scieee AI-readable full text Open interactive document viewer

Retinal status analysis method based on feature extraction and quantitative grading in OCT images

Fu, Dongmei; Tong, Hejun; Zheng, Shuang; Luo, Ling; Gao, Fulin; Minář, Jiří

Abstract

Background: Optical coherence tomography (OCT) is widely used in ophthalmology for viewing the morphology of the retina, which is important for disease detection and assessing therapeutic effect. The diagnosis of retinal diseases is based primarily on the subjective analysis of OCT images by trained ophthalmologists. This paper describes an OCT images automatic analysis method for computer-aided disease diagnosis and it is a critical part of the eye fundus diagnosis. Methods: This study analyzed 300 OCT images acquired by Optovue Avanti RTVue XR (Optovue Corp., Fremont, CA). Firstly, the normal retinal reference model based on retinal boundaries was presented. Subsequently, two kinds of quantitative methods based on geometric features and morphological features were proposed. This paper put forward a retinal abnormal grading decision-making method which was used in actual analysis and evaluation of multiple OCT images. Results: This paper showed detailed analysis process by four retinal OCT images with different abnormal degrees. The final grading results verified that the analysis method can distinguish abnormal severity and lesion regions. This paper presented the simulation of the 150 test images, where the results of analysis of retinal status showed that the sensitivity was 0.94 and specificity was 0.92.The proposed method can speed up diagnostic process and objectively evaluate the retinal status. Conclusions: This paper aims on studies of retinal status automatic analysis method based on feature extraction and quantitative grading in OCT images. The proposed method can obtain the parameters and the features that are associated with retinal morphology. Quantitative analysis and evaluation of these features are combined with reference model which can realize the target image abnormal judgment and provide a reference for disease diagnosis

Full text

Retinal status analysis method based onfeature extraction andquantitative grading inOCT images Dongmei Fu1* , Hejun Tong1, Shuang Zheng1, Ling Luo2, Fulin Gao2 and Jiri Minar3 Background Optical coherence tomography (OCT) is an invivo imaging technique that could rapidly acquire high resolution cross-section images of biological tissues microstructure [1]. The most significant medical contribution of OCT is the ophthalmology area, as it could provide the retinal structure and functional images that no other noninvasive diagnosis Abstract Background: Optical coherence tomography (OCT) is widely used in ophthalmology for viewing the morphology of the retina, which is important for disease detection and assessing therapeutic effect. The diagnosis of retinal diseases is based primarily on the subjective analysis of OCT images by trained ophthalmologists. This paper describes an OCT images automatic analysis method for computer-aided disease diagnosis and it is a critical part of the eye fundus diagnosis. Methods: This study analyzed 300 OCT images acquired by Optovue Avanti RTVue XR (Optovue Corp., Fremont, CA). Firstly, the normal retinal reference model based on retinal boundaries was presented. Subsequently, two kinds of quantitative methods based on geometric features and morphological features were proposed. This paper put forward a retinal abnormal grading decision-making method which was used in actual analysis and evaluation of multiple OCT images. Results: This paper showed detailed analysis process by four retinal OCT images with different abnormal degrees. The final grading results verified that the analysis method can distinguish abnormal severity and lesion regions. This paper presented the simulation of the 150 test images, where the results of analysis of retinal status showed that the sensitivity was 0.94 and specificity was 0.92.The proposed method can speed up diagnostic process and objectively evaluate the retinal status. Conclusions: This paper aims on studies of retinal status automatic analysis method based on feature extraction and quantitative grading in OCT images. The proposed method can obtain the parameters and the features that are associated with retinal morphology. Quantitative analysis and evaluation of these features are combined with reference model which can realize the target image abnormal judgment and provide a reference for disease diagnosis. Keywords: Retinal OCT images, Image processing, Morphological characterization, Feature quantification, Grade evaluation Open Access © 2016 The Author(s). This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. RESEARCH Fu et al. BioMed Eng OnLine (2016) 15:87 DOI 10.1186/s12938-016-0206-x BioMedical Engineering OnLine *Correspondence: [email protected] 1 School of Automation and Electrical Engineering, University of Science and Technology Beijing, Xueyuan Road 30, Haidian District, Beijing, China Full list of author information is available at the end of the article Page 2 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 method can perform. Several medical researchers used OCT to acquire retinal statistical characteristics and analyzed different kinds of fundus diseases, such as macular oedema caused by diabetic retinopathy [2], drusen and drusenoid pigment epithelium detachment caused by non-neovascular age-related macular degeneration [3], X-linked retinoschisis [4], epiretinal membrane, macular hole, central serous chorioretinopathy [5] etal. In addition, there are researches on statistical analysis of normal retinal thickness [6]. Ophthalmologists diagnose the fundus diseases by analyzing the change of retinal features in OCT images; however, OCT instruments can produce large amounts of data in a short time, so it is difficult to analyze all data by manual method. In most cases, only a small number of selected images are analyzed, and this could cause the wasting of medical resources. Furthermore, manual analysis results are very depending on ophthalmologist’s personal experience and there is also lack of uniform quantization and evaluation standards. Therefore, rapid, accurate, objective detection and quantification of retinal features is the key of medical OCT images research and diagnosis of ophthalmic diseases, and this study has important theoretical significance and practical value. In order to achieve the retinal features detection and quantification, computer image processing and analysis technologies have been widely applied in the field of medical OCT images. Quellec etal. [7] realized the automated identification of macular fluidfilled regions by analysis of retinal layer texture. Gregori etal. [8], Iwama etal. [9] and Chen etal. [10] utilized different methods to segment retinal drusen and made the different levels quantification and evaluation. The upper studies are aimed at the known cases of illness, and extract the pathological areas in image. Liu etal. [11, 12] utilized retinal geometry, texture, shape features to identify the presence of normal macula and each of three types of macular pathologies, but without the analysis of pathological severity degree. Koprowski etal. [13] described a method for automatic analysis of selected choroidal diseases by features definition and quantification. By using the feature data acquired from OCT, Koprowski etal. [14] also proposed an automatic method for the analysis of OCT images in assessing the severity degree of glaucoma. Xu etal. [15] segmented the nerve fiber layer and analyzed OCT data for glaucoma detection. These studies identified or classified the limited certain kinds of diseases according to the extracted pathologic features. The upper studies are either for the extraction of pathological area in known cases of illness or for the features extraction and classification of limited certain kinds of diseases. In practical diagnostic process, the obtained retinal images are usually complex and the abnormal categories would not be limited within the scope of certain kinds of known cases. Furthermore, retinopathy is gradually evolved and the abnormal early detection and early diagnosis has great significance. Therefore, in order to realize computer automatic analysis of retinal status, it is also needed to rely on the ophthalmologists’ practical diagnosis process to deal with different situations in reality. When ophthalmologists interpret retinal OCT images, they focus on the locations of the lesions occur (macular areas, internal limiting membrane, retinal pigment epithelium, nerve fiber layer, etc) and the feature morphologies (retinal thickness, overall shape change, boundary smoothness, boundary continuity, etc) that are conducive to abnormal judgment. And they compare the specific tissue structure morphology with the known Page 3 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 normal morphology. In the process of comparison, ophthalmologists do some extensive quantitatively analysis of the differences in morphology, such as retinal thickness (ratio) change, the morphological change of quantity, etc, and judge abnormal severity and lesion location. Finally ophthalmologists make the association between these morphological differences and corresponding disease categories, and give the diagnosis decision. Based on the process of ophthalmologists’ observation and analysis on fundus retinal morphology in OCT images, this paper computerized the analysis and decision-making process, and put forward a retinal status automatic analysis method. The ophthalmologists’ analysis process and the proposed retinal status automatic analysis process diagram are shown in Fig.1. In this paper, a normal retinal reference model is constructed to analogy the normal tissue structures that ophthalmologists are familiar with. Image processing methods such as boundary extraction, morphological characterization and features quantification are used to express of the ophthalmologists’ diagnosis process. Finally, evaluation of the results are presented by the way of abnormal grading. Material This study analyzed 300 retinal OCT images, including 200 images judged as normal by ophthalmologists and the remaining 100 images with various abnormalities, such as drusen, macular epiretinal membrane, macular edema and macular hole, etc. These images are from 300 participants, aged from 18 to 78 years and they are acquired using Optovue Avanti RTVue XR (Optovue Corp., Fremont, CA) from the 306th Hospital of People’s Liberation Army, Department of ophthalmology. This study is supported by the National Natural Science Foundation of China. Image analysis was carried out in Matlab. Retina is a transparent film layer located in the inner wall of eye. At present, the most advanced OCT instrument can distinguish 12 normal retinal tissue layers, as shown in Fig.2a. In the posterior pole of the retina, there is a funnel-shaped depression pale, and that is the optical center of eye, known as the macular region, as shown in Fig.2b. The structure and physiological activity of retina in this region are special, and it is easy to be affected by internal and external pathogenic factors. Therefore, this paper focuses on the morphological changes of retina in macular region. Retinal macula can be subdivided into three anatomical zones: (1) fovea, the center of macular region, and it is about 1.5mm in diameter, that is, a optic disc diameter. The center of fovea is called foveola and it is about 0.35mm in diameter. (2) parafovea, a circular ring area about 0.5mm outside the fovea, and it contains ganglion cells, inner nuclear layer and outer plexiform layer called Henle fiber. (3) perifovea, a circular ring area about 1.5mm outside the parafovea. Methods Image preprocessing andnormal retinal reference model Image standardization andde‑noising In the process of imaging, the OCT instrument auto focuses according to the size of the targets’ shape, changes the axial resolution of the image, and the retina appears with different degree of tilt in the image. So first of all, OCT images should be standardized. The aims of image standardization are: (1) unify the image size and axial resolution; (2) focus Page 4 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 on macular central area; (3) make the whole retina in a horizontal position, in order to ensure the unity of the follow-up feature extraction. The typical retinal OCT image has these characteristics: edge unclear, fuzzy and low signal-to-noise ratio, and thus de-noising is needed in preprocessing. The de-noising methods in OCT images mainly include complex domain methods [16, 17] and magnitude domain methods, while magnitude domain methods are more widely used and these methods may be studied in raw images domain [18–23] and sparse representation [24–26]. Five de-noising methods are compared in this paper, including Bayesian least squares– Gaussian scale mixture approaches (BLS-GSM) [18], non-local means (NL Means) [19], nonlinear complex diffusion filter (NCDF)[20], complex wavelet based dictionary learning methods (CWDL) [24] and Block-matching and 3D filtering (BM3D) [21]. Fig. 1 The contrast between ophthalmologist’s analysis process and computer automatic analysis process. The ophthalmologist’s practical diagnosis process is denoted with the dotted box on the left side and the dotted box on the right side shows the proposed retinal status computer automatic analysis process. a Original image, b image after standardization, c image de-noising results, d image boundary extraction results, e normal retinal OCT reference model Page 5 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 Contrast-to-noise ratio (CNR), texture preservation (TP), edge preservation (EP), and equivalent number of looks (ENL) were computed for each de-noising method to compare the performance of the de-noising algorithms. The mentioned values are computed based on methods discussed in [27]. Table1 shows the value of the measurements for each de-noising method of 20 OCT images, and the overall effect of BM3D algorithm is better than others. So BM3D algorithm was utilized in this paper for OCT image denoising processing. Normal retinal reference model In clinical practice, ophthalmologists compare the feature and morphology differences between specific targets and ’standard’, and take the differences as symptom information. This paper built normal retinal reference model as ’standard’ to compare differences in identifying specific targets and it is conducive to obtain quantitative features for medical diagnosis. When the macular lesions occur, internal limiting membrane (ILM) and retinal pigment epithelium (RPE) have morphological variation, and that is an important criteria of illness judgment. ILM is the inner boundary membrane of retina and RPE lower boundary is the outer boundary membrane of retina. Retina is defined between these two boundary membranes in medicine and some OCT instruments also take the detection data between these two membranes as retinal thickness data. So this paper chose ILM and RPE lower boundary to build the normal retinal reference model. Fig. 2 Diagram of normal retinal structure. a Normal retinal tissue layers image shot by OCT instrument. b Macular structure, including foveola, fovea, parafovea, perifovea regions Table 1 Value ofthe measurements foreach de-noising method BLS-GSM NL means NCDF CWDL BM3D CNR 14.05 ± 4.46 17.48 ± 3.45 19.34 ± 5.32 25.68 ± 5.95 31.79 ± 8.38 EP 0.88 ± 0.04 0.96 ± 0.04 0.77 ± 0.05 0.74 ± 0.08 0.75 ± 0.09 TP 0.58 ± 0.11 0.41 ± 0.29 0.19 ± 0.06 0.07 ± 0.05 0.03 ± 0.04 ENL 35.89 ± 14.79 283.53 ± 116.55 12.9 ± 4.87 86.62 ± 25.27 510.94 ± 402.32 Page 6 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 This paper randomly selected 100 images from the 200 normal OCT images as the data base of references’ models and the other 100 images are used to test the effectiveness of the reference model. ILM and RPE boundary extraction is the foundation for retinal reference model construction. There are many studies on retinal layers segmentation [28–34], and this paper used the relatively stable extraction method based on graph theory and dynamic programming from literature [28]. The generalized schematic of the layer segmentation algorithm and the construction of reference model are shown in Fig.3. On the basis of extracting ILM and RPE boundaries and unit conversion, take the average of unified boundaries as the normal retinal reference model, as shown the solid lines in Fig.4. The dotted lines in the figure are the variation range based on reference model standard deviation. Duan etal. [35] and Shen etal. [36] measured the macular thickness in healthy Chinese, and used OCT instruments are Stratus OCT (Carl Zeiss Meditec Inc., Jena, Germany) and Spectralis SD-OCT (Heidelberg Engineering, Heidelberg, Germany). Fast macular thickness scans were performed over macula within 6 mm in diameter, divided into 3 regions (central, inner, and outer, with a diameter of 1, 3 and 6 mm, respectively) and the specific metrical data are shown in Table2, including fovea minimum, average Fig. 3 The generalized layer segmentation algorithm schematic and the construction of reference model. The segmentation algorithm was based on graph theory and dynamic programming and the segmentation of retinal layer was achieved by finding the shortest path in the limited search region. The first segmented boundaries were in pixels and the unit was converted according to the axial resolution. The foveola locations in all images were unified and the averaged boundaries were reference model Fig. 4 Normal retinal reference model. The solid lines are the average boundaries of normal retinal ILM and RPE, as the normal retinal reference model. The dotted lines are the variation range based on reference model standard deviation. The horizontal axis shows the distance to foveola center, and the numerical value is consistent with the Fig. 2b. The vertical axis represents the axial distance, and the retina thickness changes around the macular regions can be seen Page 7 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 thickness of central macula, inner and outer regions. The same metrical data obtained from the above reference model are also presented in Table2. As the different data sources and thickness calculation methods, there are differences between the reference model and the numerical value in the literatures, but from the overall view, the thickness values of reference model are by a factor of about 1.25:1 larger than the values in literature [35] and 1:1.1 smaller than the values in literature [36]. The data showed that the reference model proposed in this paper is reliable. Computerized quantification ofretinal features In order to locate the position of lesion, the OCT image should be divided to regions before computation of quantification of retinal features. According to the anatomical definition of retina around macular regions, single OCT image is divided into five regions, namely, left perifovea (PE_L), left parafovea (PA_L), fovea (Fovea), right parafovea (PA_R), right perifovea (PE_R), as shown in Fig.5. The retinal morphological change is the indispensable basis for fundus anomaly judgment. When ophthalmologists analyze the retinal morphological change in OCT images, they focus on the retinal thickness, boundary smoothness and continuity. Retinal thickness is an important criterion for fundus disease diagnosis, and the location and severity of lesion could be determined by the change of thickness features. The size of retinal thickness data is related to the real condition of retinal tissue, instruments and the actual operation of the instruments. The data does not have the characteristics of Table 2 Normal macular measure thickness andreference model quantitative values ( µ m; mean ± standard deviations) Thickness feature/source Stratus OCT Spectralis SD-OCT Reference model Fovea minimum 150.3 ± 18.1 215.4 ± 13.6 202.6 ± 12.5 Central (1-mm diameter) 176.4 ± 17.5 257.9 ± 19.2 233.6 ± 15.0 Inner region (3-mm diameter) 255.3 ± 14.9 339.2 ±14.6 313.7 ±15.5 Outer region (6-mm diameter) 237.7 ± 12.4 299.1 ± 14.3 286.5 ± 21.9 Fig. 5 Schematic diagram of medical macular regional division. The green lines represent the medical macular regional division, including foveola, fovea, parafovea and perifovea. The red lines represent the upper and lower boundaries of retina. The white short line is the center position of foveola Page 8 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 feature invariant, therefore the definition of thickness ratio features can be more detailed to describe the geometrical features and thickness of retina. The standard deviation can reflect the degree of dispersion of a data set and the correlation coefficient is used to reflect the correlation between the variables. In this paper, the standard deviation and correlation coefficients were used to determine the relative degree and continuity between the target boundary and reference model. The gradient feature represents the change rate of parameters, and the curvature is a measure of the geometric uneven degree. So, the gradient and curvature features were used to express the smoothness of the boundary. In conclusion, this paper put forward the following three kinds of quantitative feature sets, as shown in Table3, in order to realize the computerized quantification of medical features that ophthalmologists focus on. The thickness features are defined as the average retinal thickness of different regions in Fig.4, and the definition of thickness ratio feature is TRRegions =TRegions/TFoveola . The morphological features are defined as follows: Suppose Y(i) is the discrete data of ILM/RPE curve, i=1, 2, 3 ...,W , W is the number of image horizontal pixels, namely, the width of image. Definition of L for the horizontal length of one area in Regions, 0<L≤W . Definition of regional mean curvature: where Y′(i)=Y(i+1)−Y(i) , Y′′(i)=Y′(i+1)−Y′(i)=Y(i+2)−Y(i) . Definition of regional mean horizontal gradient: Suppose Yref (i) is the discrete data of reference model ILM/RPE curve, and Ytar (i) is the discrete data of target ILM/RPE curve. Definition of correlation coefficient between target curve and the reference model in a certain area: where Yref is the regional mean of Yref (i) , and so is Ytar . (1) K = L i=1K(i) L,K(i)=|Y′′(i)| ( 1 +Y ′ (i) 2 ) 3 (2) ∇ Y= L i=1∇Y(i) L ,∇Y(i)=αY αx (i)=Y(i+1)−Y(i ) (3) r = L i=1(Yref (i)−Yref )(Ytar(i)−Ytar)  L i =1(Yref (i)−Yref )2·  L i =1(Ytar(i)−Ytar) 2 Table 3 Computerized quantification of retinal features (Regions = [PE_L, PA_L, Fovea, PA_R, PE_R]) Ophthalmologists focus features Computer quantitative features Feature type Retinal thickness Thickness feature ( TFoveola , TRegions ), Geometric features Thickness ratio feature ( TRRegions ) Boundary continuity Standard deviation ( σILM , σRPE ), Morphological features Correlation coefficient ( rILM , rRPE ) Boundary smoothness Gradient ( ∇YILM , ∇YRPE ), Morphological features Curvature ( KILM , KRPE ) Page 9 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 Definition of standard deviation between target curve and the reference model in a certain area: where D(i)=Ytar(i)−Yref (i) , D is the regional mean of D(i). Formulas (1)–(4) are unified expressions. According to the specific condition of ILM and RPE, these definitions can be respectively represented as KILM , KRPE , ∇YILM , ∇YRPE , rILM , rRPE , σILM , σRPE . According to the 100 normal OCT images which are used to construct the reference model, after statistical analysis and calculation, the features data of retinal thickness and retinal thickness ratio are shown in Tables4 and 5. Retinal abnormal grading decision-making The retinal abnormal degree and lesion location could be identified by the diversity factor between the extracted ILM, RPE boundaries and reference model based on the feature parameters in Tables3, 4 and 5 and the retinal feature value range around normal macula. Two kind of grading standard for evaluation of the abnormal degree, according to the different feature types, were proposed in this paper. (1) Geometric features (thickness and thickness ratio) grading standard can be seen in Table6 and Fig.6a, where Gtar represents the geometric features value of target image to be graded, Gref represents the geometric features value of reference model. The normal or not of the target image geometric features is judged by the deviation from reference model. Either large or small are abnormal, and the degree of abnormality is judged by the deviation. The deviation scope was determined by grading ratio factor and reference (4) σ =     1 L L  i =1 (D(i)−D)2 ) Table 4 Retinal thickness feature data ( µ m; mean ± standard deviations) Computer quantitative feature names Ref model value Foveola average thickness TFoveola 206.8 ± 13.2 Fovea average thickness TFovea 253.7 ± 14.1 Left parafovea average thickness TPA_L 320.2 ± 15.9 Right parafovea average thickness TPA_R 319.3 ± 15.6 Left perifovea average thickness TPE_L 296.1 ± 20.8 Right perifovea average thickness TPE_R 295.5 ± 20.1 Table 5 Retinal thickness ratio feature data Computer quantitative feature names Definition Ref model value Fovea thickness ratio TRFovea TFovea/TFoveola 1.22 ± 0.04 Left parafovea thickness ratio TRPA_L TPA_L/TFoveola 1.55 ± 0.10 Right parafovea thickness ratio TRPA_R TPA_R/TFoveola 1.54 ± 0.10 Left perifovea thickness ratio TRPE_L TPE_L/TFoveola 1.43 ± 0.13 Right perifovea thickness ratio TRPE_R TPE_R/TFoveola 1.43 ± 0.13 Page 16 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 abnormality has not yet affected the lower edge of RPE, so it has not been detected, which is the direction of further research in this paper. Conclusions With OCT data being generated in increasingly larger amounts and captured at higher resolution, there is a strong need for computer assisted analysis to support disease diagnosis and the automatic analysis of OCT images has remained an active field of research. We presented an automatic analysis method of fundus retinal status, based on boundary extraction, morphological characterization, feature quantification and grade evaluation. First, a normal retinal reference model was presented on the base of extracted ILM and RPE boundaries. Then, this paper proposed a set of retinal features extraction and quantification methods, for providing numerical reference standard on inspection of retinal status by OCT images. After obtaining the retinal feature parameters, this paper judged the anomalies of target image combined with the reference model and formulated grading method, so as to conveniently and clearly judge the abnormal region and severity. Different with former studies, like extraction of pathological area in known cases of illness or features extraction and classification of limited certain kinds of diseases, Our method would not limit the abnormal categories within the scope of certain kinds of known cases, because the retinal images are usually complex in practical diagnostic process. So the applicability and utility of our method is better in health screening and preliminary diagnosis of the retina. This paper proposed a general framework for the realization of computerized medical diagnosis of retina and it is also a potentially valuable tool for remote diagnosis applications. In future research, we will refine the reference model and make use of more image Fig. 13 The scatter plot of testing images. The features in each image were grouped and converted into a three dimensional data point. The normal and abnormal images labeled by ophthalmologist were marked for different scatter points. The testing images were judged normal or abnormal based on the 1/8 spherical surface in our algorithm. The points in the inner space of spherical surface were judged normal and the points in the outer space were judged abnormal. It can be seen from the image that the abnormal judgment method presented in this paper is basically consistent with the results of ophthalmologists Page 17 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 features to realize the distinction between more ophthalmologies and identify different disease categories. Abbreviations OCT: optical coherence tomography; BLS-GSM: Bayesian least squares–Gaussian scale mixture approaches; NL Means: non-local means; NCDF: nonlinear complex diffusion filter; CWDL: complex wavelet based dictionary learning methods; BM3D: block-matching and 3D filtering; CNR: contrast-to-noise ratio; TP: texture preservation; EP: edge preservation; ENL: equivalent number of looks; ILM: internal limiting membrane; RPE: retinal pigment epithelium; PA_L: left parafovea; PA_R: right parafovea; PE_L: left perifovea; PE_R: right perifovea; TR: thickness ratio. Authors’ contributions DF carried out the study design, the statistical analysis and drafted the manuscript. HT, SZ developed the algorithm, carried out the experiments and drafted the manuscript. LL, FG performed the acquisition of the OCT images and consulted the obtained results. JM helped in the results analysis and reviewed the manuscript. All authors read and approved the final manuscript. Author details 1 School of Automation and Electrical Engineering, University of Science and Technology Beijing, Xueyuan Road 30, Haidian District, Beijing, China. 2 The 306th Hospital of People’s Liberation Army, Beijing, China. 3 Dept. of Telecommunications, Faculty of Electrical Engineering and Communication, Brno University of Technology, Czech, Brno, Czech Republic. Acknowledgements This research is supported by the National Natural Science Foundation of China (No. 61272358). Competing interests The authors declare that they have no competing interests. Availability of data and supporting materials The raw image data and software are easy to use and available freely at https://zenodo.org/record/56515. The raw database includes 200 retinal OCT imagesjudged as normal by ophthalmologists and 100 images with various abnormalities.The software includes the main steps introduced in this paper and the four retinalOCT images for simulation. The software was carried out in Matlab. Received: 7 March 2016 Accepted: 10 July 2016 References 1. Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, Hee MR, Flotte T, Gregory K, Puliafito CA. Optical coherence tomography. Science. 1991;254(5035):1178–81. 2. Virgili G, Menchini F, Murro V, Peluso E, Rosa F, Casazza G. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy. Cochrane Database Syst Rev. 2011;7:CD008081. 3. Ouyang Y, Heussen FM, Hariri A, Keane PA, Sadda SR. Optical coherence tomography-based observation of the natural history of drusenoid lesion in eyes with dry age-related macular degeneration. Ophthalmology. 2013;120(12):2656–65. 4. Andreoli MT, Lim JI. Optical coherence tomography retinal thickness and volume measurements in X-linked retinoschisis. Am J Ophthalmol. 2014;158(3):567–73. 5. Roh YR, Park KH, Woo SJ. Foveal thickness between stratus and spectralis optical coherence tomography in retinal diseases. Korean J Ophthalmol. 2013;27(4):268–75. 6. Wolf-Schnurrbusch UE, Ceklic L, Brinkmann CK, Iliev ME, Frey M, Rothenbuehler SP, Enzmann V, Wolf S. Macular thickness measurements in healthy eyes using six different optical coherence tomography instruments. Invest Ophthalmol Vis Sci. 2009;50(7):3432–7. 7. Quellec G, Lee K, Dolejsi M, Garvin MK, Abramoff MD, Sonka M. Three-dimensional analysis of retinal layer texture: identification of fluid-filled regions in SD-OCT of the macula. IEEE Trans Med Imaging. 2010;29(6):1321–30. 8. Gregori G, Wang F, Rosenfeld PJ, Yehoshua Z, Gregori NZ, Lujan BJ, Puliafito CA, Feuer WJ. Spectral domain optical coherence tomography imaging of drusen in nonexudative age-related macular degeneration. Ophthalmology. 2011;118(7):1373–9. 9. Iwama D, Hangai M, Ooto S, Sakamoto A, Nakanishi H, Fujimura T, Domalpally A, Danis RP, Yoshimura N. Automated assessment of drusen using three-dimensional spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53(3):1576–83. 10. Chen Q, Leng T, Zheng L, Kutzscher L, Ma J, de Sisternes L, Rubin DL. Automated Drusen segmentation and quantification in SD-OCT images. Med Image Anal. 2013;17(8):1058–72. 11. Liu YY, Chen M, Ishikawa H, Wollstein G, Schuman JS, Rehg JM. Automated macular pathology diagnosis in retinal OCT images using multi-scale spatial pyramid and local binary patterns in texture and shape encoding. Med Image Anal. 2011;15(5):748–59. 12. Liu YY, Ishikawa H, Chen M, Wollstein G, Duker JS, Fujimoto JG, Schuman JS, Rehg JM. Computerized macular pathology diagnosis in spectral domain optical coherence tomography scans based on multiscale texture and shape features. Invest Ophthalmol Vis Sci. 2011;52(11):8316–22. Page 18 of 18 Fu et al. BioMed Eng OnLine (2016) 15:87 • We accept pre-submission inquiries • Our selector tool helps you to find the most relevant journal • We provide round the clock customer support • Convenient online submission • Thorough peer review • Inclusion in PubMed and all major indexing services • Maximum visibility for your research Submit your manuscript at www.biomedcentral.com/submit Submit your next manuscript to BioMed Central and we will help you at every step: 13. Koprowski R, Teper S, Wrobel Z, Wylegala E. Automatic analysis of selected choroidal diseases in OCT images of the eye fundus. Biomed Eng Online. 2013;12:117. 14. Koprowski R, Rzendkowski M, Wrobel Z. Automatic method of analysis of OCT images in assessing the severity degree of glaucoma and the visual field loss. BioMed Eng OnLine. 2014;13:16. 15. Xu J, Ishikawa H, Wollstein G, Bilonick RA, Folio LS, Nadler Z, Kagemann L, Schuman JS. Three-dimensional spectraldomain optical coherence tomography data analysis for glaucoma detection. PLoS One. 2013;8(2):e55476. 16. Hughes M, Spring M, Podoleanu A. Speckle noise reduction in optical coherence tomography of paint layers. Appl Opt. 2010;49(1):99–107. 17. Jorgensen TM, Thomadsen J, Christensen U, Soliman W, Sander B. Enhancing the signal-to-noise ratio in ophthalmic optical coherence tomography by image registration-method and clinical examples. J Biomed Opt. 2007;12(4):041208–10. 18. Portilla J, Strela V, Wainwright MJ, Simoncelli EP. Image denoising using scale mixtures of Gaussians in the Wavelet domain. IEEE Trans Image Process. 2003;12(11):1338–51. 19. Buades A, Coll B, Morel JM. A review of image denoising algorithms, with a new one. Siam J Multiscale Model Simul. 2005;4(2):490–530. 20. Bernardes R, Maduro C, Serranho P, Araujo A, Barbeiro S, Cunha-Vaz J. Improved adaptive complex diffusion despeckling filter. Opt Express. 2010;18(23):24048–59. 21. Dabov K, Foi A, Katkovnik V, Egiazarian K. Image denoising by sparse 3D transform-domain collaborative filtering. IEEE Trans Image Process. 2007;16(8):2080–95. 22. Duan J, Lu W, Tench C, et al. Denoising optical coherence tomography using second order total generalized variation decomposition. Biomed Signal Process Control. 2016;24:120–7. 23. Wong A, Mishra A, Bizheva K, Clausi DA. General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery. Opt Express. 2010;18(8):8338–52. 24. Kafieh R, Rabbani H, Selesnick I. Three dimensional data-driven multi scale atomic representation of optical coherence tomography. IEEE Trans Med Imaging. 2015;34(5):1042–62. 25. Mayer MA, Borsdorf A, Wagner M, Hornegger J, Mardin CY, Tornow RP. Wavelet denoising of multiframe optical coherence tomography data. Biomed Opt Express. 2012;3(3):572–89. 26. Kafieh R, Rabbani H, Abramoff MD, Sonka M. Curvature correction of retinal OCTs using graph-based geometry detection. Phys Med Biol. 2013;58(9):2925–38. 27. Pizurica A, Jovanov L, Huysmans B, et al. Multiresolution denoising for optical coherence tomography: a review and evaluation. Curr Med Imaging Rev. 2008;4(4):270–84. 28. Chiu SJ, Li XT, Nicholas P, Toth CA, Izatt JA, Farsiu S. Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation. Opt Express. 2010;18(18):19413–28. 29. Niu S, Chen Q, de Sisternes L, Rubin DL, Zhang W, Liu Q. Automated retinal layers segmentation in SD-OCT images using dual-gradient and spatial correlation smoothness constraint. Comput Biol Med. 2014;54:116–28. 30. Yazdanpanah A, Hamarneh G, Smith BR, Sarunic MV. Segmentation of intra-retinal layers from optical coherence tomography images using an active contour approach. IEEE Trans Med Imaging. 2011;30(2):484–96. 31. Lang A, Carass A, Hauser M, Sotirchos ES, Calabresi PA, Ying HS, Prince JL. Retinal layer segmentation of macular OCT images using boundary classification. Biomed Opt Express. 2013;4(7):1133–52. 32. Han JH, Cha YM. High-accuracy retinal layer segmentation for optical coherence tomography using tracking kernels based on Gaussian mixture model. IEEE J Sel Topics Quantum Electron. 2013;20(2):1–10. 33. Dufour PA, Ceklic L, Abdillahi H, Schroder S, De Dzanet S, Wolf-Schnurrbusch U, Kowal J. Graph-based multi-surface segmentation of OCT data using trained hard and soft constraints. IEEE Trans Med Imaging. 2013;32(3):531–43. 34. Song Q, Bai J, Garvin MK, Sonka M, Buatti JM, Wu X. Optimal multiple surface segmentation with shape and context priors. IEEE Trans Med Imaging. 2013;32(2):376–86. 35. Duan XR, Liang YB, Friedman DS, Sun LP, Wong TY, Tao QS, Bao L, Wang NL, Wang JJ. Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult Chinese persons: the Handan Eye Study. Ophthalmology. 2010;117(8):1585–94. 36. Shen L, Gao F, Xu X, Lin Z, Zhang Z, Zhao B, Zhang X, Li B, Jonas JB. Macular thickness in Chinese. Acta Ophthalmol. 2013;91(1):e77–9.