Full text
Evaluation of the integral methods for the kinetic study of thermally stimulated processes in polymer science L.A. PÉREZ-MAQUEDA*, P.E. SÁNCHEZ-JIMÉNEZ AND J.M. CRIADO Instituto de Ciencia de Materiales de Sevilla. C.S.I.C.-Universidad de Sevilla. Avd. Americo Vespucio 41092 Sevilla. Spain *Corresponding author. E-mail address: m[email protected]
2 Abstract This paper reports on the accuracy of the integral methods used for the kinetic analysis of degradation and crystallization of polymers. Integral methods are preferred by many authors over the differential ones because often the experimental data obtained, such as thermal degradation studied by thermogravimetry, are integral and the differentiation of the integral data usually produces an unwilling increase of the noise. A problem of the integral methods is the fact that Arrhenius integral function does not have an exact analytical solution. Thus, several approximated equations have been proposed in literature. Some of these approximations lead to a linear relation between the logarithm of g(α) and a predetermined function of T, in such a way that the activation energy can be determined from the slope of the plot of ln g(α) versus the predetermined T function. The most popular approximations to the Arrhenius integral in polymer science are those of Van Krevelen et al, Horowitz and Metzger, and Coats and Redfern. Although these three approaches where proposed fifty years ago, they are extensively used nowadays and several hundreds of citations to the original papers can be found in recent polymer science publications. Despite their popularity, there are cast doubts on the accuracy of these approximations, because they provide significant deviations in the determination of the actual values of the Arrhenius integral when used for simulating α-T plots. Nevertheless, a comprehensive study of the systematic errors in the activation energy calculated from these integral methods is still missing. In this paper a comparative study of the accuracy of the different integral methods is performed. The calculated errors are tested with simulated and experimental results. Keywords: Kinetics; Activation Energy; Thermal Properties; Teflon
3 1. INTRODUCTION Studies of thermal degradation of polymers are a matter of major interest for determining the thermal stability of the polymers. Thermogravimetry (TG) has been extensively used for such studies. Experiments are usually performed under linear heating rate program. Under these conditions, the temperature varies in a wide range of values and the thermal behaviour of the sample can be recorded in a single experiment. In the TG experiment, the recorded magnitude, i.e. mass, is proportional to the extent of the reaction ( ). The TG data can be used for obtaining the kinetic parameters of the thermal degradation of the polymer sample. To perform the kinetic study of the integral curve (mass loss versus temperature) directly obtained from thermogravimetric analysis, it is necessary to use an integral analysis method. A limitation of the integral methods of kinetic analysis is that the temperature integral does not have an exact analytical solution for linear heating rate program [1]. In literature, different approaches have been reported for this integral, such as rational approximations that allow accuracies better than 10-8% in the estimation of the temperature integral [2]. Other approximations to the temperature integral lead to linear correlations between the logarithm of the integral function describing the mechanism of the process and a function of temperature, in such a way that the activation energy is obtained from the slope. Among these latter approximations, the most commonly used in studies of thermal degradation of polymers (see for example references [3-6] for some recent papers) are those of Van Krevelen et al. [7], Horowitz and Metzger [8], and Coats and Redfern [9, 10]. In fact, for the original papers of Coats and Redfern [9, 10], Horowitz and Metzger [8], and Van Krevelen et al. [7] we have found about 400 citations in polymer papers published only in the last five years (from 1999 to nowadays, this information was obtained from ISI
4 Web of Science data base). Nevertheless, there are still some doubts about their accuracy for determining the kinetic parameters [1, 11-14] because their lack of accuracy in the estimation of the temperature integral. However, the most common application of these approximations is the determination of the activation energy and not the computation of the temperature integral. In this paper we intend to perform a comparative study of the accuracy of such approximation to the temperature integral for the determination of the activation energy. The calculated errors are checked with simulated and experimental curves.
5 2. THEORY The general equation that describes the reaction rate for the thermal degradation of polymers can be written as follows: )( / feA dt dRTE (1) that after taking logarithms can be rearranged in the following form RT E A f dtd ln )( )/( ln (2), where t is the reaction time, is the extent of reaction, A the preexponential factor of Arrhenius, E the activation energy, R the gas constant, and f( ) is a function depending on the reaction mechanism. Eqn. 1 is a constitutive equation that must be accomplished whatever would be the thermal pathway used for achieving a particular value of T- α- dα/dt [15-18].Thus, the activation energy of a degradation reaction recorded under linear heating rate would be obtained from the plot of the left hand side of Eq. (2) as a function of 1/T. Eq. (1) cannot be directly integrated under rising temperature conditions unless the the temperature were a known function of the time. If the degradation of polymers is recorded under a linear heating rate β = dT/dt, Eq. (1) would also be written in the form )( / fe A dT dRTE (2). The integration of Eq. (2) leads to dTe A f d g T RT E 00 )( )( (3a), or I A g )( (3b),
6 where I stands for the integral of the Arrhenius equation. Eqs. (3a) and (3b) allow the direct analysis of the experimental data obtained from the measurement of the evolution of an integral magnitude, such as the mass loss recorded in a thermobalance as a function of the temperature under a linear heating program. The integral of the Arrhenius equation does not have an exact solution and therefore this expression cannot be expressed in a closed form. Several approaches have been proposed in literature for the integral of the Arrhenius equation in order to determine the activation energy from experimental integer data. As it was mentioned above, in polymer science, the most commonly used approaches are those of Van Krevelen et al [7], Horowitz and Metzger [8], and Coats and Redfern [9, 10]; the corresponding approximated Arrhenius integral functions, Ia, are included in Table 1. The use of these approximations implies using the following equation: a I A g )( (4), instead of the exact Eq. (3b) for calculating the activation energy. In general, the approximations to the temperature integral have been chosen in such a way that the plot of the logarithm of the corresponding g( ) function versus a function of temperature (f(T)) lead to a straight line from whose slope is determined the activation energy: )( )( ))(ln( a Ef Tdf gd (5) The corresponding f(T) and f(Ea) functions listed in Table 1 depend on the considered approximation to the Arrhenius integral and the subindex a stands for approximated. The relative error ε of the activation energy (Ea) calculated by the different approximated equations can be defined by the following equation:
7 1001100% E E E EE aa (6) By differentiating Eq. (3b) with regards to f(T) we get )( ln )( )(ln Tdf Id Tdf gd (7) By combining eq. (5) and (7) results )( )( ln a Ef Tdf Id (8). By introducing the variable x = E/RT, it is shown that the derivative of f(T) is connected with the derivative of x through the expression: dxTTf E R Tdf 2 ).(')( (9). Thus, from Eqs. (8) and (9), we get )()(' ln 2 a EfTfT E R dx Id (10) The value of Ea/E as a function of x and dxId /ln can be directly obtained from Eq. (10) after the substitution of the f(Ea) and f’(T) corresponding to the different approximated equations tabulated in Table 1. Finally, after substituting the expressions for Ea/E into Eq. (6), the errors functions included in Table 2 were obtained for the Van Krevelen et al [7], Horowitz and Metzger [8] and Coats and Redfern,[9, 10] approaches, respectively. The error expressions shown in Table 2 indicate that the errors in the activation energy depend on the values of x=E/RT for the three approximated equations here analysed. The values of % tabulated in Table 3 for the different approaches have been calculated as a function of E/RT after calculating the corresponding values of dxId /ln
8 by numerical methods using the MathCad software with a tolerance better than 10-9. It is clear from this table than the errors significantly change as a function of x. Thus, the larger the value of x, the smaller the error; in the limit, for x= , the error is zero. The approximation of Coats and Redfern is the one that leads to the smallest errors in the determination of the activation energy, followed by that of Van Krevelen et al., while that of Horowitz and Metzger is the lest accurate one in terms of determining activation energies. 3. EXPERIMENTAL A commercial polytetrafluoroethylene (Teflon) sample supplied by Aldrich was used. Thermogravimetric experiments were performed under linear heating rate conditions ( =5 K min-1) and flow of helium (100 cm3 min-1) in a Stanton Redcroft TG-770 thermobalance. 4. CHECK OF THE ERRORS WITH SYMULATED AND EXPERIMENTAL CURVES To check the values of the errors tabulated in Table 3, a set of two curves (Fig. 1) have been simulated for linear heating rate conditions (heating rate = 10 K min-1), F1 kinetic model and the kinetic parameters included in the figure caption. The simulations have been performed by solving eq. (1) by the Runge-Kutta method using the Mathcad software and a tolerance (precision in the calculus) of 10-9 The values of the activation energies (Ea) and errors (ε%) obtained of the analysis of the simulated curves included in Figs 1a and 1b by means of the different integral methods are included in Table 4. The resulting values of ε% are consistent with those tabulated in Table 3. The small deviations observed are due to the fact that the errors tabulated in
9 Table 3 have been calculated for determined values of x, while for the simulated curves T varies during the experiment and the values of x are not constant along the entire simulated curve. On the other hand, it is noteworthy to point out that the activation energies obtained from the Van Krevelen et al. and Horowitz and Metzger methods would be very sensitive to the selected reference temperature. Figure 2 shows the thermal decomposition of the Teflon sample under linear heating rate conditions. This curve has been analyzed by means of the differential and integral methods by assuming an F1 kinetic model. For the integral analysis, the three different approaches analyzed here have been used. Table 5 includes the resulting values of the activation energy, correlation coefficient and errors in the activation energy, as calculated by assuming the value of E obtained from the differential method as the correct one because no approximation is used for deriving Eqns. (1) and (2). Using the kinetic parameter obtained of the differential method, the Teflon decomposition curve has been reconstructed (line in Fig 2). The agreement between the experimental (circles) and simulated (line) curve in Fig. 2 is excellent. For the different kinetic analysis methods included in Table 5, the correlation coefficients are very high, while the values of the corresponding activation energy slightly differ. The errors in the values of Ea are consistent with those expected for a value of x 40 and tabulated in Table 3. Although it is not common to find in literature papers where the thermal degradation of polymers is analyzed simultaneously by the different integral equations analyzed here, we have found some recent papers published in Polymer where the same experimental results are systematically analyzed by a series of different integral method. Thus, in the paper by Nuñez et al. [3], the authors report on the decomposition of the epoxy system BADGE(n=0)/1,2 DCH, and perform an exhaustive kinetic analysis
16 Figure Captions Fig. 1. Simulated curves under linear heating rate conditions (β= 10 K min-1), F1 kinetic model: (a) E=20 kJ mol-1 and A=12 min-1; and (b) E=100 kJ mol-1 and A=108 min-1 Fig.2. Experimental curve () for the thermal decomposition of Teflon under linear heating rate conditions ( =5 K min-1) and flow of helium (100 cm3 min-1). The solid line represents the curve simulated for an F1 kinetic model and the activation energy obtained from the analysis of the experimental curve by means of the differential method (Table 5).
17 200 300 400 500 600 700 0.0 0.2 0.4 0.6 0.8 1.0 T / K ab Fig. 1
18 700 750 800 850 900 950 0.0 0.2 0.4 0.6 0.8 1.0 T / K Fig. 2.