electronics Article Voltage H∞Control of a Vanadium Redox Flow Battery Alejandro Clemente 1,*, Germán Andrés Ramos 2and Ramon Costa-Castelló 1 1Institut de Robòtica i Informàtica Industrial, CSIC-UPC, Llorens i Artigas 4-6, 08028 Barcelona, Spain; [email protected] 2Department of Electrical and Electronic Engineering, Universidad Nacional de Colombia, Bogotá 111321, Colombia; [email protected] *Correspondence: alejandr[email protected] Received: 24 August 2020; Accepted: 21 September 2020; Published: 24 September 2020 Abstract: Redox flow batteries are one of the most relevant emerging large-scale energy storage technologies. Developing control methods for them is an open research topic; optimizing their operation is the main objective to be achieved. In this paper, a strategy that is based on regulating the output voltage is proposed. The proposed architecture reduces the number of required sensors. A rigorous design methodology that is based on linear H∞ synthesis is introduced. Finally, some simulations are presented in order to analyse the performance of the proposed control system. The results show that the obtained controller guaranties robust stability and performance, thus allowing the battery to operate over a wide range of operating conditions. Attending to the design specifications, the controlled voltage follows the reference with great accuracy and it quickly rejects the effect of sudden current changes. Keywords: energy storage systems; flow battery; vanadium redox flow battery; H∞ control; uncertainty models 1. Introduction It is a real fact that the use of renewable energy is growing more and more, due to its environmental benefits [ 1 ]. Mainly, these renewable energy sources (RES) are based on the use of solar, wind, or marine energy, between others. Because of their nature, RES are intermittent and the delivered power fluctuates in time, depending on non-controllable variables, such as the weather conditions. This results in the impossibility to satisfy the constant demand of energy. For that reason, trying to solve this problem, the use of energy storage systems (ESS) is having a great impact within the energy field [ 2 – 6 ]. There are different types of ESS according to the methodology used to convert and store the energy, which are mechanical, electrical, or electrochemical systems. Inside the group of electrochemical ESS, redox flow batteries (RFB) are being widely studied and used today. One of their main advantages, is the possibility to store large quantities of energy, which is why they are a great option for large-scale energy applications [ 7 , 8 ]. In addition, it is worth highlighting other characteristics, such as the modularity between power and energy, efficiencies in a range from 75% to 85% [ 9 ], and being a clean storage system without producing emissions of any kind into the atmosphere. For that reason, taking into account all of the advantages that RFB present, a lot of research is being carried out to improve the design of these systems. RFB consist on an electrochemical cell, where the energy is generated from a redox reaction that takes place inside the cell with different chemical components that are dissolved in liquids that are pumped from external tanks. Thereby, the energy is stored inside the tanks and, for that reason, Electronics 2020,9, 1567; doi:10.3390/electronics9101567 www.mdpi.com/journal/electronics
Electronics 2020,9, 1567 2 of 24 increasing the volume of the tanks allows for storing more energy, which makes the system suitable for large-scale applications. There exists different types of RFB systems depending on the components that take part in the redox reaction. Some common examples are the Fe-Cr RFB, which uses Fe(III) and Fe(II) as positive active components, and the species Cr(III) and Cr(II) as negative ones, dissolved in HCl [ 10 ]. The iron-chromium (I-Cr) and the zinc-bromide (Zn-Br) batteries are other examples [11,12]. During the last years, the vanadium redox flow battery (VRFB) is the one that has beeb studied and used the most. The main reason is its benefits as compared to other species, allowing for the possible mixture of species inside the cell without damaging or degrading the battery [ 13 ]. Redox flow batteries are currently been studied and most of the research is focused on an optimal design of the physical, in terms of the components and materials that comprise it. From an automatic control point of view, two main problems exist in VRFB [ 14 ]. The first one is determining the instantaneous reactant flow, which guarantees the desired output voltage in an efficient and secure manner. The second one is estimating the most relevant variables in the RFB, with the state of charge (SOC) being one of the most important ones. Having a model of the RFB is very important in both problems. The literature contains different RFB models. A three-dimensional (3D) model is presented in [ 15 ] in order to analyse the behaviour of the flow field inside all components of the system. It makes possible to analyse how the flow is distributed along the cells, obtaining a realistic approximation about the distribution of vanadium concentration inside of them. The use of lumped parameter models has been widely used with positive results. Some studies determine the behaviour of vanadium species through the redox reactions that take place inside the cell [ 16 , 17 ]. Another one takes into account the cell voltage in order to determine the concentration of species inside the cell [ 18 ]. Furthermore, there are studies that propose equivalent models that are based on electric circuits, composed by resistors and capacitors that allow for describing the capacity of the battery, which is transduced in the energy stored on it. This last approach is presented in [19,20]. RFB models are, in general, non-linear and they show an important coupling between most relevant variables such as voltage, current, SOC, and reactant flow. This makes the control design challenging. There are different studies that have been developed in order to establish a control strategy for a VRFB. A minimum flow rate strategy is presented in [ 21 , 22 ], which allows for guaranteeing the correct operation in both charging and discharging processes. The works in [ 23 – 25 ] present an optimal flow rate strategy that tries to maximize the efficiency of the battery taking internal losses into account. The above mentioned strategies can be considered open-loop techniques, i.e., the reactant flow is computed based on the model, the measured current, and the estimated SOC; and, in this way, the voltage is indirectly controlled. This makes that the voltage is not precisely regulated. Furthermore, the open-loop control systems are not robust, since they very sensitive to disturbances, parameters uncertainties, and non-modeled dynamics. Other studies have proposed the regulation of some variables, typically the stack voltage. In [ 26 ], a PI controller is proposed for regulating the output voltage. The controller is designed while using a linearized model. However, the closed-loop robustness and stability is not analysed. In [ 27 ], a gain scheduling strategy is proposed. Three operating points are selected to switch between different PI controllers. Although a bumpless transfer strategy is implemented, no formal stability analysis and the robustness analysis is performed. Other studies, such [ 28 ], present a controller that, in addition to output voltage, regulates the temperature of the complete system. In this paper, a voltage controller designing an H∞ framework is proposed. H∞ control has been used in different energy systems to handle uncertainty [ 29 , 30 ] while offering efficiency. Although the H∞ control theory could be directly applied to non-linear systems, constructive methods are applicable, above all, to linear systems. Due to this, in this work we take the original non-linear electrochemical model developed by Maria Skyllas-Kazacos [ 18 ] and linearise it around different equilibrium points. The different linear models will then be combined in a new linear system with
Electronics 2020,9, 1567 3 of 24 uncertainty. The uncertainty will represent the variation of the linearised models when the equilibrium point changes. A large set of linear systems has been used to widen the operational range of the controller. As a result, a voltage controller that guarantees the closed-loop stability and performance in all equilibrium points will be obtained. Robustness and performance are considered in the design and these characteristics can be tuned by the designer. Moreover, the developed control system is robust in front of possible uncertainty in the current or sudden changes in its value, allowing for delivering the power that is desired by the user in this possible scenario. The main novelty of this work is introducing a constructive and formal methodology to design a voltage controller for VRFB. Differently from previous works, the proposed approach guarantees closed-loop performance in all operation space using only the voltage measurement. This work has been organized, as follows: Section 2describes the used VRFB model; Section 3 contains an analysis of the system equilibrium points; Section 4describes the controller specification and design; Section 5contains different simulation results; and finally, Section 6contains some conclusions and future works. 2. System Modeling 2.1. Operation of a VRFB Figure 1shows the conventional scheme of a RFB; it is composed by two tanks containing the electrolytes dissolved in solutions. These electrolytes are pumped by two coordinated pumps through a cell stack. It is in this cell where the oxidation reduction reaction (REDOX) and the electric current is absorbed or generated. The electrolytes return to the tanks with a different concentration of species from the initial one. The species concentration in the tanks is directly related with the stored energy, i.e., the state of charge (SOC); while, the species concentration in the cell is directly related with the output voltage. Figure 1. Scheme of a redox flow battery. In a VRFB, the electrolytes contain salts of vanadium dissolved in solutions of sulphuric acid. In this case, all of the species are vanadium in different oxidation states (+II, +III, +IV, +V). The anolyte is composed by V2+ and V3+ vanadium species, while the catholyte is composed by V4+ and V5+ . It is important to notice that the vanadium species V4+ and V5+ exist as oxides, which are VO2+ and VO+ 2, respectively.
Electronics 2020,9, 1567 4 of 24 During the charging process, V4+ oxidizes to V5+ , releasing an electron, which is transferred from the cathode to the anode, reducing V3+to V2+. The total reaction can be written as V2+→V3++e− VO+ 2+2H++e−→VO2++H2O(1) The process occurs in the reverse direction during the discharge. Subsequently, it is possible to conclude that, depending on the amount of electrons that appear on the cell in a discharging or charging process, the concentration of each specie will vary according to the reaction that is presented in (1). The voltage in the cell can be computed while using the Nerst equation. This allows to know which is the electrode potential that appears in the extremes of a cell while taking the different concentrations of vanadium species contained on it into account. The electrode potential E has the following expression [31]: E=Eθ+RT Fln ccell 5 ccell 4!catholyte ccell 2 ccell 3!anolyte , (2) where R and F are, respectively, the gas and Faraday constant, T is the temperature, Eθ is the standard electrode potential, and ccell iis the concentration of vanadium specie iin the cell. Experimentally, it has been found that the maximum value of the cell voltage during the charging process varies between 1.6 and 1.7 V, and then drops to 1.1 V during discharging [ 31 , 32 ]. As this value is low, in order to increase the voltage, different cells are connected in series, defining what is usually known as a stack. The RFB state of charge (SOC), which corresponds the amount of energy that is stored in the tanks, can be computed as a function of the vanadium species contained in the tank as: SOC = ctank 2 ctank 2+ctank 3!= ctank 5 ctank 4+ctank 5!(3) where ctank i is the concentration of vanadium specie i in the tank. The index i= 2 corresponds to V2+ , i= 3 to V3+ , i= 4 to V4+ (which exists as VO2+ ) and i= 5 (which exists as VO+ 2 ). This same convention is used in the cell concentration. 2.2. VRFB Electrochemical Model One of the most popular models for describing the electrochemical behaviour was introduced by Maria Skyllas-Kazacos [ 18 ]. It allows for describing the evolution of the vanadium species concentrations, both in the tanks and the cells and it has been experimentally validated with excellent results [18,25]. The equation describing the evolution of the vanadium species concentrations in the cell is given by: Vcell 2˙ xcell =xtank −xcellqcell +1 zF 1 −1 −1 1 icell +S d −k20−k4−2·k5 0−k32·k43·k5 3·k22·k3−·k40 −2·k2−k30−k5 xcell, (4) where xcell =hccell 2,ccell 3,ccell 4,ccell 5iT , xtank =hctank 2,ctank 3,ctank 4,ctank 5iT , Vcell is the volume of the cell, qcell is the electrolyte flow rate, icell is the current in the cell (positive and negative currents define the charging and discharging process, respectively), z is the number of electrons that are involved in the
Electronics 2020,9, 1567 5 of 24 reaction ( z= 1), S is the surface and d the thickness of the membrane, and finally, ki is the diffusion coefficient for vanadium specie i. Equation (4) can be rewritten in a more compact form as: ˙ xcell =fcell xcell,xtank,icell,qcell. (5) The equation describing the tank concentration considering the number of cells that compose the stack is: Vtank ˙ xtank =Nxcell −xtankqcell, (6) where Vtank is the volume of each electrolyte tank and N is the number of cells that compose the stack. Equations (5) and (6) define a dynamical system that describes the electrochemical behaviour in the RFB. In this model, xcell and xtank are the state variables and and qcell and icell are two exogenous variables. From a control perspective, qcell is usually assumed as the control action, while icell is considered to be a measurable disturbance. In this work, a 3 kW and 15 kWh VRFB system has been considered with a total vanadium concentration of 2 M for each couple of species. The other parameters that are needed to obtain the model are summarized in Tables 1and 2. Table 1. Parameters and constants for Nerst Equation. Parameter Meaning Unit—Value ccell iConcentration of specie i inside the cell mol·m−3 EElectrode potential V EθStandard potential 1.259 V TTemperature of the cell K FFaraday’s constant 96,485 C·mol−1 RGas constant 8.314 J·K−1·mol−1 Table 2. Parameters of the electrochemical model [18]. Parameter Meaning Unit—Value Vcell Volume of the cell 9.5·10−4m3 Vtank Volume of each tank 0.4 m3 QFlow rate m3·s−1 ICurrent A SSurface area of the electrode 0.15 m2 dMembrane thickness 1.27·10−4m k2Diffusion coefficient of V2+8.768·10−12 m·s−1 k3Diffusion coefficient of V3+3.221·10−12 m·s−1 k4Diffusion coefficient of V4+6.825·10−12 m·s−1 k5Diffusion coefficient of V5+5.896·10−12 m·s−1 NNumber of cells of the stack 19 3. Equilibrium Points Analysis Equilibrium points play a very important role in dynamical systems [ 33 , 34 ]. These points correspond to the configurations (values of the state variables) where the dynamic system can remain stationary, due to this they are also called operation points. The equilibrium points are the solutions that make the derivatives of the differential equations of a system equal to zero. To compute the equilibrium points for the dynamic system defined by (5) and (6), it is necessary to force ˙ xcell = 0 and ˙ xtank = 0 and isolate the value of xcell and xtank . Because (5) and (6) depend on icell and qcell , there is no solution, but icell = 0, qcell = 0, xcell = 0, and xtank = 0, which is clearly not of interest. In RFB, the volume of the tanks, Vtank , is much bigger than the volume of the cell, Vcell , and, consequently, the variation of xtank is tiny in comparison to the variation of xcell . Therefore,
Electronics 2020,9, 1567 6 of 24 a natural assumption is to assume that ˙ xtank ≈ 0, which implies that xtank is constant, i.e., SOC is constant. Under this assumption, the equilibrium points of (5) can be found. These equilibrium points will depend on the value of xtank, i.e., the SOC, icell and qcell. From the analysis of these points, it is possible to determine which is the optimal qcell , once the SOC and icell have been fixed. Figures 2and 3show the values of V2+ and V3+ in the cell for a 10% of SOC, a different values of icell , from 10 to 140 A, and qcell from 75 mL/s to 800 mL/s [ 26 , 35 , 36 ]. Figures 2and 3are representative of a charging procedure. Figure 2. Equilibrium points of V2+for a 10% of state of charge (SOC). Figure 3. Equilibrium points of V3+for a 10% of SOC. Becasue the total vanadium concentration is 2000 mol/ m 3 , the vanadium concentration in the cell is limited to this value. For a 10% of SOC, the concentration in the anolyte tank corresponds to 200 mol/m3for V2+and 1800 mol/m3for V3+. Looking at Figures 2and 3, it can be observed that the surface stay as an horizontal plane at the majority of current and flow points. This behaviour is observed, especially at flow rates that are greater than 0.2 L / s. This means that concentration in the cell is almost the same in the tank for high flow rates. In the case of V2+is 200 mol/m3, and for V3+is 1800 mol/m3. However, at a low enough flow rate, the surface is heading upwards for the more negative specie, which is V2+ , and downwards for the more positively charged V3+ . This behaviour can be better appreciated as the current increases, reaching the corresponding maximum or minimum at the lowest flow with the highest current.
Electronics 2020,9, 1567 7 of 24 When the RFB is charging, introducing a certain positive current, the more positively charged ion, which is V3+ , is reduced by the corresponding electrons of the current, which convert them to their counterpart, the more negatively charged ions V2+. When the flow is lower, more time is necessary in order to take the ions in the cell to get out of it. In terms of current, as it increases, a faster reduction happens. When both circumstances happen, the reduced ions begin to build up on the cell itself, which is why that upwards tilting begins to happen with vanadium specie V2+ . In counterpart, the vanadium concentration of ions V3+ decreases with a behavior that is contrary to that of V2+. Figures 4and 5show the values of V2+ and V3+ in the cell for an 80% of SOC, which implies having 1600 mol/ m 3 of V2+ specie, and 400 mol/ m 3V2+ inside the tank. In this new situation, the surface gets to his maximum possible concentration for V2+ , which is 2000 mol/ m 3 , and the minimum, which is 0 mol/ m 3 for V3+ specie. This maximum value can be observed in Figure 4, which is represented in yellow. On the other case, the minimum concentration of 0 mol/m 3 is observed in dark blue in Figure 5. Figure 4. Equilibrium points of V2+for an 80% of SOC. Figure 5. Equilibrium points of V3+for an 80% of SOC. With these studies, it is possible to characterize the stationary behavior of the different concentrations and, therefore, of the voltage in the cell. The behavior has been analyzed for a loading and unloading scenario, but it is possible to do it for other SOC values. The behavior evolves smoothly between the two examples presented.
Electronics 2020,9, 1567 8 of 24 4. Controller Design 4.1. Introduction Differently from other types of batteries, like Li-on, RFB are active elements, i.e., it is necessary to feed the cell with reactants. Because of this, it is necessary to design a control system that guarantees the correct closed-loop behavior. The RFB has two inputs, the current, icell , and the flow rate, qcell , as discussed in Section 2. From a control point of view, icell is treated as measurable disturbance, while qcell is used as control action. A very relevant measurable variable is the output voltage, E . The voltage combined with the current determine the input/output power. In this section, a voltage controller will be designed. The methodology that is used to design the controller is based on the H∞ control theory, which allows for synthesizing controllers that guarantee performance specifications and, at the same time, achieve the stabilization of the system. Linear H∞ methods [ 37 ] are used to shape the frequency response of the most relevant closed-loop transfer functions in a control system. This shaping is formulated as an optimization problem in terms of the infinity norm: || · ||∞ . The procedure to design a controller is based on two steps; in the first one, the specifications are defined through the use of weighting functions that can be understood as bounds over the frequency response. Once the specifications are made, the optimal controller is obtained, i.e., the controller is the one that better fulfils the specifications in terms of the || · ||∞ . One of the main advantages of the H∞ design method is that it permits dealing with model and parametric uncertainties. In this way, we can design controllers that preserve closed-loop stability and desired performance in spite of plant uncertainties. These characteristics can be applied in order to design the control system of the redox battery. In this case, with the distinct equilibrium points of the system, we can create a structure for the plant composed of a nominal model of the battery that is associated to a norm-bounded uncertainty. On this base, the H∞ design is used to accomplish closed-loop stability and performance in a wide range of operating conditions. 4.2. Model Simplification Before designing the controller, the plant model (5) will be simplified. To do so, the following assumptions can be made: • Vanadium concentrations are the same on both sides of the half cell. Therefore, it is possible to have the following correspondence: ccell 2=ccell 5ccell 3=ccell 4 • The tanks concentration can be expressed in terms of SOC and total vanadium concentration cv: ctank 2=cvSOC ctank 3=cv·(1−SOC) Taking into account these equalities, it is possible to express the electrochemical model, reducing Equations (4) and (2) to: Vcell d dt "ccell 2 ccell 3#="cv·SOC −ccell 2 cv·(1−SOC)−ccell 3#qcell + 1 F −1 F!icell +S d −k2−2k5−k4 3k5−k3+2k4!"ccell 2 ccell 3#(7) E=Eθ+2NRT Fln ccell 2 ccell 3!, (8) respectively.
Electronics 2020,9, 1567 9 of 24 4.3. System Linearization The system that is defined by (7) and (8) can be easily transformed in the standard nonlinear state space form: ˙x=f(x,u) y=h(x,u) with y=E , x=hccell 2,ccell 3iT and u=hicell,qcelliT . This model can be linearized around its equilibrium points (¯x,¯ u), using the Taylor series, as follows: f(x,u) = f(¯x,¯ u) + ∂f ∂x¯x,¯ u ∆x+∂f ∂u¯x,¯ u ∆u+h.o.t(∆x,∆u) h(x,u) = h(¯x,¯ u) + ∂h ∂x¯x,¯ u ∆x+∂h ∂u¯x,¯ u ∆u+h.o.t(∆x,∆u) where h . o . t denotes high order terms, which will be very close to zero if states ( x , u ) are sufficiently close to its equilibrium points (¯x,¯ u). It is possible to rewrite the linearized system in the state space form, as follows: ˙ ∆x=A∆x+b∆u ∆y=c∆x+d∆u where ∆x=x−¯x,∆u=u−¯ u, and ∆y=y−¯ y, and A,b,c,dare the following jacobian matrices: A=∂f ∂x¯x,¯u b=∂f ∂u¯x,¯u c=∂h ∂x¯x,¯u d=∂h ∂u¯x,¯u For the system that is defined by (7) and (8), the Jacobian matrices become: A=1 Vcell "S d(−k2−2k5)−¯ qcell S d(−k4) S d(3k5)S d(k4−k3)−¯ qcell#(9) b=1 Vcell "cvSOC −¯ ccell 2 cv(1−SOC)−¯ ccell 3#(10) c=h2NRT F·1 ¯ ccell 2 −2NRT F·1 ¯ ccell 3i(11) d=0 (12) The system defined by (A , b , c , d) allows for analyzing the nonlinear system behavior around the equilibrium point. 4.4. Uncertainty Modeling The values (A , b , c , d) defined by (9)–(12) depend on the value of different parameters, the value of the SOC, and the concrete equilibrium point. Figure 6shows the frequency response of different linear plants obtained sweeping the value of SOC between 10% to 90%, which corresponds to almost a full charged or discharged VRFB and sweeping the current value from 15 to 120 A (for both charging and discharging modes). Similarly, Figure 7shows the step response of these linear models. As it can be seen, there is an important variability in both gain and time constant. It is important to take this variability in the controller design into account. A model with uncertainty will be developed in order to design a controller that can operate while taking into account all possible range of operation of SOC, current, and flow rate.
Electronics 2020,9, 1567 16 of 24 10-7 10-6 10-5 10-4 10-3 10 -2 10-1 0 0.2 0.4 0.6 0.8 1 1.2 Robust performance test Figure 16. Formal robust performance analysis for the reduced order controller, ¯ C(s). 4.6. Integral Controller Design It is well-known that integral action guarantees null steady-state error for constant or piecewise constant references. Unfortunately, H∞ control does not generate controllers with integral action in general. In order to eliminate the error against step-type reference changes, an integral part can be applied to the designed controller. To force the appearance of an integral action in the controller, while preserving the nice properties of the H∞ framework, the weighting function for the nominal sensitivity function has been modified as: W0 e(s) = We(s)·s+K·e0 s+e0(18) where e0 must take the lowest possible value and K the highest one. Under these conditions, the dc gain of W0 e(s) , will be K/e . Consequently, an effect that is similar to placing a zero at s= 0 in W0 e(s) will be achieved. This will force |W0 e(jω)| to be very high in the very low frequency range while preserving the frequency response of the original weighting function in the other frequencies. Ideally, e0 should be practically zero, but computationally it is not possible to do so. In this work, after some numerical testing, K= 10 3 and e0= 10 −10 have been selected. Figure 17 shows a comparison between the bounds imposed by the original, We(s) , and the new, W0 e(s) , weighting functions. As it can be seen, they are almost the same, but in the very low frequency range where W0 e(s)imposes harder constrains. Once the weighting function has been redefined, the optimal controller is obtained again. Previous manipulations will force that the controller has a pole close to the origin. This pole is latter manually replaced by an integrator. This will generate an order 7 controller, Ci(s) . Note that, as the weighting function has increased its order, the controller also increased the order. This controller makes that W0 e(s)Si,n(s) Wa u(s)Ci(s)Si,n(s) =0.8605 which is small than 1, this implies that this controller guarantees both NP and RS. As in the previous section, the order of this controller can be reduced up to order two, ¯ Ci(s). This controller can be rewritten as the Proportional, Integral, and Derivative (PID) one: PID(s) = ¯ Ci(s) = kp+ki s+kds τs+1(19) with kp=− 3.7053 · 10 −5 , ki=− 6.7840 · 10 −8 , kd= 0.0679 and τ= 10 6 . The PID Controller will be easier to implement on most platforms.
Electronics 2020,9, 1567 17 of 24 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 -120 -100 -80 -60 -40 -20 0 20 Magnitude (dB) Bode Diagram Frequency (rad/s) Figure 17. Comparison between the two weighing function, 1 /We(s) and 1 /W0 e(s) frequency responses. Figure 18 shows an informal proof of the RP condition. As it can be seen, all selected plants fulfil the specifications, which point up that the RP might be fulfilled. Figure 19 contains a formal analysis of the RP condition. The RP condition is not formally fulfilled, but it holds in almost all frequencies, which can be considered good enough from a practical point of view, as it can be observed. Finally, Figure 20 contains the step response of a number of plants, as it can be seen in all cases that a smooth response is obtained with null steady-state error. 10-12 10-10 10-8 10-6 10-4 10-2 -160 -140 -120 -100 -80 -60 -40 -20 0 Magnitude (dB) Robust Performance Frequency (rad/s) Figure 18. Approximated robust performance check for the closed-loop system step response with ¯ Ci(s)and W0 e(s).
Electronics 2020,9, 1567 18 of 24 10-12 10-10 10-8 10-6 10-4 10-2 0 0.2 0.4 0.6 0.8 1 Robust performance test Figure 19. Formal robust performance check for the closed-loop system step response with ¯ Ci(s) and W0 e(s). Figure 20. Closed-loop system step response with ¯ Ci(s). 4.7. Materials and Methods The controller design procedure is one important result of this work. Figure 21 shows flowchart which summarizes the methodology introduced in previous subsections. Once the detailed non-linear model is defined, the design starts with the equilibrium point analysis. From this analysis, a set of representative operation points is selected, in each of these points the non-linear system is linearised; consequently, a set of linear models which cover the operation space is obtained. From this set of plants, a nominal plant, Gn(s) , with additive uncertainty, Wa u(s) , is defined. At this point, the original non-linear system has been transformed into a linear system with uncertainty; consequently, linear techniques can be applied.
Electronics 2020,9, 1567 19 of 24 Nonlinear model equilibrium points analysis Set of linear plants Stablishment of nominal plant + uncertainity Start Performance especification Augmented plant definition Weighting function definition Controller synthesis based on the optimization NP, RS conditions Steady State Performance Operating range End Hold Satisfactory No hold No 1 1 3 2 2 2 wewu a Satisfactory Satisfactory No Satisfactory 3 Figure 21. Proposed method to obtain a satisfactory robust controller design. At this point, the closed-loop specifications are defined through a weighting function, We(s) , which define bounds over the closed-loop tracking error and the frequency response. Combining Gn(s) , Wa u(s) and We(s) , an augmented plant is built. Based on the augmented plant, the controller is synthesized using numerical methods. Once the controller is obtained, NP, RS and RP needs to be checked. If the specifications are meet, then a simulation against the original non-linear model is performed in order to guarantee the closed-loop behaviour, even for big movements (small movements around operation pints are constructively guaranteed). In case a wider operational range is needed, a larger set of linearised plant should be defined. The method should be iterated until all requirements are satisfactorily accomplished. 5. Results and Discussion This section will show the results that were obtained using the controller proposed in Section 4.6. The controller will be validated using the complete non-linear model presented in Section 2. This model has been previously experimentally validated in the literature and it precisely reproduces the reality [18,25]. Figure 22 shows the simulation block scheme. + − Figure 22. Closed-loop nonlinear simulation block scheme. As the stack is composed by 19 cells, according to the Nerst equation, during the charging process, the voltage values might vary in a range between 26 to 31 V approximately (see Figure 23).
Electronics 2020,9, 1567 20 of 24 Therefore, to analyse the behaviour of the controlled system, the voltage will be asked to follow a given voltage profile that is composed by different constant voltages. At the same time, it is important to study whether the controller is capable of operating under different current values. In this manner, uncertainty and disturbances are introduced in the system in terms of current. Hence, the current has been changed from 20 to 100 A in order to cover the full range. Figure 24 shows the profile of the current changes. 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Time (s) 26 26.5 27 27.5 28 28.5 29 29.5 30 Stack voltage (V) Stack voltage controlled Reference Voltage Figure 23. Stack voltage profile during the simulation. 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Time (s) 10 20 30 40 50 60 70 80 90 100 Stack Current (A) Current evolution Figure 24. Current profile during the simulation. Figure 23 shows how the voltage tracks the voltage reference when using the low-order controller with integral part. As it can be seen, the stack voltage follows the reference with great precision. The steady-state error is 0 and the disturbances due to the current variations are successfully rejected. The transient response is satisfactory, even when voltage and current change simultaneously. This confirms that the robust designed controller behaves correctly against current and voltage variations. Figure 25 shows the evolution of the flow rate generated by the proposed controller. As the flow rate is the control action, it is important to keep it bounded. With the defined operating conditions, it can be observed that the flow rate remains under 0.12 mL/s. Larger peaks in flow rate can be seen
Electronics 2020,9, 1567 21 of 24 when voltage and current change simultaneously; however, the maximum level of the control action (4.5 ×10−5m−3/s) is not reached. 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Time (s) 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Flow rate (m3/s) 10-5 Flow rate Figure 25. Flow rate profile during the simulation. It is important to note that neither current nor SOC are measured, only the voltage that is generated is used as the feedback signal. However, it is important to observe the evolution of the SOC. Figure 26 depicts the SOC against time for the given voltage and current profiles. Because current is always positive, the SOC is always increasing; this reflects the charging process of the VRFB. 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Time (s) 0.1 0.12 0.14 0.16 0.18 0.2 0.22 0.24 0.26 0.28 State of Charge (SOC) SOC monitoring Figure 26. SOC profile during the simulation. Finally, it can be seen that, with the designed robust controller, the VRFB works as expected, preserving the stability and performance. Furthermore, the specifications are kept under the operating conditions that are defined by current, flow rate, and SOC, which demonstrates that the controller successfully deals with uncertainty and disturbances. 6. Conclusions and Future Work In this paper, a methodology to design robust feedback controllers to regulate the RFB voltage has been presented. The proposed methodology is based on linear H∞ theory and it offers excellent performance in a wide range of operation points. The methodology offers a constructive and rigorous framework to design controllers for this type of system. Different from other controllers that were
Electronics 2020,9, 1567 22 of 24 previously proposed in the literature, this controller only uses the output voltage and it is very simple. Furthermore, it is demonstrated that the low order controller has the structure of a PID compensator. The low order controller has the advantage of easier implementation that requires lower computational burden. Currently, work is being done on the incorporation of current/SOC information in order to work at constant power or obtain a specific impedance. Another important line of work corresponds to the search for controllers that allow guaranteeing a long lifetime, by minimizing the system degradation, offering the desired performance at all operating points. Author Contributions: Conceptualization, R.C.-C. and A.C.; methodology, R.C.-C., A.C. and G.A.R.; software, A.C.; validation, G.A.R. and A.C.; investigation, R.C.-C. and A.C.; writing—original draft preparation, A.C.; writing—review and editing, G.A.R. and R.C.-C.; visualization, A.C.; supervision, R.C.-C.; project administration, R.C.-C.; funding acquisition, R.C.-C. All authors have read and agreed to the published version of the manuscript. Funding: This research was funded by the CSIC under the PTI FLOWBAT 2021 project (reference: 642 201980E101), the Spanish Ministry of Economy and Competitiveness under Project DOVELAR ref. RTI2018-096001-B-C32 (MCIU/AEI/FEDER, UE), María de Maeztu Seal of Excellence to IRI (MDM-2016-0656), and by the Generalitat de Catalunya through the Project 2017 SGR 482. Conflicts of Interest: The authors declare no conflict of interest. Abbreviations The following abbreviations are used in this manuscript: ESS Energy storage systems NP Nominal performance OCV Open circuit voltage RES Renowable energy sources RFB Redox flow battery RP Robust performance RS Robust stability SOC State of charge VRFB Vanadium redox flow battery References 1. Gielen, D.; Boshell, F.; Saygin, D.; Bazilian, M.D.; Wagner, N.; Gorini, R. The role of renewable energy in the global energy transformation. Energy Strateg. Rev. 2019,24, 38–50. [CrossRef] 2. Peker, M.; Kocaman, A.S.; Kara, B.Y. Benefits of transmission switching and energy storage in power systems with high renewable energy penetration. Appl. Energies 2018,228, 1182–1197. [CrossRef] 3. Root, C.; Presume, H.; Proudfoot, D.; Willis, L.; Masiello, R. Using battery energy storage to reduce renewable resource curtailment. IEEE Power Energy ISGTC 2017,1, 1–5. [CrossRef] 4. Nair, U.R.; Costa-Castelló, R. A Model Predictive Control-Based Energy Management Scheme for Hybrid Storage System in Islanded Microgrids. IEEE Access 2020,8, 97809–97822. [CrossRef] 5. Cecilia, A.; Carroquino, J.; Roda, V.; Costa-Castelló, R.; Barreras, F. Optimal Energy Management in a Standalone Microgrid, with Photovoltaic Generation, Short-Term Storage, and Hydrogen Production. Energies 2020,13, 1454. [CrossRef] 6. Bordons, C.; Garcia-Torres, F.; Ridao, M. Model predictive control of interconnected microgrids and with electric vehicles. Rev. Iberoam. Autom. Inform. Ind. 2020,17, 239–253. [CrossRef] 7. Shigematsu, T. Redox flow battery for energy storage. SEI Tech. Rev. 2011,73, 4–13. 8. Alotto, P.; Guarnieri, M.; Moro, F.; Stella, A. Redox Flow Batteries for large scale energy storage. In Proceedings of the 2012 IEEE International Energy Conference and Exhibition (ENERGYCON), Florence, Italy, 9–12 September 2012; Volume 1, pp. 293–298. [CrossRef] 9. Fujimoto, C.; Kim, S.; Stains, R.; Wei, X.; Li, L.; Yang, Z.G. Vanadium redox flow battery efficiency and durability studies of sulfonated Diels Alder poly(phenylene)s. Electrochem. Commun. 2012 ,20, 48–51. [CrossRef]
Electronics 2020,9, 1567 23 of 24 10. Zhang, D.; Liu, Q.; Li, Y. Chapter 3—Design of flow battery. In Reactor and Process Design in Sustainable Energy Technology; Elsevier: Amsterdam, The Netherlands, 2014; pp. 61–97. [CrossRef] 11. Zeng, Y.; Zhou, X.; An, L.; Wei, L.; Zhao, T. A high-performance flow-field structured iron-chromium redox flow battery. J. Power Sources 2016,324, 738–744. [CrossRef] 12. Suresh, S.; Kesavan, T.; Yeddala, M.; Arulraj, I.; Dheenadayalan, S.; Ragupathy, P. Zinc-bromine hybrid flow battery: Effect of zinc utilization and performance characteristics. RSC Adv. 2014,4. [CrossRef] 13. Chen, R.; Kim, S.; Chang, Z. Redox Flow Batteries: Fundamentals and Applications; IntechOpen: London, UK, 2017. [CrossRef] 14. Clemente, A.; Costa-Castelló, R. Redox Flow Batteries: A Literature Review Oriented to Automatic Control. Energies 2020,13. [CrossRef] 15. Messaggi, M.; Canzi, P.; Mereu, R.; Baricci, A.; Inzoli, F.; Casalegno, A.; Zago, M. Analysis of flow field design on vanadium redox flow battery performance: Development of 3D computational fluid dynamic model and experimental validation. Appl. Energy 2018,228, 1057–1070. [CrossRef] 16. Barton, J.L.; Brushett, F.R. A One-Dimensional Stack Model for Redox Flow Battery Analysis and Operation. Batteries 2019,5. [CrossRef] 17. Tang, A.; McCann, J.; Bao, J.; Skyllas-Kazacos, M. Investigation of the effect of shunt current on battery efficiency and stack temperature in vanadium redox flow battery. J. Power Sources 2013 ,242, 349–356. [CrossRef] 18. Wei, Z.; Xiong, R.; Lim, T.M.; Meng, S.; Skyllas-Kazacos, M. Online monitoring of state of charge and capacity loss for vanadium redox flow battery based on autoregressive exogenous modeling. J. Power Sources 2018,402, 252–262. [CrossRef] 19. Challapuram, Y.R.; Quintero, G.M.; Bayne, S.B.; Subburaj, A.S.; Harral, M.A. Electrical Equivalent Model of Vanadium Redox Flow Battery. In Proceedings of the 2019 IEEE Green Technologies Conference (GreenTech), Lafayette, LA, USA, 3–6 April 2019; pp. 1–4. [CrossRef] 20. Han, D.; Yoo, K.; Lee, P.; Kim, S.; Kim, S.; Kim, J. Equivalent Circuit Model Considering Self-discharge for SOC Estimation of Vanadium Redox Flow Battery. In Proceedings of the 2018 21st International Conference on Electrical Machines and Systems (ICEMS), Jeju, Korea, 7–10 October 2018; pp. 2171–2176. [CrossRef] 21. Blanc, C. Modeling of a Vanadium Redox Flow Battery Electricity Storage System; EPFL: Lausanne, Switzerland, 2009. [CrossRef] 22. Ma, X.; Zhang, H.; Sun, C.; Zou, Y.; Zhang, T. An optimal strategy of electrolyte flow rate for vanadium redox flow battery. J. Power Sources 2012,203, 153–158. [CrossRef] 23. Trovò, A.; Picano, F.; Guarnieri, M. Maximizing Vanadium Redox Flow Battery Efficiency: Strategies of Flow Rate Control. In Proceedings of the 2019 IEEE 28th International Symposium on Industrial Electronics (ISIE), Vancouver, BC, Canada, 12–14 June 2019; pp. 1977–1982. [CrossRef] 24. Houser, J.; Pezeshki, A.; Clement, J.T.; Aaron, D.; Mench, M.M. Architecture for improved mass transport and system performance in redox flow batteries. J. Power Sources 2017,351, 96–105. [CrossRef] 25. Tang, A.; Bao, J.; Skyllas-Kazacos, M. Studies on pressure losses and flow rate optimization in vanadium redox flow battery. J. Power Sources 2014,248, 154–162. [CrossRef] 26. Pugach, M.; Parsegov, S.; Gryazina, E.; Bischi, A. Output feedback control of electrolyte flow rate for Vanadium Redox Flow Batteries. J. Power Sources 2020,455, 227916. [CrossRef] 27. Li, Y.; Zhang, X.; Bao, J.; Skyllas-Kazacos, M. Control of electrolyte flow rate for the vanadium redox flow battery by gain scheduling. J. Energy Storage 2017,14, 125–133. [CrossRef] 28. Bhattacharjee, A.; Saha, H. Development of an efficient thermal management system for Vanadium Redox Flow Battery under different charge-discharge conditions. Appl. Energy 2018,230, 1182–1192. [CrossRef] 29. Bueno-Contreras, H.; Ramos Fuentes, G.A.; Costa Castelló, R. Robust H∞ Design for Resonant Control in a CVCF Inverter Application over Load Uncertainties. Electronics 2020,9. [CrossRef] 30. Ramos, G.A.; Ruget, R.I.; Costa Castelló, R. Robust Repetitive Control of Power Inverters for Standalone Operation in DG Systems. IEEE Trans. Energy Convers. 2020,35, 237–247. [CrossRef] 31. Knehr, K.; Kumbur, E. Open circuit voltage of vanadium redox flow batteries: Discrepancy between models and experiments. Electrochem. Commun. 2011,13, 342–345. [CrossRef] 32. Roznyatovskaya, N.; Noack, J.; Mild, H.; Fühl, M.; Fischer, P.; Pinkwart, K.; Tübke, J.; Skyllas-Kazacos, M. Vanadium Electrolyte for All-Vanadium Redox-Flow Batteries: The Effect of the Counter Ion. Batteries 2019,5, 13. [CrossRef]
Electronics 2020,9, 1567 24 of 24 33. Khalil, H.K. Nonlinear Systems, 3rd ed.; Prentice-Hall: Upper Saddle River, NJ, USA, 2002. 34. Slotine, J.; Li, W. Applied Nonlinear Control; Prentice-Hall: Englewood Cliffs, NJ, USA, 1991. 35. Zhang, B.; Lei, Y.; Bai, B.; Zhao, T. A two-dimensional model for the design of flow fields in vanadium redox flow batteries. Int. J. Heat Mass Transf. 2019,135, 460–469. [CrossRef] 36. Xiong, B.; Zhao, J.; Li, J. Modeling of an all-vanadium redox flow battery and optimization of flow rates. In Proceedings of the 2013 IEEE Power & Energy Society General Meeting, Vancouver, BC, Canada, 21–25 July 2013; pp. 1–5. 37. Sánchez-Peña, R.S.; Sznaier, M. Robust Systems Theory and Applications; Adaptive and Learning Systems for Signal Processing, Communications and Control Series; Wiley-Interscience: Hoboken, NJ, USA, 1998. 38. Balas, G.; Chiang, R.; Packard, A.; Safonov, M. Robust Control ToolboxTM User’s Guide; The MathWorks: Natick, MA, USA, 2019. © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).