Citation: Misák, P.; Kocáb, D.; Bayer, P.; Vymazal, T.; Rovnaníková, P. Effect of De-Icing Chemicals on Concrete Scaling: The Role of Storage Water. Materials 2023,16, 4928. https://doi.org/10.3390/ ma16144928 Academic Editor: Qing-feng Liu Received: 20 June 2023 Revised: 4 July 2023 Accepted: 5 July 2023 Published: 10 July 2023 Copyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). materials Article Effect of De-Icing Chemicals on Concrete Scaling: The Role of Storage Water Petr Misák * , Dalibor Kocáb , Patrik Bayer, Tomáš Vymazal and Pavla Rovnaníková Faculty of Civil Engineering, Brno University of Technology, Veveˇrí 331/95, 602 00 Brno, Czech Republic;
[email protected] (D.K.);
[email protected] (P.B.);
[email protected] (T.V.); [email protected].cz (P.R.) *Correspondence:
[email protected]; Tel.: +420-541-147-831 Abstract: This paper deals with the effect of the character of the water used for the water storage of concrete test specimens on the results of tests for resistance to de-icing chemicals. Two experiments were conducted to investigate the effect of the content of free CO 2 in water and leaching of calcium hydroxide from concrete on the test results. In the first experiment, the resistance of mortars to water and de-icing chemicals was investigated. It was found that the character of the water storage, i.e., fresh water vs. previously used water, can significantly affect the test results. The second experiment focused on investigating the effect of the content of free CO 2 in water on the test results. It was found that the content of free CO 2 in the water can statistically significantly influence the test results. In conclusion, the paper shows that the character of the water used for water storage of concrete test specimens and the content of free CO 2 in water are essential factors that can significantly affect the results of concrete resistance tests to de-icing chemicals. Further research is needed to understand these influences and their potential use to improve the resistance of concrete. Keywords: concrete; scaling; de-icing chemicals; water storage; statistical analysis; surface layer test 1. Introduction Concrete is the most widely used material in the construction industry. Indeed, it is the second most used material on Earth after water [ 1 ]. However, the production of concrete is associated with sustainability issues since it is made primarily from cement, aggregate, and water, and each component directly impacts the environment [ 2 ]. Global cement production in 2021 was approximately 4.1 billion tonnes [ 3 ], while annual concrete consumption is about seven times higher [ 4 ]. The production of Portland cement, until recently the primary component of concrete, is responsible for about 7–8% of global CO 2 emissions [ 5 ]. This significant carbon footprint leads to growing concerns about the sustainability of concrete structures and the depletion of natural resources such as aggregate or water [6–8] . Sustainability assessment tools include three fundamental pillars of sustainability—economic, ecological, and socio-cultural [ 9 ]—and designing and building durable structures is closely related to at least the first two pillars. Durability is a very general term, as it is not defined in terms of time, for example, compared to the service life of structures. When assessing the durability of a material, it is necessary to precisely define the environment in which it is to be evaluated [ 10 ]. The durability of concrete can be characterised by its ability to resist the action of external and internal agents, with the mode of failure of the concrete being highly dependent on the type and intensity of the action. The same concrete may exhibit a certain level of resistance to the action of soft (low mineralised) waters (this is corrosion caused by the leaching of calcium hydroxide; see, e.g., [ 11 ]) yet at the same time, a completely different level of resistance to the action of sulphates on concrete (this internal structural damage is caused by the increase in the volume of products of the corrosion reaction; see, e.g., [ 12 ]). One of Materials 2023,16, 4928. https://doi.org/10.3390/ma16144928 https://www.mdpi.com/journal/materials
Materials 2023,16, 4928 2 of 15 the basic durability properties of concrete in mild climates is undoubtedly its resistance to frost exposure [ 13 ]. This refers to the ability of concrete to resist the repeated alternation of positive and negative temperatures under simultaneous exposure to water, high humidity, or water in combination with de-icing chemicals. The alternation of positive and negative temperatures has no significant adverse effect on dry concrete [14]. If a concrete structure or a part of it is exposed to water and alternating positive and negative temperatures, it is necessary to assess whether the concrete surface is also affected by any de-icing chemicals—most often by salt and the resulting NaCl solution, which may affect the concrete surface directly or in the form of salt mist or spray. When a de-icing chemical is applied to concrete, the degradation processes completely differ from those in concrete only exposed to water, freezing, and thawing. Without the action of de-icing chemicals, water will enter the pore structure of the concrete, due to absorption, and will freeze there at sub-zero temperatures. Consequently, there is a risk of micro-cracks and then cracks in the internal structure of the concrete, i.e., the concrete may become damaged. On the other hand, scaling due to salts is defined as surface damage. This is caused by frost and the resulting crystallisation of the salt solution in the surface layer of the concrete [ 15 , 16 ]. The concrete scaling mechanism is quite different from that of freeze–thaw, which causes water to crystallise in the internal structure of concrete, thereby causing it to fail. In the case of scaling, it is a surface action only. While this does not affect the quality of the concrete inside the structure, it makes it sensitive to the penetration of water and other aggressive agents into its structure. This reduces the overall resistance of the concrete and, consequently, the service life of the structure, as well as the risk of reinforcement depassivation. Scaling was extensively studied and described many years ago, but is still remains a subject of many papers today; see, e.g., [ 17 – 22 ]. The most fundamental findings in the study of concrete scaling are: • Damage to the surface layer of concrete is significantly worse when the water applied to the concrete surface contains a certain amount of solute [23]. • The effectiveness of the concentration is almost independent of the character of the de-icing chemical in the solution (e.g., salts, urea). All these de-icing chemicals have been found to have similar effects on concrete [24]. • Damage to the surface layer of concrete is initially reflected in the formation of small chips or flakes of material that gradually fall off the surface [25]. • Without a free liquid with de-icing chemicals on the surface of the concrete, actual scaling will not occur, even when the concrete is saturated with water and subjected to alternating freeze–thaw cycles [26]. • The concentration of salts in the liquid applied to the concrete surface is more important than the concentration of the liquid in the pores of the internal structure of the concrete [23]. • The resistance of concrete to scaling is generally relatively low, but can be increased significantly by adding an air-entraining mixture to the concrete [24,27–29]. Testing the resistance of a concrete surface to scaling is quite difficult itself. Several standards and guidelines, both in Europe and North America, define the testing procedure differently (see Section 2). Many factors, some of which are listed above, will influence the outcome of a scaling test. At the same time, these tests are characterised by relatively high variability in the resulting values, including repeatability and reproducibility [ 30 ]. The tests deal with the length and temperature of the freeze-thaw cycles, the test specimen surface area, the characteristics of the de-icing chemicals, etc. Still, the effect of the water storage in which the test specimens are placed before the test has yet to be considered. It is reasonable that when testing a cut through a test specimen (e.g., the procedure according to standard [ 31 ]), the water in the water storage does not influence the test result. However, it is also reasonable that the surface should be tested rather than the cut through the specimen, as this is significantly more representative of the actual behaviour of the concrete in the structure. In this case, the water in which the specimens are stored before the test may have an influence.
Materials 2023,16, 4928 3 of 15 This paper deals with this overlooked effect and presents the results of two consecutive experiments. The pilot experiment showed that the level of water saturation with calcium hydroxide in the water storage affects the results of concrete scaling tests. The second, larger experiment further refined the results of the pilot experiment and more precisely defined the conditions under which concrete scaling test results can be significantly affected. 2. Testing Methods The basic concept of all methods that evaluate the resistance of concrete to the action of de-icing chemicals is similar. The test specimens to which the chemical solution is applied are placed in a device which allows automatic cycling between positive and negative temperatures. The main parameters and procedures of the various tests by which the resistance of concrete to scaling can be evaluated are briefly described below. 2.1. Procedure According to SS 13 72 44 [32] This test, developed in Sweden, is called the “Borås test method” or the “slab test” [ 19 ] and is one of the basic methods. The test requires a minimum of four specimens with a tested area greater than 0.0225 m 2 . The recommended size of the specimens is 150 mm ×150 mm ×50 mm . The test is conducted one-dimensionally, the change in temperature and humidity affects only the surface to be tested, and the other specimen surfaces are insulated. Not more than 15 min before the test, a 3% NaCl solution is applied to the test surface up to a height of 3 mm. The test cycles between temperatures of − 18 ° C and +20 ° C, with a cycle time of 24 h . The test evaluation is usually conducted after 7, 14, 21, 28, 42, and 56 cycles. The result is the cumulative amount of material scaled off the specimen in kg/m2[32]. 2.2. Procedure According to CEN/TS 12390-9 [31] This test method is based on the standard [ 32 ] and differs only in minor details—the testing is conducted on the cutting surface of the test specimen, cycling between temperatures of − 20 ° C and +20 ° C. This standard [ 31 ] is also the basis for the standards used in Lithuania, France, and the USA. 2.3. Procedure According to RILEM TC 117-FDC/CDF [33] This test method is used in Germany. It is necessary to produce five or more specimens with a test area of more than 0.08 m 2 —for example, test cubes ( 150 mm ×150 mm ×150 mm ). The mould for the cube production is covered with Teflon foil in the middle, and no demoulding agent may be used during the production. The surface to be tested is adjacent to the Teflon surface. The specimens are placed on pads in an automatic device into which a 3% NaCl solution is poured to submerge 5 mm of the cubes. The minimum test temperature is − 20 ° C and the maximum is +20 ° C. One cycle takes 12 h, and the result is the cumulative amount of material that has scaled off from the specimen in kg/m 2 after 14 and 28 cycles (4 and 6 cycles are also recommended [33]. 2.4. ASTM C672/C672M-12 Procedure [34] According to the American Standard [ 34 ], at least two specimens with a minimum test area of 0.045 m 2 and a height greater than 75 mm must be tested. A 4% CaCl 2 solution is poured on the test specimen up to a height of 6 mm (3% NaCl can also be used). The test specimens are tested by alternating temperatures between − 18 ° C and +23 ° C; the duration of one cycle is 24 h and a visual inspection of the surface to be tested is conducted after every fifth cycle. The final evaluation is performed after 50 cycles [34]. 2.5. Procedure According to MTO LS-412 and BNQ NQ 2621-900 [35] The MTO LS-412 test procedure is used in Ontario, Canada. The test is performed on at least two specimens with dimensions 300 mm × 300 mm × 75 mm. A 3% NaCl solution is applied to the test surface up to a height of 6 mm, and the specimen is then placed in a
Materials 2023,16, 4928 4 of 15 device in which it is cyclically frozen at − 18 ° C and thawed at +25 ° C. One cycle lasts 24 h, and the condition of the test area is visually assessed after every fifth cycle [35]. The BNQ test procedure is used in the province of Quebec in Canada. The minimum number of specimens to perform the test is two, with a minimum tested area of 0.05 m 2 . A 3% NaCl solution is poured onto the test specimens, which must then be covered with a waterproof membrane to prevent evaporation. The test specimens are exposed to cyclic temperature changes from − 18 ° C to +25 ° C in an automatic test chamber for 24 h per cycle. After 7, 21, 35, and 56 cycles, the amount of the material that has scaled off from the surface of the tested area is determined, and the test result is the cumulative amount of the scaled off material from the specimen in kg/m2after 56 cycles [35]. 2.6. Procedure According to ˇ CSN 73 1326 [36] This test method is commonly used in the Czech Republic and a slightly modified version in Slovakia. The standard [ 36 ] lists three procedures according to which the test can be performed. Only method A (DiCh-A method) will be described in detail here, as it was used for the experiment described below. The test is conducted on three test cubes (150 mm × 150 mm × 150 mm). After removal from the moulds, the specimens are placed in water storage at 20 ° C. When the concrete is 28 days old, an automatic cycling test is started, where the upper surface of the specimen is tested without any modification. The individual test specimens are placed in test containers made of a non-corrosive material, which allows the test specimens to be immersed in a 3% NaCl solution. The material that scales off from the specimen is captured. The solution is poured into the container so that the test cubes are immersed to 5 mm around their circumference. One freeze–thaw cycle takes 2 h, the minimum temperature is − 15 ° C, and the maximum is +20 ° C. This is a relatively quick test, at least compared to other standards. After every 25th cycle, the amount of material that has scaled off from the specimen surface in the dried state is determined. The surface resistance of cement concrete to water and de-icing chemicals is given by the amount of the scaled off material from the specimen in g/m 2 after a certain number of cycles. More information on this method can be found, for example, in papers [37]. 3. Experimental Two sub-experiments were conducted as part of this study. Three laboratories participated in the first experiment, which can be called a pilot. The motivation for this experiment was the repeated failure of one of the laboratories to participate in inter-laboratory comparison proficiency testing programmes. The laboratory tried to determine the cause of long-term higher values of the amounts of scaled off material from specimens within the DiCh-A testing method. It was assumed that the reason might be the water where the concrete specimens were cured before the actual testing. This was because the laboratory cleaned the water storage tanks significantly more frequently than is common practice. An experiment was, therefore, conducted where one set of test specimens was cured in water where other specimens had been previously stored. A second set of test specimens was placed in fresh water. The aim was to determine whether the water chemistry, i.e., freshwater vs. previously used water, could significantly influence the results of the tests performed by the DiCh-A method. As was subsequently discovered, an important factor that significantly influenced the test results was that each laboratory used water from their local sources. To investigate this effect, a further large-scale experiment was designed to test whether the content of free CO 2 in the water storage could statistically significantly affect the test results. In this case, a more extensive set of 150 mm concrete test cubes had already been prepared.
Materials 2023,16, 4928 5 of 15 3.1. Pilot Experiment—Mortar Testing The pilot experiment involved 18 test specimens with dimensions 40 ×40 ×160 mm produced from mortar with EN 196-1 standard silica sand [ 38 ] and CEM I 42.5 R cement. Each laboratory received six test specimens. Three test specimens were always placed in water where other concrete test specimens had previously been cured. It was, therefore, water which was a saturated solution of calcium hydroxide (used water). The other three specimens were placed in fresh water from their local sources (fresh water). The results were statistically processed after performing 100 freeze–thaw cycles according to the DiCh-A method and after determining the amount of scaled off material from the specimen after every 25 cycles. First, the equality of the means of the results of the tests performed by the three laboratories was tested at the 0.05 significance level. The onefactor analysis of variance (ANOVA) was used. The tests were performed separately for each level of freeze–thaw cycles and the water used in the water storage. Based on the analyses performed, the differences between the test results are statistically significant at each experiment level. Therefore, the results of the tests conducted by the three laboratories are statistically significantly different. This is also illustrated in a graphical representation (see Figure 1). Figure 1. Mortar scaling resistance test results. The tests performed by the A-lab show significantly higher values of the scaled off material in g/m 2 at all experiment levels, i.e., at 25 freeze–thaw cycle intervals. However, there were more interesting observations from the point of view of the objective of the experiment performed. In the design of the experiment, it was assumed that using fresh
Materials 2023,16, 4928 6 of 15 water to store the test specimens would increase the results of the tests performed according to the DiCh-A method. The results of laboratories B and C showed a slight increase in the amount of scaled off material from the specimens. However, in the case of laboratory A, the effect of the character of the water storage is exactly the opposite. This effect is most evident after 100 freeze–thaw cycles. The average values obtained differ by more than 500 g/m 2 , corresponding to an almost 50% increase in the scaled off material from the specimen surface. By analysing the test results, the authors concluded that the opposite effect in the different laboratories could be caused by the fact that each laboratory used water from their local source to store the test specimens. It was discovered that the DiCh-A method’s test results could be mainly influenced by the content of free CO 2 in the water used for water storage. As will be shown later in the paper, also based on the results of microscopic analysis, a very thin CaCO 3 layer forms on the test specimens at higher free CO 2 content in the water, which leads to a certain hardening of their surface. This hardening does not affect the strength characteristics of the concrete but may affect the results of concrete surface layer tests, such as the amount of scaled off material in the specimen according to the DiCh-A method. 3.2. The Second Experiment—Testing Concrete The significant differences from the pilot experiment were as follows. The experiment was conducted in a proficiency testing programme involving 23 mostly accredited testing laboratories. By participating in similar precision experiments, the laboratories have demonstrated their proficiency in the testing procedures under consideration. The organiser provided nineteen laboratories with three cube-shaped test specimens with an edge of 150 mm . The remaining four laboratories received nine of those test specimens. All 105 test specimens were produced from one batch, at one time, in one place, and using the same mould type. Fresh concrete of class C 30/37 XF4 S4 D max 16 was made at the concrete plant ina1m3mixer. The composition of the fresh concrete is given in Table 1. Table 1. The composition of fresh concrete. Component kg/m3 Cement CEM I 42.5 R (Morká cement plant, CZ) 400 Fine aggregate 0–4 mm (Bratˇcice, CZ) 807 Coarse aggregate 8–16 mm (Olbramovice, CZ) 915 Air-entraining admixture LPS A 94 (Sika, CZ) 1 Plasticizing admixture SVC-4035 (Sika, CZ) 2.2 Water 182 After 24 h from the concrete mixing, the test specimens were de-moulded and placed in different water storage tanks. Sixty-nine specimens were placed in an empty and clean tank that was filled with fresh water from the water supply (Figure 2a). These specimens were used for the main part of the inter-laboratory comparison (hereinafter referred to as “fresh water”). The other 12 test specimens were placed in a tank with previously used water for concrete specimens not intended for this experiment. This water could be considered a saturated solution of calcium hydroxide (Figure 2b), and this storage is referred to as “previously used water”. The remaining 12 specimens were placed in a tank with a constant inflow of water from the water supply (Figure 2c), and this storage is referred to as “slow flowing water”. The water flow rate was adjusted so that saturation with concrete leachates could not occur throughout the maturation process, i.e., for the remaining 27 days. The aim was to maximise the leaching of calcium hydroxide from the test specimens. The differences in water properties in the water storage were also monitored by measuring the pH value: slow flowing water, 6.67; fresh water, 11.44; previously used water, 13.33. The pH measurements were taken with an automatic temperature-compensated probe at 14 days and then 21 days after production. The values are from the second measurement. At
Materials 2023,16, 4928 7 of 15 28 days after production, all test specimens were wrapped immediately after removal from water storage in impermeable foil and distributed to the participants of the experiment. Figure 2. Arrangement of test specimens in ( a ) fresh water, ( b ) previously used water, and ( c ) slow flowing water. 4. Results and Discussion 4.1. Validation of Test Results The first step in the analysis of the main part of the experiment was to evaluate the statistical performance of the four laboratories that participated in the main part of the experiment. This was to assess whether the results of the laboratories were statistically significantly different from the results of the tests performed by other laboratories in the large-scale inter-laboratory comparison (ILC). The results of the tests performed by 23 laboratories according to ˇ CSN 73 1326 [ 36 ] on specimens under the same conditions were assessed. These specimens were cured in a water storage environment called “fresh water”. Before the actual assessment of statistical performance using the so-called z-score, it was evaluated whether any of the test results could be considered outliers. For this purpose, the Cochran and Grubbs tests were performed at a significance level of 0.01 [ 39 ]. Based on exceeding the critical values of the tests, one laboratory was excluded from the experiment due to outlier results at all experiment levels. Due to the large scale of the ILC evaluation, only the outputs after 100 freeze–thaw cycles are presented below. The mean values and sample standard deviations of the test results of all laboratories are shown in Figure 3. As can be observed from the graph, the performance of one of the
Materials 2023,16, 4928 8 of 15 laboratories was classified as “unsatisfactory” and that of one laboratory as “problematic” based on the z-score [ 40 ]. The assigned value, indicated by the blue line in Figure 3, was evaluated by iterative algorithm A [41]. This algorithm has the advantage of being robust and, thus, less sensitive to outliers than the ordinary arithmetic mean. Threshold values for |z-score|>2 and 3 are shown in Figure 3in red. Figure 3. Evaluation of the results of the inter-laboratory comparison. The ILC evaluation also determined a repeatability value of r= 50.1% and reproducibility of R= 202.6% according to [ 39 ]. These values indicate how much variability can be expected between the results of tests performed by one laboratory (repeatability) and multiple laboratories (reproducibility). According to [ 36 ], the test procedures show significantly higher r and R values than other commonly used concrete testing procedures. This is also evident from the results of other ILCs, which can be found, e.g., at [42]. However, the most important outcome of this part of the experiment is that the performance of the laboratories marked A to D, i.e., the laboratories participating in the main part of the experiment, was found to be satisfactory. The resulting z-scores even lie in the interval h−1;1i, indicating that the outputs of these laboratories can be considered satisfactory. 4.2. Assessment of Homogeneity of Test Results The next phase of the evaluation focused only on the results of laboratories A to D, which measured test specimens stored during curing in water labelled “fresh water” and the other types of water storage described above. The results of the tests, including the means and sample standard deviations, are shown in Figure 4. Figure 4presents the test specimens of laboratory A after 100 freeze–thaw cycles. It is noticeable from the surface colouration that the surface has been damaged differently by de-icing chemicals (see Figure 5). The first step in the statistical analysis of the results of laboratories A to D was to consider whether the differences between the individual test results exhibit statistically significant differences. The aim was to determine whether the results of the tests conducted each time on specimens from the same water storage can be mixed and, thus, be considered as a homogeneous statistical set suitable for further evaluation. At the same time, these tests will demonstrate whether the experimental outputs can be influenced by a higher level of reproducibility (see above). The so-called analysis of variance (ANOVA) was applied, whose null hypothesis is the equality of means of the results between laboratories. Testing was performed at the 0.01 level of significance. The results of the ANOVA tests, presented
Materials 2023,16, 4928 9 of 15 as p-values in Table 2, indicate no statistically significant differences between the results of the different laboratories. At the same time, the red cross in Figure 6indicates individual test results that were flagged as outliers by the Grubbs test after mixing the values and were, therefore, excluded from the experiment. A graphical representation of all non-outlying results is shown in Figure 7. The test results of one specimen that showed a significantly higher amount of scaled off material from the specimen after 50, 75, and 100 freeze–thaw cycles were excluded. Table 2. Results of statistical tests. Water Storage Number of Cycles ANOVA p-Value Shapiro Test p-Value (Normality Test) Shapiro Test p-Value (Normality Test) after Excluding Outliers Slow flowing water 25 0.141 0.810 - 50 0.169 0.633 - 75 0.065 0.174 - 100 0.038 0.262 - Fresh water 25 0.043 0.992 - 50 0.047 0.227 - 75 0.099 0.861 - 100 0.131 0.647 - Previously used water 25 0.052 0.044 0.204 50 0.045 0.001 0.232 75 0.061 0.001 0.362 100 0.072 0.003 0.654 Figure 4. Comparison of test results of the main part of the experiment. The test results of each laboratory are shown for all multiples of freeze–thaw cycles. From the left: 25, 50, 75 and 100 F–T cycles, according to [36]: (a) Slow flowing water (b) Fresh water (c) Previously used water.