Full text
Contents lists available at ScienceDirect Engineering Structures journal homepage: www.elsevier.com/locate/engstruct Evaluation of optimal sensor placement algorithms for the Structural Health Monitoring of architectural heritage. Application to the Monastery of San Jerónimo de Buenavista (Seville, Spain) Pablo Pachón a,⁎ , María Infantes b , Margarita Cámara a , Víctor Compán a , Enrique García-Macías c , Michael I. Friswell d , Rafael Castro-Triguero b a Department of Continuum Mechanics, Universidad de Sevilla, Avenida Reina Mercedes, 41012 Seville, Spain b Department of Mechanics, Universidad de Córdoba, Campus de Rabanales, 14071 Cordoba, Spain c Department of Civil and Environmental Engineering, University of Perugia, Via G Duranti 93, Perugia 06125, Italy d Zienkiewicz Centre for Computational Engineering, College of Engineering, Swansea University, Bay Campus, Fabian Way, Crymlyn Burrows, Swansea SA1 8EN, United Kingdom ARTICLE INFO Keywords: Historical building Uncertainty analysis Operational modal analysis Non-destructive test Ambient vibration test ABSTRACT In recent years, Structural Health Monitoring (SHM) based on Operational Modal Analysis (OMA) and damage detection tools has become a popular non-destructive solution to assess the real-time integrity of any kind of structure. This technique is especially well-suited for the condition-based conservation of historical structures, where minimal invasiveness must be ensured owing to their high cultural and architectural value. Optimal Sensor Placement (OSP) techniques represent a valuable tool for efficiently designing the sensor layout in a SHM system in order to achieve an effective modal identification with a reduced number of sensors and, consequently, an improved cost efficiency. In this light, this paper proposes a design methodology of sensor networks based on OSP techniques suitable for historical structures. To do so, a preliminary extensive OMA campaign is conducted in order to construct a reliable finite element (FE) model by fitting the identified modal properties. Afterwards, an optimal sensor arrangement with a limited number of sensors is obtained by applying different model-based OSP techniques. In order to improve the robustness of the solution, material uncertainties are included in the model and the optimal sensor placement is conducted within a statistical framework. This methodology is presented and evaluated with a case study of a Spanish secular building: the Monastery of San Jerónimo de Buenavista in Seville (Spain). In particular, this paper presents the results of the preliminary ambient vibration test and the modal identification of the monastery, the updating process of the FE model, as well as a critical review of the different OSP techniques within a framework of material parameter uncertainty. The presented analysis demonstrate that OSP techniques based on the rank optimization of the kinetic energy matrix of the structure yield robust sensor layout. 1. Introduction Architectural heritage in Europe consists mainly of masonry structures, such as historical bridges, castles, palaces and religious buildings. These structures are part of the national history and hold an important cultural value, as confirmed by the creation of the World Heritage List published by UNESCO. In the Spanish context, many of these still standing heritage buildings were pillaged and burned over the years, whereby their structural integrity is not always assured. The conservation and safeguarding of historical structures against material degradation and natural/human hazards represent a great concern for communities and institutions such as the International Council of Monuments and Sites (ICOMOS), which in 2003 drafted the principles for the analysis, conservation and structural restoration of architectural heritage [1]. The assessment of the health condition of historical buildings cannot usually be carried out by means of destructive tests due to the undeniable value of the historical structures. In this context, non-de- structive and non-invasive methods become a fundamental technique for this type of structures. Non Destructive Tests (NDTs) such as thermography, endoscopic tests and sonic tests can be used as complementary tools to accurately determine the characteristics of masonry https://doi.org/10.1016/j.engstruct.2019.109843 Received 12 March 2019; Received in revised form 7 September 2019; Accepted 21 October 2019 ⁎ Corresponding author. E-mail address: [email protected] (P. Pachón). Engineering Structures 202 (2020) 109843 Available online 09 November 2019 0141-0296/ © 2019 Elsevier Ltd. All rights reserved. T
elements in order to validate the structural assessment [2,3]. However, foremost among the different NDTs are OMA and model updating. These techniques allow the assessment of the structural condition through the identification and analysis of the modal properties. System identification is a research topic with decades of history, particularly in aerospace and automotive industries, where Experimental Modal Analysis (EMA) is widely used for the dynamic characterization of structural elements from input-output vibration experimental data. The implementation of this philosophy into large structures, where ambient vibration tests are easier to carry out than forced vibration tests, gave rise to output-only vibration-based system identification methods, also referred to as OMA techniques. The main objective of OMA is to identify the modal parameters (natural frequencies, vibration modes and damping ratios) through the data processing of ambient vibration records without disturbing the normal operation of the structure under study. Some basic references regarding different OMA methods and applications are [4–6]. From early approaches to now, the measurement equipment has evolved and many different algorithms have been proposed in the literature including Frequency Domain Decomposition (FDD) and Enhanced Frequency Domain Decomposition (EFDD), Fast Bayesian FFT method, Poly-Reference Least Squares Complex Frequency method (p-LSCF), Covariance-Driven Stochastic System Identification (COV-SSI), Data-Driven Stochastic System Identification (DATA-SSI), Blind Source Separation, etc. Nowadays, reliable and even automated methods are available [7], making OMA a well-established and mature technique for the structural assessment of heritage structures. The consideration of this methodology for the characterization of masonry structures is relatively recent. The PhD thesis of Ramos at the University of Minho [8] can be cited as one of the first approaches. OMA has been successfully used in [9] to identify the modal properties of a building of the Greek heritage and also in the dynamic identification of the bell tower of Trani’s Cathedral [10]. Modal updating techniques seek to minimize the mismatch between the experimentally identified modal features and the estimates of a numerical model, usually based on the Finite Element Method (FEM), through the fitting of certain modal parameters [11–14]. In the last decade, long-term vibration-based SHM is becoming increasingly popular among researchers. This non-invasive technique is mainly based on OMA techniques and makes it possible to identify structural damage over time. In reference [15], SHM technology and automated OMA techniques are specially applied to structures in seismically prone areas to evaluate the dynamic behaviour in operational conditions and the earthquake effects. Currently, there are few SHM systems installed in historical masonry structures that are faithful to the steps of the paradigm defined by Farrar and Worden [16]. Initially, most monitoring systems were implemented in bell towers, since in this type of structures the dynamic properties can be easily identified with moderate execution costs [17–19].In recent years, these techniques have been extended to other typologies of greater geometric complexity which involve structural models with larger computational demands [20,21]. In general, SHM systems aim to control the structural behaviour of these buildings to identify damage and assist decision-making for condition-based conservation management [22–24]. To facilitate the implementation of SHM systems in historical structures, OSP methods constitute a useful tool. The main goal of this technique is to efficiently design the sensor layout to achieve a correct identification of the vibrational properties with a reduced number of measurement points. The reduction of the number of sensors is a very important issue in historical structures because it implies less invasive monitoring, and minimal impact on the cultural and artistic value of the building. Furthermore, it reduces the implementation costs and the posterior data processing. The efficient design of the sensor layout is particularly relevant in geometrically complex structures for which mode shapes are also complex and involve several global and local modes within the frequency range of interest [25]. In these cases, a rational approach for the design of SHM systems can certainly take advantage of OSP techniques in order to achieve an effective modal identification. Optimal sensor placement methods have been widely employed in civil engineering structures such as bridges, whereas the number of applications in historical structures is scarce. Only a few experiences can be found in the literature [26–28]. In addition, most works on the application of OSP techniques are based upon simple benchmark case studies and/or consider deterministic definitions of the material properties of the monitored structure. In this work, four different FEM-based OSP methodologies are considered, including two approaches based on the effective independence of the target mode shapes (EFI and EFIwm), and two others based on the concept of energy matrix rank optimization (KEMRO and SEMRO). The main objective is to evaluate the performance of the different OSP methods, especially when taking into account the particular aspects involved in the numerical modelling and monitoring of historical structures. The analysis of the OSP methods is performed by considering field data and including material parameter uncertainties in the modelling. This research is carried out through a case study of the Monastery of San Jerónimo de Buenavista (Fig. 1) in Seville, Spain. First, an extensive ambient vibration test was conducted for a preliminary identification of the modal features of the structure. Afterwards, a detailed three-dimensional finite element model of the monastery is calibrated to fit the previously identified modal properties and, finally, the updated model is used to assist different OSP techniques. The effect of material parameter uncertainties is evaluated through Monte Carlo Simulations. The main novelty of this work is the evaluation of the potentials of different OSP techniques for the design of optimized sensor layout for the condition-based maintenance of historical buildings. In the first place, the use of field data from a preliminary ambient vibration test with many sensors offers a rigorous framework for the comparison of different OSP techniques and represents an advanced technique for devising cost-efficient long-term monitoring systems. Secondly, the incorporation of material parameter uncertainties in the three-dimen- sional modelling of masonry structures, and the comparison of different OSP techniques through Monte Carlo Simulations also represents a novel contribution in the field. The paper is organized as follows. Section 2presents the case study of the Monastery of San Jerónimo de Buenavista, including a detailed description of its historical background and current condition. Section 3shows the experimental structural assessment works (ambient vibration tests, OMA) and the model updating process. The optimal number of sensors for a long-term SHM system and the analysis of the four different OSP methods are addressed in Section 4, and the analysis of their robustness considering material uncertainties is presented in Section 5. Finally, the most relevant conclusions of this study are highlighted in Section 6. Fig. 1. View of the current state of the Monastery of San Jerónimo de Buenavista.. P. Pachón, et al. Engineering Structures 202 (2020) 109843 2
2. Monastery of San Jerónimo de Buenavista This study focuses on the west gallery of the main cloister of the Monastery of San Jerónimo de Buenavista, a historical building located in the city of Seville, Spain. The beginning of its construction dates back to the early fifteenth century. Originally, the Monastery of San Jerónimo consisted of an aggregate of five main buildings: the church, the eastern cloister, the main cloister, the tower and the printing press (Fig. 2a). However, only part of the main cloister and the tower of the church are still preserved today (Fig. 2b). The eastern cloister, the printing press and a large part of the church disappeared as a result of the numerous vicissitudes that the monastery has suffered over the course of centuries [29]. The remains of the main cloister constitute a Renaissance-style construction consisting of four galleries, which are made up of seven pillars on each side, attached columns and semicircular arches on the ground floor and bells on the first floor. These galleries are delimited by brick masonry walls and covered by ribbed stone vaults. Currently, in the west gallery, the entire ground floor is conserved while only the vertical structure and the arches are preserved on the upper floor (Fig. 3). In 1964, the monastery was declared a heritage site due to the architectural importance of the whole building. Since then, it has been subjected to several restoration operations [29]. The last one was the execution of a rehabilitation and adaptation project for a civic centre in 2013 (Fig. 2c). The project basically consisted of the reconstruction of the southern and eastern galleries annexed to the main cloister [30]. From a structural point of view, a mixed system of load-bearing walls and pillars supporting large-edged beams was used to construct the new building (Fig. 4). As a result of the new protection policy for the Monastery of San Jerónimo, several damages had already been detected before the construction of the new civic centre. These are related to the following aspects: cracking of structural elements, cracking in auxiliary elements, excessive deformations, failures in foundations, concentration of humidity, corrosion of metallic elements, disintegration, cracking, factory swelling and attacks, etc. (Fig. 5). In January 2015, and due to the fact that some of the damages listed above were aggravated during the works, the Town Planning Department of Seville City Council commissioned a research project for the structural analysis of the cloister. The research project indicated above follows the approach ratified by the ICOMOS 14th General Assembly in Victoria Falls, Zimbabwe, in 2003 [1]. The main objective was to conduct a diagnosis of the building to justify different conservation proposals to ensure the integrity of all its elements. A multidisciplinary work team composed of architects, engineers, archaeologists and historians carried out the research project. An extensive historical study of the different interventions in the building was finally presented, as well as a report about its structural health condition. To elaborate this report, complex numerical analysis and several moderately destructive and non-destructive tests were conducted, including ambient vibration tests, archaeological tastings, tomography and sonic wave tests and georadar tests on the columns Fig. 2. Historical development of the Monastery of San Jerónimo: (a) Original configuration, 1650; (b) historical remains, 2000; and (c) current architectural configuration of the complex, 2018. Fig. 3. Views of the west gallery of the Monastery of San Jerónimo. P. Pachón, et al. Engineering Structures 202 (2020) 109843 3
and ground. This project allowed us to obtain a vast amount of experimental and numerical information from the west gallery of the cloister. The data obtained from these previous works were fundamental for the development of the present study, since it was possible to reduce the high level of uncertainty that usually surrounds the structural characterisation of this type of buildings. 3. FE modelling and analysis The reparation works in the historical building allowed us to perform several extensive experimental campaigns in the monastery between September and November 2013. Ambient vibration tests were performed in the west gallery with the aim of identifying the natural frequencies, mode shapes and damping ratios of the system. In order to ensure an efficient identification of the modal properties of the case study, a preliminary finite element model was previously developed with the aim of properly designing the test set-up. This numerical model was later updated based on the results obtained from the OMA of the ambient vibration tests. This model updating process is described in sections below. 3.1. Preliminary FE model Based on a complex geometric survey, a sophisticated three-di- mensional FE model of the whole monastery was developed in order to conduct a subsequent structural analysis that is not a subject of this work. Initially, the modal behaviour of the entire structure was analysed. The results of the modal analysis of the monastery is depicted in Fig. 6. In the light of this analysis, the dynamic independence of each gallery was observed, since each one presents its own uncoupled vibration modes. For instance, the second and fourth global modes correspond to local modes of the west gallery. Regarding that the goal of the study is the evaluation of the different OSP techniques, it was decided to perform the analysis considering only the west gallery due to the large size of the complete model. This last consideration makes it possible to reduce the computational cost of the study without losing generality in the evaluation of the different OSP techniques for their application in masonry structures. A numerical sub-model of this gallery (Fig. 7) was generated with ANSYS [31]. The influence of the other parts of the structure were considered through appropiate boundary conditions to simulate the connection with the rest of the structure. With regard to the numerical definition of the preliminary FE model, the whole gallery was modelled with 4-node solid elements, with the exception of a 5-centimetre concrete compression layer located above the vaults which was modelled with 3-node triangular shell elements. In this way, the model has a total of 1,462,311 elements (1,454,047 solid and 8264 shell elements), 275,475 nodes and 826,425 degrees of freedom. The boundary conditions are defined as constrained displacements and free rotations in the foundation, whilst the lateral boundary conditions are extracted from the general model. Table 1 summarizes the material properties used in the modelling. Note that the repair works allowed us to reliably test some elements, such as the material properties of the fillings. Dynamic tests were also carried out on the stone and brick masonries to identify the Young’s moduli and densities of these elements. However, it was not possible to determine these parameters with certainty due to the great variability of the obtained results. Thus, these four parameters will be subsequently selected as the variables to be updated. As noted above, a modal analysis of this preliminary FE model was Fig. 4. Views of the civic centre annexed to the Monastery of San Jerónimo. Fig. 5. Detected damage in the main cloister of the Monastery of San Jerónimo. P. Pachón, et al. Engineering Structures 202 (2020) 109843 4
performed to identify which points experience larger modal displacements in as many vibration modes as possible. The first five mode shapes are shown in Fig. 8. It is observed that the complex geometric configuration of the arches on the first floor makes the dynamic features of the structure quite complex. 3.2. Ambient vibration tests An extensive ambient vibration campaign with a large number of sensors was performed on the west gallery on November 22th, 2013. Following the results obtained from the preliminary FE model, Fig. 9 shows a representation of the considered measuring points. There are two different levels, one on the first floor of the gallery ( + 6.6 m .), and the other one on the start of the upper arches ( + 12.2m ). Accelerations were registered in X and Y directions with the aim of identifying the vibration modes in the lateral and longitudinal directions of the gallery. Eight accelerometers were used placing four of them as references (blue points in Fig. 9). The other four accelerometers were moved along the columns and the walls in the two different levels. In total, the resulting number of testing set-ups was fifteen. The equipment used for these tests was composed of force balance accelerometers with a bandwidth ranging from 0.01 to 200 Hz, a dynamic range of 140 dB, a sensitivity of 10 V/g and a mass of 0.35 kg (model ES-U2). These accelerometers were connected via eight 4 0 m long cables to a twelve-channel data acquisition system with a 24-bit ADC, provided with anti-alias filters (model GRANITE). The equipment is manufactured by the company KINEMETRICS. The parameters set for the dynamic tests were a sampling frequency of 100 Hz and approximately 15 min time duration for each test. These assumptions assure that frequencies from 1 to 50 Hz would be properly measured. Excitation was always associated with environmental ambient noise, and similar conditions of temperature and humidity were considered during the tests [32]. Fig. 6. Three-dimensional FE model of the monastery and numerical identification of the first five global modes. Fig. 7. Three-dimensional FE model of the west gallery. Table 1 Material properties used in the preliminary FE model. Property Unit Value Young’s modulus of brick masonry (wall) MPa 1300 Poisson’s ratio of brick masonry –0.2 Density of brick masonry kg/m 3 1700 Young’s modulus of stone masonry (vaults and columns) MPa 1800 Poisson’s ratio of stone masonry –0.2 Density of stone masonry kg/m 3 2000 Young’s modulus of concrete slab MPa 23,000 Poisson’s ratio of concrete slab –0.2 Density of concrete slab kg/m 3 2500 Young’s modulus of filling (wall) MPa 500 Poisson’s ratio of filling (wall) –0.2 Density of filling (wall) kg/m 3 1500 Young’s modulus of filling (vaults) MPa 350 Poisson’s ratio of filling (vaults) –0.2 Density of filling (vaults) kg/m 3 900 P. Pachón, et al. Engineering Structures 202 (2020) 109843 5
3.3. OMA and model updating The data obtained in-situ were processed with the software ARTEMIS [33] using two different identification methods: Enhanced Frequency Domain Decomposition (EFDD) [34] and Stochastic Subspace Identification (SSI-UPC Merged) [35,36] (Fig. 10). Regarding the signal processing, a decimation factor of 5 and a spectral density resolution of 1024 was used, which leads to a frequency line spacing of 0.005 Hz. In this way, the mode shapes and the modal frequencies of the gallery were obtained. The resulting modal parameters of the gallery are summarized in Table 2. As indicated in Table 2, the first five vibration modes of the gallery have been identified in the frequency range from 0 to 5 Hz. Frequency values are obtained with a high degree of reliability, with differences between both methods always lower than 2% . However, the values of the damping ratios present larger variability. This typical fact indicates that higher levels of excitation are usually necessary for the correct identification of the modal damping of such structures. Time domain methods have been proved to have better performance in the identification of damping ratios under operational conditions while the EFDD method, based on computation of the response spectrum data, usually requires longer records to obtain an acceptable error in spectrum estimation and, therefore, to extract modal parameters in a reliable way [37]. Finally, in relation to the mode shapes, with the exception of the first mode, which is a bending mode of the full gallery, all the modes are induced by the changing shape of the transverse arches of the first floor. The great complexity of these modes can be seen in Fig. 11. Based on the experimental results, the preliminary numerical model is updated to simulate the current modal behaviour of the gallery and assist the evaluation of the OSP methods. The same procedure as in previous works by the authors was followed [38]. Hence, iterative methods are used to perform the FE model updating [39], introducing changes directly to some of the physical parameters that define the structure. As indicated above, the parameters to be updated are the Young’s moduli of the stone and brick masonries due to the high degree of dispersion detected during the characterization tests. The selection of more parameters is not necessary, since their values have been reliably Fig. 8. First five numerical vibration modes and undeformed configuration of the FE model. Fig. 9. Plan view of the accelerometer locations (reference accelerometers in blue). (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.) P. Pachón, et al. Engineering Structures 202 (2020) 109843 6
identified by laboratory tests. Taking into account the good quality of the experimental data, the five identified modes are selected as target modes in the updating process. Only the values of the natural frequencies are selected due to the lower reliability of the identified mode shapes in comparison with the measured natural frequencies. This fact is due to the great complexity of the mode shapes (see Fig. 11). Nevertheless, the mode shapes are later validated using the Modal Assurance Criterion (MAC) [40]: ⎜⎟ ⎜⎟⎜ ⎟ = ⎛ ⎝ ⎞ ⎠ ⎛ ⎝ ⎞ ⎠ ⎛ ⎝ ⎞ ⎠ φφ φφ φφ M AC · ·· · jk jk jjkk , T 2 TT (1) where φ j and φk are two mode shapes to be compared and the superscript T designates transposition. Therefore, considering five identified natural frequencies, the four parameters are adjusted and the residuals are minimised during the model updating. The updating process has been performed via a genetic algorithm, as implemented in Matlab [41], according to an objective function defined by the relative differences between the experimental and the numerical modal parameters. This function is usually formulated as a least-squares problem as follows: ∑∑ =−= == lθ w z θ z wr θ() 1 2[() ] 1 2() j m jNUMj EXPj j m jj 1 ,, 2 1 2 (2) where zθ() NUM j,are the values related to the physical parameters of the numerical model, θ( Ec and ρ c ), while the variables z EXP j , are the corresponding data values obtained from the experimental campaign. The differences between these variables are set as residues, rθ( ) j. Fig. 12 illustrates the convergence of the updating process using a genetic algorithm. Taking as a reference the parameters of the preliminary model, a controlled variability range is established for the updating parameters. Thus, the estimation of unrealistic solutions is avoided (Table 3). In each iteration, a population of 1000 vectors is created that, by using the rules of the genetic algorithm, minimize the objective function in Eq. (2). The calibration process finishes when the difference between the mean value (blue points, Fig. 12) and and the best value (black points, Fig. 12) of the population is less than × − 1 10 3 . Table 3 shows the considered lower and upper bounds for the updating parameters and their corresponding initial and updated values. The updated values differ by up to 20 % with respect to those defined in the initial model. Table 4 summarizes the results following the updating process and confirms the high correspondence of the results between the calibrated model and those obtained from ambient vibration tests. It can be noted that the updated frequencies are close to the experimental ones, differing by less than 5 % while exhibiting MAC values in a range from 0.82 (mode 3) to 0.98 (mode 1) for the five considered vibration modes. Fig. 10. Experimental identification by the EFDD and SSI-UPC-Merged methods. Table 2 Experimental modal parameters: natural frequencies ( f ), damping ratios ( ξ ) and standard deviation (std). Mode N o EFDD SSI f (Hz) std( f ) ξ (%) std( ξ ) f (Hz) std( f ) ξ (%) std( ξ ) 1 2.330 0.023 0.864 0.119 2.345 0.002 2.728 0.429 2 3.359 0.021 1.292 0.468 3.357 0.002 1.411 0.104 3 3.857 0.049 0.582 0.307 3.910 0.003 2.971 0.126 4 4.311 0.056 1.565 0.799 4.286 0.001 2.019 0.054 5 4.561 0.042 1.348 0.473 4.532 0.002 1.718 0.076 P. Pachón, et al. Engineering Structures 202 (2020) 109843 7
4. Sensor placement Vibration-based structural health monitoring is a suitable non-in- vasive technique for the long-term control of the condition of architectural heritage buildings. The placement of the sensors is a crucial design parameter of the monitoring system to efficiently identify the condition data. In this light, OSP techniques represent a very useful tool to design efficient monitoring set-ups, particularly in complex structures such as historical buildings. After a concise theoretical background on OSP techniques, different OSP methods are applied to the present case study: the Monastery of San Jerónimo de Buenavista. The measuring points for the OSP problem are the same as for the ambient vibration tests (see Fig. 8). The chosen set-up has 32 possible locations for the sensors, with three different measuring directions at each point: i.e. the x y , and z directions. Therefore, a total of 96 possible sensor positions are considered in the OSP problem. 4.1. Theoretical background Let us consider a monitoring system consisting of n sensors for the dynamic identification of a structural system. Let us also assume that the system consists of N degrees of freedom (DOFs) associated with the finite element mesh, and the numerical mode shapes φ j are extracted by performing modal analysis. Typically, only a limited number of DOFs and mode shapes of the FE model can be monitored due to accessibility or physical limitations (e.g. rotations or internal nodes). Therefore, considering N d candidate DOFs and N m target mode shapes, the OSP methods aim to identify the optimal positions of the n sensors among the N d available DOFs. In this work, four different FEM-based OSP methodologies are considered, including two approaches based on the Fig. 11. First five experimental vibration modes and undeformed configuration of the experimental model. Fig. 12. Convergence plot of the genetic algorithm. Blue points: Mean values of the objective function of all the population of the corresponding generation. Black points: Best values result of an individual of the population. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.) Table 3 Summary of updated parameters of the FE model computed by a genetic algorithm. Parameter Initial value Range of variation Updated value Lower Upper E b (MPa) 1300 900 1700 1000.51 ρ b (kg/m 3 ) 1700 1300 2100 1805.72 E s (MPa) 1800 1200 2200 1520.36 ρ s (kg/m 3 ) 2000 1600 2400 1954.86 Table 4 Comparison of numerical and experimental modal parameters, the latter identified by the SSI algorithm. Mode f exp (Hz) f nu m (Hz) − M ACexp num f upd (Hz) − M AC exp upd 1 2.345 2.534 ( 8 .05%)0.979 2.344 ( 0 .04% )0.980 2 3.357 3.869 ( 1 5.25% ) 0.915 3.510 ( 4 .77% ) 0.933 3 3.910 4.126 ( 5 .52% )0.819 3.873 ( 0 .94% )0.825 4 4.286 4.699 ( 9.63% ) 0.872 4.380 ( 2.19% ) 0.923 5 4.532 4.947 ( 9.15% ) 0.841 4.502 ( 0 .66% ) 0.862 [∗]The percentages in parenthesis correspond to the relative differences between frequencies. P. Pachón, et al. Engineering Structures 202 (2020) 109843 8
effective independence of the target mode shapes (EFI and EFIwm), and two others based on the concept of energy matrix rank optimization (KEMRO and SEMRO). In the following, the theoretical background of these techniques is concisely outlined. The Effective Independence (EFI) method [42,43] seeks the optimal location of sensors as those DOFs of the FE model that maximize the linear independence of the mode shapes. Based upon the modal analysis of the FE model, the target modal matrix × φ NN d m can be computed, which contains the retained target modes as columns and the candidate DOFs as rows. Thereby, the Fisher Information Matrix, × FIMNN mm ,of the target modal matrix reads [44]: =φφFIM T(3) which can be diagonalized by solving the eigenvalue/eigenvector problem: −=ψλFIM I 0 ( ) ii (4) as =− ψψFIM Λ 1 , where × Λ NN m m is the diagonal matrix of the eigenvalues λ iof the FIM , and × ψ NN mm contains the corresponding eigenvectors ψ i by columns. Given that the FIM is symmetric and positive definite, the eigenvectors are orthogonal (i.e. = − ψ ψ 1T ) and form an orthogonal basis in an N m -dimensional space. Therefore, the product φ ψ yields an × N N d m matrix that represents the projection of the mode shapes φ i onto the N m -dimensional space spanned by the vectors ψ i . Squaring each element in the φ ψ matrix as =⊗φψ φψA , with ⊗ denoting term-by-term matrix multiplication, the elements A ij of the resulting matrix represents the contribution of each i-th DOF to each j-th mode shape. If weighted by the inverse of the eigenvalue matrix of the FIM as =⊗ − φψ φψAΛ 1 , each element in this matrix has equal importance. The summation by columns of the A matrix leads to a × N1 d vector F whose components =∑= FA ij Ni j 1, mrepresent the contribution of every i-th DOF to all the retained modes of interest. Alternatively, the orthogonal projection matrix E can be defined as [42]: == −− φψ φψ φ φEΛ FIM() 1T 1T (5) The elements on the diagonal of the E projection matrix equals the components of the F vector and, therefore, represent the relative contribution of the candidate DOFs to the target mode shapes. It can be proved that the E matrix is idempotent [42], that is =E E 2. A wellknown property of idempotent matrices is that their trace is equal to their rank. Therefore, the optimal placement of sensors can be related to the DOFs where the diagonal terms of E are maximum or, in other words, the DOFs with maximum contribution to the linear independence of the target mode shapes. In this light, the EFI method is defined in an iterative way by eliminating those candidate DOFs whose contribution to the rank of the projection matrix is minimal, and the procedure finishes when the number of remaining DOFs reaches the desired number of sensors. An alternative OSP method considering the mass weighting of the effective independence of the target mode shapes is also considered, usually referred to as the EFIwm method. In this case, the Fisher information matrix FIM takes the form: =φφFIM M T (6) and, consequently, the projection matrix E reads [45]: = − φφEM FIM M() 1/2 1 T 1/2 T (7) where M stands for the numerical mass matrix extracted from the FE model. Given that the mass matrix is diagonalizable, the square roots M1/ 2 in Eq. (7) can be readily obtained by eigen-decomposition. In addition, in order to eliminate the DOFs with minimum contribution to the rank of E , Guyan reduction must be implemented at each iteration to reduce the mass matrix M to the remaining candidate DOFs. On the other hand, Energy Matrix Rank Optimization (EMRO) techniques are based upon the deployment of sensors at locations that maximize the energy of the monitored system, typically the strain energy or the kinetic energy [44]. Following the modal analysis of the FE model of the system, the strain energy ( S E ) and kinetic energy ( K E ) matrices can be written as [46,47]: ==φφ φ φ SE K KE M, TT (8) where K is the numerical stiffness matrix computed by the FEM. In this regard, the FIM matrices can be assembled by using the Cholesky decomposition of the stiffness and mass matrices as follows: ==KCC MDD, TT (9) with C and D being upper triangular matrices. Accordingly, the FIM matrices take the forms: ==φφ φ φ FIM C C FIM D D() , () SE KE TT (10) and the projection matrices: == −− φφ φ φE C FIM C E D FIM D(), () SE SE KE KE 1T1 T (11) where subscripts “SE”and “KE”relate the corresponding quantities to the strain and kinetic energies, respectively. Once the projection matrices are defined, the procedure for finding the optimal sensor localizations is identical to the previously introduced EFI algorithms. In a similar way to the EFIwm method, Guyan reduction is needed to reduce the stiffness and mass matrices at each iteration. The OSP algorithms based on the elimination of candidate DOFs with minimum contributions to the rank of EKE and ESE matrices are referred to as the KEMRO and SEMRO methods, respectively. 4.2. Identification of the optimal number of sensors The application of the above OSP techniques to the case study is now addressed. First of all, the required number of sensors is determined. Different scenarios were explored by varying the number of accelerometers of the monitoring system from 2 to 16. The EFI method is employed to find the optimal configuration for each case. In order to analyse the goodness of the OSP solution, the data of the ambient vibration tests are used. The difference between the modal properties obtained via OMA using the complete test data (reference) and those obtained only by using the data from sensors placed at the optimal configuration is analysed. In particular, the error is computed as: ∑ =⎡ ⎣ ⎢⎤ ⎦ ⎥ = R t otal error(%) i N i 1 2 1/ 2 m (12) where N m is the total number of considered modes and R i is the relative error between the reference natural frequency of mode i f;ref i ,, and the frequency identified using only data from sensors in the OSP solution; f osp i,. That is: =⎡ ⎣ ⎢− ⎤ ⎦ ⎥ R ff f (%) 100· i ref i osp i osp i ,, ,(13) In Fig. 13, the total error is shown for several cases considering different numbers of sensors in the OSP problem. Note that the error is stabilized for a number of sensors greater than 8. Given these results, it can be considered that 8 is the optimal number of accelerometers for the case of the Monastery of San Jerónimo, since a reasonable increase in the number of sensors does not significantly reduce the error in the identification of the natural frequencies of the structure. 4.3. Evaluation of the performance of OSP methods Once the required number of sensors for the long-term monitoring system has been determined, the OSP problem is performed to obtain the best positions for these 8 sensors. Four different OSP methods are evaluated, namely EFI, EFIwm, KEMRO and SEMRO. In Fig. 14, the relative error in the identification of natural frequencies and the total error are shown for each method. For the EFI and P. Pachón, et al. Engineering Structures 202 (2020) 109843 9