scieee AI-readable full text Open interactive document viewer

Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study

Corcuera Flores, José Ramón; Pérez Fierro, Manuel Luis; Blanco Carrión, Andrés; Torres-Lagares, Daniel; Castellanos Cosano, Lizett; Machuca-Portillo, Guillermo

Abstract

Background: The objectives were to evaluate the bone loss (BL) around narrow diameter implants (3.3 mm) 2 years after implant loading and compare with the bone loss around conventional-diameter implants (4.1 mm), as well as with clinical and anatomical variables. 2-years follow-up. Material and Methods: Cases: 20 patients either gender-age, narrow implants (Straumann TM-SLA, diameter 3.3 mm); Control: 20 patients matching for gender-age, conventional implants (Straumann TM-SLA, diameter 4.1). Total 82 implants (31 narrow implants and 51 conventional implants) in 40 patients. To avoid statistical bias, a cluster of one implant per patient was randomly selected (20 narrow implants and 20 conventional implants). To evaluate changes resulting from bone loss around the implants, a total of 80 panoramic radiographs were taken of all 40 patients; the first panoramic image was taken at the time of implant loading and the second one 2 years later. Clinical and demographic variables were obtained from the patients’ medical records. Statistical method: Spearman’s correlation coefficient, chi-squared (Haberman’s post hoc), Mann-Whitney U and Kruskal-Wallis tests. Statistical significance p < 0.05. Results: No significant differences in bone loss around were found around narrow implants versus conventional implants. Differences linked to tobacco use were found after studying one implant per patient (p < 0.05). Conclusions: With the limitations of the present study, no significant differences in BL were found when comparing narrow implants with conventional implants after 2 years of implant loading. There were also no differences found when accounting for other demographic and clinical variables, with the exception of tobacco use.

Full text

J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e79 Journal section: Prosthetic Dentistry Publication Types: Research Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study José-Ramón Corcuera-Flores 1, Manuel Pérez-Fierro 2, Andrés Blanco-Carrión 3, Daniel Torres-Lagares 4, Lizett Castellanos-Cosano 5, Guillermo Machuca-Portillo 6 1 PhD, DDS, Associate Professor, Master’s Program of Special Care in Dentistry, School of Dentistry, University of Seville, Spain 2 DDS, Associate Professor, Master’s Program of Oral Surgery, School of Dentistry, University of Seville, Spain 3 PhD, MD, DDS, Full Professor and Chairman, Oral Medicine, School of Dentistry, University of Santiago de Compostela, Spain 4 PhD, DDS, Full Professor, Oral Surgery, School of Dentistry, University of Seville, Spain 5 PhD, DDS, Associate Professor, Oral Surgery, School of Dentistry, University of Seville, Spain 6 PhD, MD, DDS, Full Professor and Chairman, Special Care in Dentistry, School of Dentistry, University of Seville, Spain Correspondence: University of Seville School of Dentistry C/Avicena s/n 41009 Seville, Spain [email protected] Received: 10/10/2019 Accepted: 25/11/2019 Abstract Background: The objectives were to evaluate the bone loss (BL) around narrow diameter implants (3.3 mm) 2 years after implant loading and compare with the bone loss around conventional-diameter implants (4.1 mm), as well as with clinical and anatomical variables. 2-years follow-up. Material and Methods: Cases: 20 patients either gender-age, narrow implants (Straumann TM-SLA, diameter 3.3 mm); Control: 20 patients matching for gender-age, conventional implants (Straumann TM-SLA, diameter 4.1). Total 82 implants (31 narrow implants and 51 conventional implants) in 40 patients. To avoid statistical bias, a cluster of one implant per patient was randomly selected (20 narrow implants and 20 conventional implants). To evaluate changes resulting from bone loss around the implants, a total of 80 panoramic radiographs were taken of all 40 patients; the first panoramic image was taken at the time of implant loading and the second one 2 years later. Clinical and demographic variables were obtained from the patients’ medical records. Statistical method: Spearman’s correlation coefficient, chi-squared (Haberman’s post hoc), Mann-Whitney U and Kruskal-Wallis tests. Statistical significance p < 0.05. Results: No significant differences in bone loss around were found around narrow implants versus conventional implants. Differences linked to tobacco use were found after studying one implant per patient (p < 0.05). Conclusions: With the limitations of the present study, no significant differences in BL were found when comparing narrow implants with conventional implants after 2 years of implant loading. There were also no differences found when accounting for other demographic and clinical variables, with the exception of tobacco use. Key words: Lagervall & Jansson’s index, bone loss, narrow implants, panoramic radiographs. doi:10.4317/jced.56422 https://doi.org/10.4317/jced.56422 Article Number: 56422 http://www.medicinaoral.com/odo/indice.htm © Medicina Oral S. L. C.I.F. B 96689336 - eISSN: 1989-5488 eMail: [email protected] Indexed in: Pubmed Pubmed Central® (PMC) Scopus DOI® System Corcuera-Flores JR, Pérez-Fierro M, Blanco-Carrión A, Torres-Lagares D, Castellanos-Cosano L, Machuca-Portillo G. Bone loss around narrow implants versus standard diameter implants: Retrospective 2-years case-control study. J Clin Exp Dent. 2020;12(1):e79-84. http://www.medicinaoral.com/odo/volumenes/v12i1/jcedv12i1p79.pdf J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e80 Introduction Dental implants have always undergone different modifications in order to adapt them as much as possible to the morphology of the bone where they will be placed (1). In this regard, it is important to reduce the diameter of implants placed in areas with limited space for prosthetic reconstruction, such as between adjacent crowns, as conventional-diameter implants may cause damage to the periodontal ligament of adjacent teeth o compromising aesthetics (2-4). Narrow implants (those with a diameter less than 3.4 mm) (5) are particularly useful when the bone crest width does not allow for placement of a conventional diameter implant without the use of regeneration techniques (6-8). There is currently no clear scientific evidence regarding the success rate of narrow implants (9-11). This study’s main purpose is to evaluate the bone loss (BL) around narrow implants after 2 years of implant loading and compare it to that of conventional¬ diameter implants. BL were also evaluated by taking into account where implants were placed, type of loading, whether implants were placed in areas that had previously undergone bone regeneration, or whether patients had previously suffered from periodontal disease. Material and Methods -A retrospective case-control study was carried out. 82 implants (31 narrow implants and 51 conventional implants) placed in 40 patients were selected. To avoid statistical bias, a cluster of one implant per patient was randomly selected (20 narrow implants and 20 conventional implants). Randomization was carried out by numbering the implants present in the patient and rolling a die to identify the selected implant. The group “Cases” described as patients of either gender or age, carriers exclusively narrow implants (StraumannTM, grade 4 titanium, SLA surface, 3.3 millimeters in diameter, length 10-12 mm, Switzerland) and having a minimum 2 years of followup. 20 patients with these characteristics were found from 2009 until 2014. The group “Control”, sought by matching for gender and age other 20 patients, who will carry only standard implants of the same brand, with identical lengths and identical tracking system but with 4.1 millimeters in diameter. To evaluate the changes resulting from BL around the implants, a total of 80 panoramic radiographs were used of the 40 patients. The first panoramic image of each patient was taken when the implants were loaded and the second one 2 years after implant placement, using a Planmeca ProMax® orthopantomograph, serial number RDX309857, with a magnification of 1-1. The patients’ head and lip position in the orthopantomograph was controlled when taking the radiographs. All BL measurements were taken by a calibrated examiner. This calibration consisted in having a second examiner retake all measurements and compare them. The evaluator calculated a correlation coefficient of 0.925, which implies a coincidence percentage higher than 90%. -Inclusion and exclusion criteria: The patients included in this study had implants (3.3 or 4.1 mm) placed in either the anterior or posterior region of the mandible and maxilla. The patients excluded in this study were treated with 8-mm or smaller implants, whose implants were loaded for less than 2 years, with more than two years of follow-up but no radiography at 2 years (the initial total number of patients with narrow implants was 22, but the final number of patients studied is 20), patients taking medication that affects bone metabolism (corticosteroids, bisphosphonates), patients with inflammatory bone diseases or genetic diseases, patients with active periodontal disease (must be under control after 6 months of periodontal treatment). No early failures were recorded before two years. -Studied variables: In the present study, BL (main variable) was measured (each implant was assigned to a category) using Lagervall & Jansson’s index (12) modified by Corcuera Flores et al. (8) to add a fifth category, using panoramic radiographs of each patient to compare the panoramic images taken after implant loading with the ones taken two years later. The implants used in this study were loaded with single crowns, fixed implant-borne prostheses that require splinting with other implants or overdentures. The variables tobacco smoking, age and gender were collected from the medical records of patients enrolled in the study. Periodontitis was pre-diagnosed when patients exhibited insertion loss and/or a probing depth of 4 mm or more and bleeding on probing (13). An osteoconductive biomaterial (cancellous bone) and equine collagen membranes (Bio- Gen® and Bio-Teck®, BIOTECK S.p.A., Arcugnano VI Italy) were used when bone grafting was necessary. If this type of bone graft was used, it was noted in the patient’s medical record. -Statistical study: All statistical procedures were carried out using SPSS 19.0 for Windows (IBM, USA). Frequency and percentage were used to describe qualitative variables. The correlation coefficient was measured using the Spearman test. Qualitative data were compared using the Chi-squared test and applying Haberman’s post hoc test. Quantitative ordinal data (BL) were compared using the Mann-Whitney U test if the independent variable had 2 categories, and the Kruskal-Wallis test was used if the independent variable had more than 2 categories. The statistical significance can be found in the tables, while the normal ranges are displayed in the text. Regarding the power of the study, this requires an expec- J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e81 ted difference between groups who was estimated at 0.6 points in relation to the primary endpoint (BL). Under these conditions and considering a margin of error of 5% alpha, the power of the test is higher than 78% (less than 22% beta error). The statistical significance was p < 0.05. Results The study’s sample consisted of 40 patients (23 women and 17 men) with an average age of 66.97 years (range 58-72). A total of 82 implants were placed in these patients. Data on the patients studied and implants placed Patients with narrow implants (n=20) Patients with conventional implants (n=20) Total (n=40) Gender Male Female Male Female Male Female 6 (30%) 14 (70%) 11 (55%) 9 (45%) 17 (42.5%) 23 (57.5%) Age <61 61-70 >70 <61 61-70 >70 <61 61-70 >70 5(25%) 10(50%) 5(25%) 4(20%) 10(50%) 6(30%) 9(22.5%) 20(50%) 11(27.5) Tobacco use Yes No Yes No Yes No 5 (25%) 15 (75%) 0 (0%) 20 (100%) 5 (12.5%) 37 (87.5%) Periodontitis Yes No Yes No Yes No 12 (60%) 8 (40%) 9 (45%) 11 (55%) 21 (52.5%) 19 (47.5%) Table 1: Descriptive data of the sample. Implants (whole sample) (n=82) Implants (1 implant per patient) (n=40) Gender Male Female Male Female 41 (50%) 41 (50%) 17 (42.5%) 23 (57.5%) Age <61 61-70 >70 <61 61-70 >70 13 (15.9%) 48 (58.5%) 21 (25.6%) 9 (22.5%) 20 (50%) 11 (27.5%) Arch location Maxilla Mandible Maxilla Mandible 41 (50%) 41 (50%) 21 (52.5%) 10 (47.5%) Bone regeneration Yes No Yes No 17 (20.7%) 65 (79.3%) 9 (22.5%) 31 (77.5%) Tobacco use Yes No Yes No 7 (8.5%) 75 (91.5%) 5 (12.5%) 37 (87.5%) Periodontitis Yes No Yes No 46 (56.1%) 36 (43.9%) 21 (52.5%) 19 (47.5%) Prosthetic restoration Single-unit Splinted Overdenture Single-unit Splinted Overdenture 27 (32.9%) 32 (39%) 23 (28%) 16 (40%) 14 (35%) 10 (25%) Table 2: Data from the selected implants for case-control study. can be seen in Table 1 and Table 2. If the sample was restricted to one implant per patient, only 40 implants were analyzed (Table 2). No significant differences in BL were found when comparing narrow implants with conventional implants after 2 years of implants loading. The BL variable was analyzed in addition to its correlation with other variables (bone regeneration, previous periodontal disease, type of prostheses, age…) using one implant per patient, and by analyzing only narrow implants (Table 3). No significant differences in BL were found when factoring for age or for patients with previous cases of periodontitis. Significant differences J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e82    Narrow Implant (n=20) Conventional Implant (n=20) Total (n=40) Age n/% by category BL index n % <61 61-70 >70 <61 61-70 >70 <61 61-70 >70 (5 / 25%) (10 / 50%) (5 / 25%) (4 / 20%) (10 / 50%) (6 / 30%) (9 / 22.5%) (20 / 50%) (11 / 27.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 2 40 2 40 1 20 3 30 7 70 0 0 3 60 1 20 1 20 2 50 1 25 1 25 3 30 6 60 1 10 4 66.7 1 16.7 1 16.7 4 44.4 3 33.3 2 22.2 6 30 13 65 1 5 7 63.6 2 18.2 2 18.2 Gender n/% by category BL index n % Male Female Male Female Male Female (6 / 30%) (14 / 70%) (9 / 45%) (11 / 55%) (17/42.5%) (23/57.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 2 33.3 3 50 1 16.7 6 42.9 7 50 1 7.1 6 54.5 5 45.5 0 0 3 33.3 3 33.3 3 33.3 8 47.1 8 47.1 1 5.9 9 39.1 10 43.5 4 17.4 Maxilla/Mandible n/% by category BL index n % Maxilla Mandible Maxilla Mandible Maxilla Mandible (13 / 65%) (7 / 35 %) (8 / 40%) (12 / 60%) (21 / 52.5%) (19 / 47.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 5 38.5 6 46.2 2 15.4 3 42.9 4 57.1 0 0 3 37.5 3 37.5 2 25 6 50 5 41.7 1 8.3 8 38.1 9 42.9 4 19 9 47.4 9 47.4 1 5.3 Periodontitis n/% by category BL index n % Yes No Yes No Yes No (12 / 60%) (8 / 40%) (9 / 45%) (11 / 55%) (21 /52.5%) (19 / 47.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 4 33 6 50 2 16.7 4 50 4 50 0 0 3 33.3 4 44.4 2 22.2 6 54.5 4 36.4 1 9.1 7 33.3 10 47.6 4 19 10 52.6 8 42.1 1 5.3 Bone regenerat. n/% by category BL index n % Yes No Yes No Yes No (5 / 25%) (15 / 75%) (4 / 20%) (16 / 80%) (9 / 22.5%) (31 / 77.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 1 20 4 8.80 0 0 7 46.7 6 40 2 13.3 0 0 3 75 1 25 9 56.3 5 31.3 2 12.5 1 11.1 7 77.8 1 11.1 16 51.6 11 35.5 4 12.9 Tobacco use n/ % by category BL index n % Yes No Yes No Yes No (5 / 25%)* (15 / 75%) (0/ 0%) (20/100%) (5 / 12.5%)* (35 / 87.5%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 0 5 100 0 0 8 53.3 5 33.3 2 13.3 - - - 9 45 8 40 3 15 0 0 5 100 0 0 17 48.6 13 37.1 5 14.3 Diameter n/% by category BL index n % Standard Narrow Standard Narrow Standard Narrow (0/ 0%) (20/100%) (20/100%) (0/0%) (20/50%) (20/50%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 - - - 8 40 10 50 2 10 9 45 8 40 3 15 - - - 9 45 8 40 3 15 8 40 10 50 2 10 Type of prosthes. n/% by category BL index n % Single Splinted Overd. Single Splinted Overd. Single Splinted Overd. (8 / 40%) (7 / 35%) (5 / 25%) (8 / 40%) (7 / 35%) (5 / 25%) (16 / 40%) (14 / 35%) (10 / 25%) 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 3 37.5 4 50 1 12.5 2 28.6 4 57.1 1 14.3 3 60 2 40 0 0 5 62.5 3 37.5 0 0 2 28.6 4 57.1 1 14.3 2 40 1 20 2 40 8 50 7 43.8 1 6.3 4 28.6 8 57.1 2 14.3 5 50 3 30 2 20 Table 3: Comparison of BL (Lagervall & Janson) in selected implants. * Significant differences (p <0.05). n= number of implants; % = percentage. 0-The implant does not show any BL. 1-The implant shows BL less than one-third of the total implant length. 2-The implant shows BL higher than one-third but less than two-thirds of the total implant length. 3-The implant shows BL higher than two-thirds of the total implant length. 4-The implant has failed and is outside of the patient’s mouth (Values 3 and 4 are not reflected in the table because they don´t represent any situation of the study). J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e83 were found when comparing BL with patient tobacco use (p < 0.05), in the sense that all implants placed on patients who used tobacco had some kind of BL. Data that compare BL of narrow implants, conventional implants or booth using or not bone regeneration didn’t show any significant differences. No significant differences were found when comparing bone loss of narrow implants with that of conventional implants. There were also no significant differences found when comparing BL with type of implant prostheses (Table 3). Discussion Both periapical (14,15) and panoramic (8) radiographs can be used to measure BL. Measurements can be taken directly in millimeters, comparing the position of the peri-implant bone in relation to the implant shoulder (16), or by dividing the implant into 3 equal parts from the implant shoulder to the apex and observing which third of the implant length the bone resides in (12). Although measurement in millimeters provide greater accuracy and greater statistical power, the complexity of measuring the BL in panoramic radiographs could subtract accurately measure. The use of Langervall-Jansson’s (12) scale for this study was selected because it had been validated in previous publications (8). This could be of interest when comparing the results of this study with those of other researchers. Limited bucco-lingual bone crest width has always been one of the main indications for placement of narrow implants (17-23). The BL of narrow implants without bone regeneration was compared with the BL of conventional implants that used bone regeneration to gain bucco-lin- gual crest width. No significant differences in rates of bone loss were found between both types of implants studied. With the limitations of the present study, both procedures appear to present similar predictability, although of course the use of narrow implants is less traumatic for the patient (24,25). The present study used narrow implants to rehabilitate all types of prosthesis (single crowns, splinted crowns, and overdentures). No significant differences in BL were found. However, it should be noted that given the sample size of the present study, further studies focusing on this point would be necessary. In the present study, no early or late failures were recorded in narrow implants. Regarding the survival rate of narrow implants, implant fracture is a frequent complication when using this type of implants (9,10). The present study found no incidence of fracture in the implants studied. Wang et al. (19) determined a survival rate of 93.5% based on 31 narrow implants observed over one year. On the other hand, Anitua et al. (2) placed 89 narrow implants, using prostheses similar to those in the present study (overdentures, single crowns and implants splinted) and evaluating the implants after 4 years. The results showed that only one implant was lost, resulting in an overall survival rate of 98.9%. It should be noted that in the study by Anitua et al., the follow-up radiograph carried out after 2 years (similar to the final radiographs in the present study), the average BL was 1.26 mm, or less than one-third of the implant length (2). The majority of the narrow implants in the present study fell within this range (51%). The present study fails to find statistical differences when comparing the BL of narrow implants placed in patients who had previously suffered periodontitis with implants placed in patients who had not. There is scientific evidence regarding the link between periodontitis and periimplantitis (26). However, in the present study, this evidence is not conclusive when BL is compared against to prior cases of periodontitis that were successfully treated. Despite this, there are other studies that support the findings indicating a link between the two variables (8,27). As in other studies, in our data we also found a higher BL in smokers, both narrow implants and standard (27,28). Within the confines of the present study, no significant differences in BL around implants were found when comparing narrow implants with conventional implants after 2 years of implants loading. In this sense, no differences were found when bone regeneration techniques had been used or not, or between types of prosthesis load supporting the implants. Smoking appears to increase BL around the implants studied, thus, practitioners should take greater precautions when placing implants in smokers. References 1. Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res. 2006;17:35-51. 2. Anitua E, Errazquin JM, de Pedro J, Barrio P, Begoña L, Orive G. Clinical evaluation of Tiny® 2.5- and 3.0-mm narrow-diameter implants as definitive implants in different clinical situations: a retrospective cohort study. Eur J Oral Implantol. 2010;3:315-22. 3. Davarpanah M, Martinez H, Tecucianu JF, Celletti R, Lazzara R. Small-diameter implants: indications and contraindications. J Esthet Dent. 2000;12:186-94. 4. Comfort MB, Chu FC, Chai J, Wat PY, Chow TWA. 5-year prospective study on small diameter screw-shaped oral implants. J Oral Rehabil. 2005;32:341-5. 5. Quek CE, Tan KB, Nicholls JI. Load fatigue performance of a single-tooth implant abutment system: effect of diameter. Int J Oral Maxillofac Implants. 2006;21:929-36. 6. Romeo E, Lops D, Amorfini L, Chiapasco M, Ghisolfi M, Vogel G. Clinical and radiographic evaluation of small-diameter (3.3-mm) implants followed for 1-7 years: a longitudinal study. Clin Oral Implants Res. 2006;17:139-48. 7. Esposito M, Grusovin MG, Felice P, Karatzopoulos G, Worthington HV, Coulthard P. The efficacy of horizontal and vertical bone augmentation procedures for dental implants - a Cochrane systematic review. Eur J Oral Implantol. 2009;2:167-84. 8. Corcuera-Flores JR, Alonso-Domínguez AM, Serrera-Figallo MÁ, Torres-Lagares D, Castellanos-Cosano L, Machuca-Portillo G. Relationship Between Osteoporosis and Marginal Bone Loss in Osseointegrated Implants: A 2-Year Retrospective Study. J Periodontol. 2016;87:14-20. J Clin Exp Dent. 2020;12(1):e79-84. Bone loss around narrow implants 2-years after loading e84 9. Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res. 2000;11:156-8. 10. Zinsli B, Sägesser T, Mericske E, Mericske-Stern R. Clinical evaluation of small-diameter ITI implants: a prospective study. Int J Oral Maxillofac Implants. 2004;19:92-9. 11. Klein MO, Schiegnitz E, Al-Nawas B. Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants. 2014;29:43-54. 12. Grusovin MG, Coulthard P, Worthington HV, Esposito M. Maintaining and recovering soft tissue health around dental implants: a Cochrane systematic review of randomised controlled clinical trials. Eur J Oral Implantol. 2008;1:11-22. 13. Perrotti V, Ravera L, Ricci L, Doi K, Piattelli A, Shibli J, et al. Radiographic comparison of periimplant bone resorption and assessment of survival rates of 2 implant systems: a 10-year prospective multicenter study. Implant Dent. 2015;24:77-82. 14. Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. I: Clinical and radiographic results. Clin Oral Implants Res. 2007;18:699-706. 15. Lagervall M, Jansson LE. Treatment outcome in patients with peri-implantitis in a periodontal clinic: A retrospective study. J Periodontol. 2013;84:1365-73. 16. Buduneli N, Baylas H, Buduneli E, Türkoglu O, Köse T, Dahlen G. Periodontal infections and preterm low birth weight: a case-control study. J Clin Periodontol. 2005;32:174-81. 17. Ioannidis A, Gallucci GO, Jung RE, Borzangy S, Hämmerle CH, Benic GI. Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. J Clin Periodontol. 2015;42:1060-70. 18. Benic GI, Gallucci GO, Mokti M, Hämmerle CH, Weber HP, Jung RE. Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study. J Clin Periodontol. 2013;40:1052-61. 19. Wang HL, Okayasu K, Fu JH, Hamerink HA, Layher MG, Rudek IE. The success rate of narrow body implants used for supporting immediate provisional restorations: a pilot feasibility study. Implant Dent. 2012;21:467-73. 20. Lazzara RJ. Criteria for implant selection: Surgical and prosthetic considerations. Pract Periodontics Aesthet Dent. 1994;6:55-62. 21. Buser D, Dula K, Hess D, Hirt HP, Belser UC. Localized ridge augmentation with autograftsand barrier membranes. Periodontol 2000. 1999;19:151-63. 22. Salama H, Salama M, Garber D, Adar P. Developing optimal peri-implant papillae within the esthetic zone: guided soft tissue augmentation. J Esthet Dent. 1995;7:125-9. 23. Mazor Z, Steigmann M, Leshem R, Peleg M. Mini-implants to reconstruct missing teeth in severe ridge deficiency and small interdental space: a 5-year case series. Implant Dent. 2004;13:336-41. 24. Von Arx T, Buser D. Horizontal ridge augmentation using autogenous block grafts and the guided bone regeneration technique with collagen membranes: a clinical study with 42 patients. Clin Oral Implants Res. 2006;17:359-66. 25. Oh TJ, Meraw SJ, Lee EJ, Giannobile WV, Wang HL. Comparative analysis of collagen membranes for the treatment of implant dehiscence defects. Clin Oral Implants Res. 2003;14:80-90. 26. Lopez-Piriz R, Morales A, Giménez MJ, Bowen A, Carroquino R, Aguilar L, et al. Correlation between clinical parameters characterising peri-implant and periodontal health: a practice-based research in Spain in a series of patients with implants installed 4-5 years ago. Med Oral Patol Oral Cir Bucal. 2012;17:e893-901. 27. Casado PL, Pereira MC, Duarte ME, Granjeiro JM. History of chronic periodontitisis a high risk indicator for peri-implant disease. Braz Dent J. 2013;24:136-41. 28. Cecchinato D, Bengazi F, Blasi G, Botticelli D, Cardarelli I, Guali- ni F. Bone level alterations at implants placed in the posterior segments of the dentition: outcome of submerged/non-submerged healing. A 5-year multicenter, randomized, controlled clinical trial. Clin Oral Implants Res. 2008;19:429-31. Conflict of interest The authors have declared that no conflict of interest exist.