publications/monuments_and_sites/15/pdf/Monuments_and_Sites_15_ISCS_Glossary_Stone.pdf (accessed on 3 June 2024). 28. Masciotta, M.G.; Morais, M.J.; Ramos, L.F.; Oliveira, D.V.; Sánchez-Aparicio, L.J.; González-Aguilera, D. A Digital-Based Integrated Methodology for the Preventive Conservation of Cultural Heritage: The Experience of Heritage Care Project. Int. J. Archit. Herit. 2021,15, 844–863. [CrossRef] 29. Noronha Pinto de Oliveira e Sousa, M.; Correa, F.R. Towards Digital Twins for Heritage Buildings: A Workflow Proposal. Int. J. Archit. Comput. 2023,21, 712–729. [CrossRef] 30. Castelló, A. El Paso de Los Años En La Iglesia de Santa Ana: Actuaciones de Restauración, Recorrido Histórico y Reflexión; Universidad de Sevilla: Sevilla, Spain, 2016. 31. Martínez, M.d.l.A. La Iglesia de Santa Ana de Sevilla; Diputación Provincial de Sevilla: Sevilla, Spain, 1991. 32. Aguilar Valseca, J. Traza, Geometría Y Estructura De La Iglesia De Santa Ana De Sevilla. Ph.D. Thesis, Universidad de Sevilla, Seville, Spain, 2023. 33. Valseca, J.A.; Tarín, M.; Rodríguez, R.; Compán Cardiel, V.J.; Cámara, M. Geometric Approach and Structural Analysis of the Tercelete Vaults of the Captain Monte Bernardo Chapel of the Santa de Sevilla Church by Using Photogrametry Techniques and the Finite Elements Method. In REHABEND 2022. Euro-American Congress Construction Pathology, Rehabilitation Technology and Heritage Management; Universidades de Cantabria y Granada: Cantabria, Spain, 2022; pp. 282–301. 34. Gobierno de España. Norma de Costrucción Sismorresistente NCSE-02; Gobierno de España: Madrid, Spain, 2009. 35. Actualización de Mapas de Peligrosidad Sísmica de España 2012—Instituto Geográfico Nacional. Available online: https: //www.ign.es/web/libros-digitales/peligrosidad-sismica2012 (accessed on 3 June 2024). 36. Instituto Andaluz de Geofísica. Terremotos Históricos del Sur de España. Available online: http://iagpds.ugr.es/pages/ informacion_divulgacion/terremotos_historicos (accessed on 15 February 2022). 37. De Fino, M.; Galantucci, R.A.; Fatiguso, F. Condition Assessment of Heritage Buildings via Photogrammetry: A Scoping Review from the Perspective of Decision Makers. Heritage 2023,6, 7031–7066. [CrossRef] 38. Agisoft Metashape User Manual Professional Edition, Version 2.1. 2023. Available online: https://www.agisoft.com/pdf/ metashape-pro_2_1_en.pdf (accessed on 3 June 2024). 39. Cignoni, P.; Callieri, M.; Corsini, M.; Dellepiane, M.; Ganovelli, F.; Ranzuglia, G. MeshLab: An Open-Source Mesh Processing Tool. In Proceedings of the 6th Eurographics Italian Chapter Conference 2008, Salerno, Italy, 2–4 July 2008; pp. 129–136. 40. PanoramaStudio 3|PanoramaStudio Panorama Software. Available online: https://www.tshsoft.de/en/panostudio_index (accessed on 29 January 2024). 41. Pano2VR—Virtual Tour Software. Available online: https://ggnome.com/pano2vr/ (accessed on 29 January 2024).
Heritage 2024,73494 42. Borri, A.; Corradi, M.; De Maria, A.; Sisti, R. Calibration of a Visual Method for the Analysis of the Mechanical Properties of Historic Masonry. Procedia Struct. Integr. 2018,11, 418–427. [CrossRef] 43. Borri, A.; Corradi, M.; De Maria, A. The Failure of Masonry Walls by Disaggregation and the Masonry Quality Index. Heritage 2020,3, 1162–1198. [CrossRef] 44. CAPITOLO C8—COSTRUZIONI ESISTENTI—NTC Archliving. Available online: http://ntc.archliving.it/2019/02/26/capitoloc8-costruzioni-esistenti/#tabC85I (accessed on 17 June 2022). 45. Artemis Modal Pro—Structural Vibration Solutions. Available online: https://www.svibs.com/artemis-modal-pro/ (accessed on 31 January 2024). 46. Autodesk Inc. Autodesk Revit Software|BIM Software. Available online: https://www.autodesk.com/products/revit (accessed on 31 January 2024). 47. Autodesk Inc. Autodesk ReCap Pro Software. Available online: https://www.autodesk.com/products/recap (accessed on 31 January 2024). 48. DIANA. DIANA User’s Manual—Releasse 10.6. Available online: https://manuals.dianafea.com/d106/Diana.html (accessed on 3 June 2024). 49. Pachón, P.; Compán, V.; Rodríguez-Mayorga, E.; Sáez, A. Control of Structural Intervention in the Area of the Roman Theatre of Cadiz (Spain) by Using Non-Destructive Techniques. Constr. Build. Mater. 2015,101, 572–583. [CrossRef] 50. Chaves, E.; Pachón, P.; Compán, V.; Baeza, J.R. Updating of Finite Element Models through Operational Modal Analysis and Genetic Algorithms. Application to Build Architectural Heritage. In Proceedings of the 4th International Congress on Mechanical Models in Structural Engineering (CMMoST 2017), Madrid, Spain, 29 November–1 December 2017; pp. 679–695. 51. Malcata, M.; Ponte, M.; Tiberti, S.; Bento, R.; Milani, G. Failure Analysis of a Portuguese Cultural Heritage Masterpiece: Bonet Building in Sintra. Eng. Fail. Anal. 2020,115, 104636. [CrossRef] 52. Marques, R.; Lourenço, P.B. Possibilities and Comparison of Structural Component Models for the Seismic Assessment of Modern Unreinforced Masonry Buildings. Comput. Struct. 2011,89, 2079–2091. [CrossRef] Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.