A Comparison of Objective and Subjective Sleep Quality Measurement in a Group of Elderly Persons in a Home Environment

Gaiduk, Maksym; Seepold, Ralf; Martínez Madrid, Natividad; Ortega Ramírez, Juan Antonio; Conti, Massimo; Orcioni, Simone; Penzel, Thomas; Scherz, Wilhelm Daniel; Perea, Juan José; Serrano Alarcón, Ángel; Weiss, Gerald

Abstract

The main aim of presented in this manuscript research is to compare the results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress devicewas used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjective sleep quality level. The achieved results confirm the correlation between objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points.

Full text

A Comparison of Objective and Subjective Sleep Quality Measurement in a Group of Elderly Persons in a Home Environment Maksym Gaiduk1,2(B), Ralf Seepold1,3, Natividad Martínez Madrid3,4, Juan Antonio Ortega2, Massimo Conti5, Simone Orcioni5, Thomas Penzel6,7, Wilhelm Daniel Scherz1,2, Juan José Perea3, Ángel Serrano Alarcón4, and Gerald Weiss8 1HTWG Konstanz, Alfred-Wachtel-Str. 8, 78462 Konstanz, Germany {maksym.gaiduk,ralf.seepold,wscherz}@htwg-konstanz.de 2University of Seville, Avda. Reina Mercedes s/n, Seville, Spain [email protected] 3I.M. Sechenov First Moscow State Medical University, Moscow, Russian Federation [email protected] 4Reutlingen University, Alteburgstr. 150, 72762 Reutlingen, Germany {natividad.martinez, angel.serrano_alarcon}@reutlingen-university.de 5Università Politecnica delle Marche, via brecce bianche 12, 60131 Ancona, Italy {m.conti,s.orcioni}@univpm.it 6Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany [email protected] 7Saratov State University, Saratov, Russian Federation 8AWO Kreisverband Schwarzwald-Baar e.V., Klinikstraße 3, 78052 Villingen-Schwenningen, Germany [email protected] Abstract. Themainaimofpresentedinthismanuscriptresearchistocomparethe results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress device was used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjectivesleepqualitylevel. The achievedresultsconfirmthecorrelationbetween objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points. 1 Introduction Sleep is an essential part of our life. It is necessary for the restoring of our physical and mental health [1]. However, it is essential to consider that sleep duration alone is not enough for the complete recuperation of our body and brain – sleep quality is another significant factor [2]. Measurement of sleep quality can be, in general, separated into two main classes: •Objective – with the help of devices, which collect bio-vital data. •Subjective – the information is reported using questionnaires [3]. Both mentioned above groups of measurement approaches have different methods. For example, polysomnography or actigraphy can be used for objective measurement. Using a sleep diary or a PSQI questionnaire may provide the data for the subjective measure of sleep quality. However, of course, also other approaches are existing and being described in several scientific publications [4–6]. The primary motivation in this manuscript research is to compare the objective and subjective measurement of sleep quality. To understand the tendency, if persons are more likely to under- or overestimate the quality of their sleep and to check if it is possible to avoid subjective measuring in case of long-term use of technologies for objective measurement. 2 State of the Art Sleepquality,ingeneral,amongtheelderly,ismainlyatopicofalotofscientificresearch. In the following, only a small selection of relevant approaches are presented. General information about the measurement of sleep quality and the comparison of different approaches is a central topic of [4]. It combines the description of different methods of measurement and challenges of sleep quality determination. Investigation of age-related differences in self-reported sleep quality in correlation with health outcomes is presented in [1]. The conclusion was reached that there is a correlation between better self-reported sleep and better health outcomes, especially for mental health. Furthermore, a decrease in sleep quality across the lifetime was reported, particularly about sleep efficiency. In [6], the comparison of subjective and objective sleep analysis, including measurement of sleep quality, is done. The total amount of 17 persons (14 females and three males) has participated in this study. The correlation between objective and subjective determination of sleep quality was reported, though it was small (r =0.270, p <0.01). Another study on the comparison of subjective and objective measurement of sleep quality, but with a focus on the age group 55+, is presented in [5]. As a result, there is a significant difference between these two types of measurement, at least for the mentioned above age group. The final recommendation was made to use both subjective and objective methods of measurement to get a complete conclusion on sleep quality. Another system for the recognition of Sleep/Wake states, which can be used to calculate sleep quality, is presented in [7]. It is essential to measure the sleep quality in the older adults’ group but also to understand what can affect it. This topic was discussed in [8], where the correlation between subjectively measured sleep quality and physical activity was determined. This result confirms that subjective measurement of sleep quality can be correlated with the lifestyle. 3 Methodology Our study was running over two weeks with ten subjects; the group consisted of elderly persons (65+). Each participant was in his private home to maintain a routine environment. On the first day, the necessary devices were installed and explained. Additionally, the questionnaires have been taught. On the last day, the devices were picked up, and the final survey was filled out with the participant. During the study, a technical solution for sleep monitoring (EmFit [9]) was provided for each participant, which should be used over the test period. This device is based on ballistocardiography principle, it is contactfree, autonomous, automatic and can be placed under a bed mattress. This allowed sleep quality to be measured objectively during the two weeks. The used device can measure heart rate [10], heart rate variability [11], monitor breathing and sleep (incl. Sleep staging) [12]. Besides, two short daily questionnaires (including sleep diary and a general question of perceived sleep quality), there was a more detailed sleep questionnaire (PSQI) at the end of the two weeks. For the subjective documentation of the sleep quality, a graphical representation of this question was used (see Fig. 1), here, the participant tagged the perceived sleep quality for the last night. For the evaluation, a scale was graduated in 10 sections, so that we could get a value between 1 to 10. Fig. 1. Graphical representation of the sleep quality question As mentioned above, the EmFit device was used for the objective measurement of sleep quality (sleep score). This device calculates the value of sleep quality according to following Formula 1[6]: SleepScore = (total_duration_of_sleep + (duration_of_REM_sleep * 0.5)+ (duration_of_DEEP_sleep * 1.5))− 8.5∗0.5∗sleep_class_awake_duration 3600 +number_of_wakenings 15 (1) The maximal value of this objective measurement is 100 points. For the evaluation, we have divided this number by 10 leaving one position after the decimal point to get the same range of values as by subjective measurement. Ethicalofficers of HTWG Konstanzand the Universityof Applied SciencesKempten approved the experiment design. After the study’s execution, the objective and the subjective measurements were collected and evaluated. The total amount of 140 nights was recorded. Due to missing data from a used technical device or not filled out questionnaires on some days, finally, only the records of 73 nights are available for the evaluation. Its outcome is presented in the section ‘Results’. 4 Results All sleep quality data collected with the objective (sleep tracking device) and subjective (questionnaire) approach were used for the evaluation. As mentioned before, some night records were excluded from the evaluation due to missing parts. Table 1represents the calculated statistical values of differences in an objective and subjective measurement (’subjective measurement - objective measurement’) for each subject, where negative numbers of median and mean that these values represent the case that subjects underestimate the quality of sleep. It is recognizable that 8 of 10 subjects (highlighted light red in the table) have a feeling that their sleep was of less quality than a sleep tracking device measured it. For 8 out of 10 subjects, the value of the standard deviation is low and stays in range between 1.2 and 2.1; the average standard deviation is equal to 2. According to the ’68-95-99,7 rule’ [13], 68% of all values will not differ more than by ±2, and 95% of all values will not differ more than by ±4 means that there is a strong correlation between objective and subjective measurement. Table 1. Statistical values of sleep quality subjective-objective measurement. Subject 1 Subject 2 Subject 3 Subject 4 Subject 5 Subject 6 Subject 7 Subject 8 Subject 9 Subject 10 Median -1,8 -2,3 -5,3 2,5 -1,0 -1,6 -0,5 -1,8 -3,9 0,8 Mean -1,5 -1,5 -4,2 2,8 -1,3 -1,4 -1,3 -1,9 -3,2 0,8 Standard deviaƟon 2,1 2,0 2,5 1,2 1,6 1,5 2,0 1,8 3,2 1,9 Variance 4,6 3,9 6,2 1,4 2,6 2,1 4,0 3,1 10,2 3,5 The graphical representation of calculated values in Fig. 2represents the stable value of standard deviation for all subjects. Although the calculated statistical values for most of the subjects are similar, there is some outlier, which could be partially explained by not complete night records for all the days. It means if, from 14-night records for some of the subjects, only seven or less are complete (subjective and objective measurements are available). These records have a high variance. The average variance value will also be high, whereas, with all 14 complete records, it could be lower, because the outliers would be less significant with the higher amount of analyzed data. This is one of the reasons why in future research, the focus will be done on getting a higher amount of complete records to decrease the influence of outliers. Fig. 2. Median, standard deviation, variance, and mean values 5 Conclusion As presented in this manuscript, research has confirmed a strong correlation between subjective and objective measurement of sleep quality. This knowledge is important for assessingpossiblesubstitutionof subjectivemeasureusingonlytheinformation obtained with devices collecting bio-vital data (objective measurement). This substitution could be necessary for the development of AAL-Systems with sleep quality measurement as one of its parts. Our group is planning to develop a prototype of an AAL-System for the home environment with several devices working in the area of health monitoring. The results described in this document study are providing necessary information for this future development. Furthermore, a new study with a higher number of participants of the same age group is currently planning. Acknowledgments. This research was partially funded by the EU Interreg V-Program “Alpenrhein-Bodensee-Hochrhein”: Project “IBH Living Lab Active and Assisted Living”, grants ABH040, ABH041 and ABH066. Thomas Penzel has been partially funded by RF Government grant Nº 075-15-2019-1885. We also thank the caregivers of the Workers’ Welfare Association (AWO) Schwarzwald-Baar e.V. for their contribution in conducting the study. References 1. Gadie, A., Shafto, M., Leng, Y. et al.: How are age-related differences in sleep quality associated with health outcomes? An epidemiological investigation in a UK cohort of 2406 adults. BMJ Open (2017) 2. National Heart Lung and Blood Institute (NHLBI): Your Guide to Healthy Sleep, NIH Publication No. 11–5271. National Heart, Lung, and Blood Institute, Bethesda (2011) 3. Unruh, M.L., Redline, S., An, M.-W., Buysse, D.J., Nieto, F.J., Yeh, J.-L., Newman, A.B.: Subjective and objective sleep quality and aging in the sleep heart health study. J. Am. Geriatr. Soc. 56, 1218–1227 (2008). https://doi.org/10.1111/j.1532-5415.2008.01755.x 4. Krystal, A.D., Edinger, J.D.: Measuring sleep quality. Sleep Med. 9(Supplement 1), 10–17 (2008). ISSN 1389-9457 5. Landry, G.J., Best, J.R., Liu-Ambrose, T.: Measuring sleep quality in older adults: a comparison using subjective and objective methods. Front. Aging Neurosci. 7, 166 (2015) 6. Merilahti, J., Saarinen, A., Päkkä, J., Antila, K., Mattila, E., Korhonen, I.: Long-term subjective and objective sleep analysis of total sleep time and sleep quality in real life settings. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS, Cité Internationale, Lyon, France (2007) 7. Gaiduk, M., Seepold, R., Penzel, T., Ortega, J.A., Glos, M., Martínez Madrid, N.: Recognition of sleep/wake states analyzing heart rate, breathing and movement signals. In: 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2019, pp. 5712–5715 (2019). doi: https://doi.org/10.1109/EMBC.2019.8857596 8. Štefan, L., Vrgoˇc, G., Rupˇci´c, T., Sporiš, G., Sekuli´c, D.: Sleep duration and sleep quality are associated with physical activity in elderly people living in nursing homes. Int. J. Environ. Res. Public Health 15(11), 2512 (2018) 9. Kortelainen, J.M., van Gils, M., Päkkä, J.: Multichannel bed pressure sensor for sleep monitoring. Comput. Cardiol. 39, 313–316 (2012) 10. Brüser, C., Kortelainen, J.M., Winter, S., Tenhunen, M., Pääkkää, J., Leonhardt, S.: Improvement of force-sensor-based heart rate estimation using multi-channel data fusion. IEEE J. Biomed. Health Inform. 19(1), 227–235 (2014) 11. Tenhunen, M., Hyttinen, J., Lipponen, J.A., Virkkala, J., Kuusimäki, S., Tarvainen, M.P., Karjalainen, P.A., Himanen, S.L.: Heart rate variability evaluation of Emfit sleep mattress breathingcategoriesinNREMsleep.Clin.Neurophysiol.(2014).pii: S1388–2457(14)00468– 4 12. Kortelainen, J.M., Mendez, M.O., Bianchi, A.M., Matteucci, M., Cerutti, S.: Sleep staging based on signals acquired through bed sensor. IEEE Trans. Inf. Technol. Biomed. 14(3), 776–785 (2010) 13. Pukelsheim, F.: The three sigma rule. Am. Stat. 48(2), 88–91 (1994). https://doi.org/10.2307/ 2684253