Study of ionization charge density-induced gain suppression in LGADs

Jiménez-Ramos, M. C.,García López, J.,García-Osuna, Adrián,Vila, Iván,Currás, Esteban,Jaramillo, R.,Hidalgo, Salvador,Pellegrini, Giulio

Abstract

This article belongs to the Section Physical Sensors.

Full text

  Citation: Jiménez-Ramos, M.C.; García López, J.; García Osuna, A.; Vila, I.; Currás, E.; Jaramillo, R.; Hidalgo, S.; Pellegrini, G. Study of Ionization Charge Density-Induced Gain Suppression in LGADs. Sensors 2022,22, 1080. https://doi.org/ 10.3390/s22031080 Academic Editor: Francesco Della Corte Received: 9 December 2021 Accepted: 27 January 2022 Published: 30 January 2022 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). sensors Article Study of Ionization Charge Density-Induced Gain Suppression in LGADs M. Carmen Jiménez-Ramos 1,2,* , Javier García López 1,3, Adrián García Osuna 1, Iván Vila 4, Esteban Currás5, Richard Jaramillo 4, Salvador Hidalgo 6and Giulio Pellegrini 6 1Centro Nacional de Aceleradores (CNA), 41092 Sevilla, Spain; [email protected] (J.G.L.); [email protected] (A.G.O.) 2Departamento de Física Aplicada II, Universidad de Sevilla, 41012 Sevilla, Spain 3Departamento de Física Atómica, Molecular y Nuclear, Universidad de Sevilla, E-41080 Sevilla, Spain 4Instituto de Física de Cantabria (IFCA-UC-CSIC), 39005 Cantabria, Spain; [email protected] (I.V.); [email protected] (R.J.) 5Solid State Detector Group, CERN, CH-1211 Genéve 23, Switzerland; [email protected] 6Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Universitat Autònoma de Barcelona, 08193 Barcelona, Spain; salvador[email protected] (S.H.); [email protected] (G.P.) *Correspondence: [email protected] Abstract: Gain suppression induced by excess carriers in Low Gain Avalanche Detectors (LGADs) has been investigated using 3 MeV protons in a nuclear microprobe. In order to modify the ionization density inside the detector, Ion Beam Induced Current (IBIC) measurements were performed at different proton beam incidence angles between 0 ◦ and 85 ◦ . The experimental results have been analyzed as a function of the ionization density projected on the multiplication layer, finding that the increase of ionization density leads to greater gain suppression. For bias voltages close to the gain onset value, this decrease in gain results into a significant distortion of the transient current waveforms measured by the Time-Resolved IBIC (TRIBIC) technique due to a deficit in the secondary holes component. For angles of incidence such that the Bragg peak falls within the sensitive volume of the detector, the formation of microplasmas modifies the behavior of the gain curves, producing an abrupt decrease in gain as the angle increases. Keywords: LGAD; IBIC; TRIBIC; gain suppression; microplasma generation; Bragg peak 1. Introduction Low Gain Avalanche Detectors (LGADs) are n + -on-psilicon sensors with intrinsic gain [ 1 ]. This technology has been developed in the framework of the RD50 Collaboration [ 2 ] and is based on the standard Avalanche Photo Diodes (APD). The internal gain is achieved by implantation of a p + multiplication layer between the n + contact and the p substrate. When the detector is biased, in the multiplication layer, a very strong electric field is created which induces the avalanche multiplication—impact ionization—of the electrons passing through it, thus creating additional electron-hole pairs. The gain values presented by LGADs are moderate (10–50), without breakdown, and increase smoothly with the applied voltage when the sensor is reverse biased (working in linear mode before breakdown). These gains need not be as high as those of APD detectors (usually with gain values >100, working in Geiger mode after breakdown) because, for measuring high-energy charged particles, it is not a requirement to have such high signal amplifications as for measuring low energy signals, which is a typical application of APD detectors. The use of LGADs is foreseen in the Large Hadron Collider (LHC) upgrade in cases where, in addition to good spatial resolution, excellent temporal resolution is needed to correctly determine and assign traces where there are a large number of individual interaction vertices (pile-up). In the High Luminosity upgrade of the European Laboratory for Particle Physics (CERN—HL-LHC), the pile-up factor is expected to be four times Sensors 2022,22, 1080. https://doi.org/10.3390/s22031080 https://www.mdpi.com/journal/sensors Sensors 2022,22, 1080 2 of 17 higher than in the current LHC experiments [ 3 ]. Therefore, both ATLAS and CMS plan to introduce sub-detectors in order to perform timing measurements of Minimum Ionizing Particles (MIPs) [ 4 , 5 ] that will require timing capabilities of the order of ~30 ps. To this end, thin LGADs for the High Granularity Time Detector (HGTD) have been proposed as an option in ATLAS and, in CMS, this technology has been proposed for the MIP timing detector (MTD) [6,7]. Schematics of the cross-section of a standard LGAD and a twin PIN diode, along with the electric field profile in each case can be seen in Figure 1. Sensors 2022, 22, x FOR PEER REVIEW 2 of 17 Particle Physics (CERN—HL-LHC), the pile-up factor is expected to be four times higher than in the current LHC experiments [3]. Therefore, both ATLAS and CMS plan to introduce sub-detectors in order to perform timing measurements of Minimum Ionizing Particles (MIPs) [4,5] that will require timing capabilities of the order of ~30 ps. To this end, thin LGADs for the High Granularity Time Detector (HGTD) have been proposed as an option in ATLAS and, in CMS, this technology has been proposed for the MIP timing detector (MTD) [6,7]. Schematics of the cross-section of a standard LGAD and a twin PIN diode, along with the electric field profile in each case can be seen in Figure 1. Figure 1. (a) a schematic of the cross-section of a pad-like PIN detector and a qualitative profile of the electric field amplitude is shown. (b) a schematic of the cross-section of a pad-like LGAD and qualitative profile of the electric field amplitude is shown, there is a peak located in the same region of the gain layer in which the avalanche happens. To ensure a good interpretation of the data obtained in an experiment with LGADs, it is essential to know the gain value at all times, as gain variations during sensor operation can degrade the temporal resolution [8,9]. The gain is dependent on temperature and reverse bias voltage, and also changes when the detector is damaged if it is subjected to a high radiation field [9]. This is why it is necessary to keep the applied voltage and temperature well controlled during an experiment and to know how the gain versus voltage curves change as the detector is irradiated, i.e., when the fluence to which it is exposed increases. In this way, gain changes can be corrected by raising the applied voltage. Another effect that can induce gain suppression in LGADs is the formation of microplasmas in the bulk due to the generation of a high ionization density, i.e., a high carrier density along the particle’s track [10,11]. However, when the ionization trace is below the regime of microplasma formation, a decrease in detector gain was not expected. Contrary to this assumption, a recent study has shown that even the ionization density produced by a MIP when passing through an LGAD generates gain suppression, and this is because the electric field suffers a drop when the generated carriers reach the multiplication layer [12]. In that work, it is shown how the gain measured with an infrared (IR) laser and a Sr90 beta emitter differs at a given voltage. Although the IR-laser intensity was adjusted to generate the charge equivalent to that produced by a MIP (the electrons from the Sr-90 source), the ionization density generated by both probes is different due to the difference in the volume of the generated track, i.e., in the case of the Sr-90, the charge is generated in a much narrower ionizing path so the projection of the ionization density onto the multiplication layer is much larger. When a large density of carriers reaches the multiplication layer, there is a local drop in the electric field which causes the impact ionization parameter to decrease, resulting in a lower gain [13]. That research has shown that the comparison between gain curves obtained using different types of ionization sources is not adequate, since the gain does not depend only on the charge generated by the primary beam, (a) (b) Figure 1. ( a ) a schematic of the cross-section of a pad-like PIN detector and a qualitative profile of the electric field amplitude is shown. ( b ) a schematic of the cross-section of a pad-like LGAD and qualitative profile of the electric field amplitude is shown, there is a peak located in the same region of the gain layer in which the avalanche happens. To ensure a good interpretation of the data obtained in an experiment with LGADs, it is essential to know the gain value at all times, as gain variations during sensor operation can degrade the temporal resolution [ 8 , 9 ]. The gain is dependent on temperature and reverse bias voltage, and also changes when the detector is damaged if it is subjected to a high radiation field [ 9 ]. This is why it is necessary to keep the applied voltage and temperature well controlled during an experiment and to know how the gain versus voltage curves change as the detector is irradiated, i.e., when the fluence to which it is exposed increases. In this way, gain changes can be corrected by raising the applied voltage. Another effect that can induce gain suppression in LGADs is the formation of microplasmas in the bulk due to the generation of a high ionization density, i.e., a high carrier density along the particle’s track [10,11]. However, when the ionization trace is below the regime of microplasma formation, a decrease in detector gain was not expected. Contrary to this assumption, a recent study has shown that even the ionization density produced by a MIP when passing through an LGAD generates gain suppression, and this is because the electric field suffers a drop when the generated carriers reach the multiplication layer [ 12 ]. In that work, it is shown how the gain measured with an infrared (IR) laser and a Sr-90 beta emitter differs at a given voltage. Although the IR-laser intensity was adjusted to generate the charge equivalent to that produced by a MIP (the electrons from the Sr-90 source), the ionization density generated by both probes is different due to the difference in the volume of the generated track, i.e., in the case of the Sr-90, the charge is generated in a much narrower ionizing path so the projection of the ionization density onto the multiplication layer is much larger. When a large density of carriers reaches the multiplication layer, there is a local drop in the electric field which causes the impact ionization parameter to decrease, resulting in a lower gain [ 13 ]. That research has shown that the comparison between gain curves obtained using different types of ionization sources is not adequate, since the gain does not depend only on the charge generated by the primary beam, but also on the distribution of the ionization density generated, even when no microplasmas are generated. This makes knowing the ionization density when using LGADs a fundamental Sensors 2022,22, 1080 3 of 17 factor when interpreting the results obtained, as well as knowing the temperature, the applied voltage and the fluence at which they have been tested. In this work, Ion Beam Induced Charge (IBIC) and Time Resolved-IBIC (TRIBIC) measurements have been performed with 3 MeV protons to characterize a LGAD detector. The absolute gain curves obtained by IBIC and the one measured by Transient-Current Technique (TCT) with an IR-laser of equivalent intensity to approximately 20 MIPs differ significantly (Figure 2), implying that the gain suppression when using 3 MeV protons is important. Note that the protons used generate a charge equivalent to that of 75 MIPs and the trace volume is about 10 times smaller compared to a focused IR-laser (Figure 2), so in this case the ionization densities differ by about a factor 40. Sensors 2022, 22, x FOR PEER REVIEW 3 of 17 but also on the distribution of the ionization density generated, even when no microplasmas are generated. This makes knowing the ionization density when using LGADs a fundamental factor when interpreting the results obtained, as well as knowing the temperature, the applied voltage and the fluence at which they have been tested. In this work, Ion Beam Induced Charge (IBIC) and Time Resolved-IBIC (TRIBIC) measurements have been performed with 3 MeV protons to characterize a LGAD detector. The absolute gain curves obtained by IBIC and the one measured by Transient-Current Technique (TCT) with an IR-laser of equivalent intensity to approximately 20 MIPs differ significantly (Figure 2), implying that the gain suppression when using 3 MeV protons is important. Note that the protons used generate a charge equivalent to that of 75 MIPs and the trace volume is about 10 times smaller compared to a focused IR-laser (Figure 2), so in this case the ionization densities differ by about a factor 40. Figure 2. (a) LGAD structure and details of IBIC and TCT measurements (Al: aluminum layer; M: multiplication layer; figure not to scale). (b) Absolute gain curves obtained by IBIC and TCT with IR-laser. The objective of this work is to perform a detailed study of the dependence of the absolute gain on the projected ionization density in the gain layer (from now on, this quantity will be referred to as the linear ionisation density, λ). For this purpose, IBIC measurements were performed at different angles of incidence on twin PIN and LGAD detectors, differing only in the implantation of the gain layer in the later. The angular study of the PIN detector has made it possible to determine the structure of the detector, which has been fundamental to know with accuracy the energy deposited in the dead layers and in the bulk of the detectors. This information is crucial to calculate, for each angle, how many and where carriers have formed along the ion trajectory. Angle-dependent LGAD experiments (up to 50°) have established how the gain increases with decreasing λ-parameter, while measurements for larger angles (up to 85°) have resulted in a change of trend in the gain behavior upon entering the microplasma formation regime, as from a critical angle of 57° the Bragg peak is deposited within the active bulk. One advantage of the IBIC technique proposed in this study over the use of TCT-lasers or Sr-90 sources is its better spatial resolution. Furthermore, in comparison with the previous work [12], performed with a collimated Sr-90 source and where the maximum angle of rotation was limited to 14°, in our study we used a monoenergetic and focused ion beam, which allows to define more precisely the angle of incidence and to increase it up to 90° by rotating the sample in vacuum. 2. Experimental Details 2.1. LGADs The samples studied in this work are a PIN and a LGAD detector manufactured by the Centro Nacional de Microelectrónica (IMB-CNM-CSIC) [14]. Both detectors come from the same wafer and underwent the same fabrication process and are identical except for the p+ implant (gain layer) in the case of the LGAD. The samples were fabricated on a 347 (b) (a) Figure 2. ( a ) LGAD structure and details of IBIC and TCT measurements (Al: aluminum layer; M: multiplication layer; figure not to scale). ( b ) Absolute gain curves obtained by IBIC and TCT with IR-laser. The objective of this work is to perform a detailed study of the dependence of the absolute gain on the projected ionization density in the gain layer (from now on, this quantity will be referred to as the linear ionisation density, λ ). For this purpose, IBIC measurements were performed at different angles of incidence on twin PIN and LGAD detectors, differing only in the implantation of the gain layer in the later. The angular study of the PIN detector has made it possible to determine the structure of the detector, which has been fundamental to know with accuracy the energy deposited in the dead layers and in the bulk of the detectors. This information is crucial to calculate, for each angle, how many and where carriers have formed along the ion trajectory. Angle-dependent LGAD experiments (up to 50 ◦ ) have established how the gain increases with decreasing λ -parameter, while measurements for larger angles (up to 85 ◦ ) have resulted in a change of trend in the gain behavior upon entering the microplasma formation regime, as from a critical angle of 57 ◦ the Bragg peak is deposited within the active bulk. One advantage of the IBIC technique proposed in this study over the use of TCT-lasers or Sr-90 sources is its better spatial resolution. Furthermore, in comparison with the previous work [ 12 ], performed with a collimated Sr-90 source and where the maximum angle of rotation was limited to 14 ◦ , in our study we used a monoenergetic and focused ion beam, which allows to define more precisely the angle of incidence and to increase it up to 90 ◦ by rotating the sample in vacuum. 2. Experimental Details 2.1. LGADs The samples studied in this work are a PIN and a LGAD detector manufactured by the Centro Nacional de Microelectrónica (IMB-CNM-CSIC) [ 14 ]. Both detectors come from the same wafer and underwent the same fabrication process and are identical except for the p + implant (gain layer) in the case of the LGAD. The samples were fabricated on a 347 µ m thick Si-on-Si wafer, where a 50 µ m thick high-resistivity <100> FZ wafer is bonded to a low-resistivity, 300 µ m thick, <100> Czochralski wafer. The boron dose implanted, with an energy of 100 keV, to create the multiplication layer was 1.5 ×1013 at/cm2. Sensors 2022,22, 1080 4 of 17 The samples consist of a matrix of 2 × 2 pixel detectors with an area of 2.063 ×2.063 mm2 each. The four pixels of the matrix were connected via bond wires to four independent 50 Ω vias ending each one on an SMA connector used to output the signal and to bias the detector. The PCB was designed to be compatible with the TCT system at the CERN Solid State Detector (SSD) laboratory and the nuclear microprobe at the Centro Nacional de Aceleradores (CNA), where the IBIC measurements were carried out. Figure 3shows one of the detectors mounted on the PCB and placed in the sample holder of the CNA nuclear microprobe. A cross section of the LGAD diode is shown in Figure 4. Sensors 2022, 22, x FOR PEER REVIEW 4 of 17 µm thick Si-on-Si wafer, where a 50 µm thick high-resistivity <100> FZ wafer is bonded to a low-resistivity, 300 µm thick, <100> Czochralski wafer. The boron dose implanted, with an energy of 100 keV, to create the multiplication layer was 1.5 × 1013 at/cm2. The samples consist of a matrix of 2 × 2 pixel detectors with an area of 2.063 × 2.063 mm2 each. The four pixels of the matrix were connected via bond wires to four independent 50 Ω vias ending each one on an SMA connector used to output the signal and to bias the detector. The PCB was designed to be compatible with the TCT system at the CERN Solid State Detector (SSD) laboratory and the nuclear microprobe at the Centro Nacional de Aceleradores (CNA), where the IBIC measurements were carried out. Figure 3 shows one of the detectors mounted on the PCB and placed in the sample holder of the CNA nuclear microprobe. A cross section of the LGAD diode is shown in Figure 4. Figure 3. LGAD mounted in a dedicated PCB for IBIC, TRIBIC and TCT measurements installed in the sample holder of the CNA nuclear microprobe. On top of the detector there is an aluminum plate with scintillator materials, quartz and a copper grid for beam localization and focusing. Figure 4. Schematic cross section of the LGAD of 2 × 2 pixels from the CNM production run 10478. The electrical characterization (I-V, C-V) of the detectors was performed at the SSD lab at CERN. From the results, shown in Figure 5, the LGAD main parameters were extracted, these are: 𝑉𝑔𝑙~38 V, 𝑉𝑓𝑑~43 V, 𝑉𝑏𝑑~140 V (𝑉𝑔𝑙: Gain layer depletion voltage, 𝑉𝑓𝑑: Full depletion voltage, 𝑉𝑏𝑑: Breakdown voltage). The results shown in this paper correspond to a single pixel. Figure 3. LGAD mounted in a dedicated PCB for IBIC, TRIBIC and TCT measurements installed in the sample holder of the CNA nuclear microprobe. On top of the detector there is an aluminum plate with scintillator materials, quartz and a copper grid for beam localization and focusing. Sensors 2022, 22, x FOR PEER REVIEW 4 of 17 µm thick Si-on-Si wafer, where a 50 µm thick high-resistivity <100> FZ wafer is bonded to a low-resistivity, 300 µm thick, <100> Czochralski wafer. The boron dose implanted, with an energy of 100 keV, to create the multiplication layer was 1.5 × 1013 at/cm2. The samples consist of a matrix of 2 × 2 pixel detectors with an area of 2.063 × 2.063 mm2 each. The four pixels of the matrix were connected via bond wires to four independent 50 Ω vias ending each one on an SMA connector used to output the signal and to bias the detector. The PCB was designed to be compatible with the TCT system at the CERN Solid State Detector (SSD) laboratory and the nuclear microprobe at the Centro Nacional de Aceleradores (CNA), where the IBIC measurements were carried out. Figure 3 shows one of the detectors mounted on the PCB and placed in the sample holder of the CNA nuclear microprobe. A cross section of the LGAD diode is shown in Figure 4. Figure 3. LGAD mounted in a dedicated PCB for IBIC, TRIBIC and TCT measurements installed in the sample holder of the CNA nuclear microprobe. On top of the detector there is an aluminum plate with scintillator materials, quartz and a copper grid for beam localization and focusing. Figure 4. Schematic cross section of the LGAD of 2 × 2 pixels from the CNM production run 10478. The electrical characterization (I-V, C-V) of the detectors was performed at the SSD lab at CERN. From the results, shown in Figure 5, the LGAD main parameters were extracted, these are: 𝑉𝑔𝑙~38 V, 𝑉𝑓𝑑~43 V, 𝑉𝑏𝑑~140 V (𝑉𝑔𝑙: Gain layer depletion voltage, 𝑉𝑓𝑑: Full depletion voltage, 𝑉𝑏𝑑: Breakdown voltage). The results shown in this paper correspond to a single pixel. Figure 4. Schematic cross section of the LGAD of 2 ×2 pixels from the CNM production run 10478. The electrical characterization (I-V, C-V) of the detectors was performed at the SSD lab at CERN. From the results, shown in Figure 5, the LGAD main parameters were extracted, these are: V gl ~38 V, V fd ~43 V, V bd ~140 V (V gl : Gain layer depletion voltage, V fd : Full depletion voltage, V bd : Breakdown voltage). The results shown in this paper correspond to a single pixel. Sensors 2022,22, 1080 5 of 17 Sensors 2022, 22, x FOR PEER REVIEW 5 of 17 Figure 5. Electrical characterization of PIN and LGAD detectors: (a) I-V curves; (b) C-V curves. 2.2. Experimental Set-Up The IBIC and TRIBIC measurements were performed at the nuclear microprobe beamline of the CNA 3 MV tandem accelerator (Figure 6) [15]. The beam passes through a scanning coil which is the responsible of deflecting the ion beam to scan areas of a defined size. The standard OM-25 scanning coils are designed to operate with a quadrupole focusing system and MeV energy ions. The OM-150 coupled triplet is the element responsible of focusing the ion beam. It consists of a coupled triplet of OM-50 high precision magnetic quadrupole lenses in Convergent-Divergent-Convergent (CDC) configuration. At the end of the line is the OM-70 sample chamber. It is compatible with high vacuum. Inside the chamber, there is an X-ray SiLi detector, a Si detector for charged particles measurements and a microscope for sample and beam observation. The TCT with infrared laser (IR) results were obtained at the SSD of the EP-DT group at CERN by the Instituto de Física de Cantabria (IFCA) Particle Physics and Instrumentation (PP&I) group. Detailed information on this set-up can be found in [12]. The fundamentals of both techniques are similar: a probe (laser pulse in TCT and protons, or another ion, in IBIC) generates an ionization trace through the detector and the carriers created in the active volume of the sensor move towards the electrodes by the effect of the electric field, inducing a current pulse that is processed by the electronic chain. Note that, in both cases, the total charge generated within the detector will be proportional to the energy deposited in it, the proportionality factor being the product 𝑔 × 1/𝜀 × 𝑞, where 𝑔 is the gain of the detector, 𝜀 = 3.62 eV is the mean energy required to produce an electron-hole pair in silicon and 𝑞 = 1.6 × 10−19 𝐶 is the elemental charge. In the case of the TRIBIC technique, the current signal induced in the electrodes is brought to the input of an oscilloscope either directly or after passing through a current amplifier with a high bandwidth so as not to change the shape of the signal. Thus, we can measure the temporal evolution of the induced signal, not only the total charge generated as in the IBIC technique. (a) (b) (a) (b) Figure 5. Electrical characterization of PIN and LGAD detectors: (a) I-V curves; (b) C-V curves. 2.2. Experimental Set-Up The IBIC and TRIBIC measurements were performed at the nuclear microprobe beamline of the CNA 3 MV tandem accelerator (Figure 6) [ 15 ]. The beam passes through a scanning coil which is the responsible of deflecting the ion beam to scan areas of a defined size. The standard OM-25 scanning coils are designed to operate with a quadrupole focusing system and MeV energy ions. The OM-150 coupled triplet is the element responsible of focusing the ion beam. It consists of a coupled triplet of OM-50 high precision magnetic quadrupole lenses in Convergent-Divergent-Convergent (CDC) configuration. At the end of the line is the OM-70 sample chamber. It is compatible with high vacuum. Inside the chamber, there is an X-ray SiLi detector, a Si detector for charged particles measurements and a microscope for sample and beam observation. The TCT with infrared laser (IR) results were obtained at the SSD of the EP-DT group at CERN by the Instituto de Física de Cantabria (IFCA) Particle Physics and Instrumentation (PP&I) group. Detailed information on this set-up can be found in [12]. Sensors 2022, 22, x FOR PEER REVIEW 5 of 17 Figure 5. Electrical characterization of PIN and LGAD detectors: (a) I-V curves; (b) C-V curves. 2.2. Experimental Set-Up The IBIC and TRIBIC measurements were performed at the nuclear microprobe beamline of the CNA 3 MV tandem accelerator (Figure 6) [15]. The beam passes through a scanning coil which is the responsible of deflecting the ion beam to scan areas of a defined size. The standard OM-25 scanning coils are designed to operate with a quadrupole focusing system and MeV energy ions. The OM-150 coupled triplet is the element responsible of focusing the ion beam. It consists of a coupled triplet of OM-50 high precision magnetic quadrupole lenses in Convergent-Divergent-Convergent (CDC) configuration. At the end of the line is the OM-70 sample chamber. It is compatible with high vacuum. Inside the chamber, there is an X-ray SiLi detector, a Si detector for charged particles measurements and a microscope for sample and beam observation. The TCT with infrared laser (IR) results were obtained at the SSD of the EP-DT group at CERN by the Instituto de Física de Cantabria (IFCA) Particle Physics and Instrumentation (PP&I) group. Detailed information on this set-up can be found in [12]. The fundamentals of both techniques are similar: a probe (laser pulse in TCT and protons, or another ion, in IBIC) generates an ionization trace through the detector and the carriers created in the active volume of the sensor move towards the electrodes by the effect of the electric field, inducing a current pulse that is processed by the electronic chain. Note that, in both cases, the total charge generated within the detector will be proportional to the energy deposited in it, the proportionality factor being the product 𝑔 × 1/𝜀 × 𝑞, where 𝑔 is the gain of the detector, 𝜀 = 3.62 eV is the mean energy required to produce an electron-hole pair in silicon and 𝑞 = 1.6 × 10−19 𝐶 is the elemental charge. In the case of the TRIBIC technique, the current signal induced in the electrodes is brought to the input of an oscilloscope either directly or after passing through a current amplifier with a high bandwidth so as not to change the shape of the signal. Thus, we can measure the temporal evolution of the induced signal, not only the total charge generated as in the IBIC technique. (a) (b) (a) (b) Figure 6. ( a ) Main elements of the microbeam system at CNA. ( b ) Zenithal image of the vacuum chamber into which the samples are inserted. The fundamentals of both techniques are similar: a probe (laser pulse in TCT and protons, or another ion, in IBIC) generates an ionization trace through the detector and the carriers created in the active volume of the sensor move towards the electrodes by the effect of the electric field, inducing a current pulse that is processed by the electronic chain. Note that, in both cases, the total charge generated within the detector will be proportional to the energy deposited in it, the proportionality factor being the product g× 1 /ε×q , where g is the gain of the detector, ε= 3.62 eV is the mean energy required to produce an electron-hole pair in silicon and q= 1.6 × 10 −19 C is the elemental charge. In the case of the TRIBIC technique, the current signal induced in the electrodes is brought to the input of an oscilloscope either directly or after passing through a current amplifier with a high bandwidth so as not to change the shape of the signal. Thus, we can measure the temporal evolution of the induced signal, not only the total charge generated as in the IBIC technique. Sensors 2022,22, 1080 6 of 17 The IBIC and TRIBIC studies were accomplished with a 3 MeV proton beam with count rate of a few tens of particles per second and performing a scan of 100 × 100 µ m 2 to avoid damage to the detectors during the measurements. For IBIC, the signal height was recorded as a function of the applied reverse bias voltage using a Canberra 2003BT preamplifier, a Tennelec TC245 amplifier with a shaping time of 1 µ s and the OMDAQ ADC/MCA system from Oxford Microbeams [ 16 ]. The TRIBIC experiments were performed by connecting the detector signal directly to a Cividec C2 current amplifier (2 GHz, 40 dB) and the output of this amplifier to the 50 Ω input of a high bandwidth oscilloscope TeledyneLecroy HDO9404 (4 GHz, 40 GS/s), where 1000 signals were recorded and averaged to improve the signal-to-noise ratio. For angular measurements, a special sample holder was used which allows the sensor to be rotated completely in vacuum, i.e., from 0 ◦ to 360 ◦ , with an accuracy of 1 ◦ . Results up to 85 ◦ will be presented. All measurements in this work have been made at room temperature (~20 ◦C). 3. Results and Discussion 3.1. Detector Homogeneity and Structure Before proceeding with the angular measurements, a study of the homogeneity of the Charge Collection Efficiency (CCE) along the surface of the detectors was performed. This preliminary step is necessary because, although the area scanned by the beam in the gain measurements (100 × 100 µ m 2 ) is small compared to the dimensions of the detectors (2 × 2 mm 2 ), when working with grazing angles the beam projection in one direction is somewhat larger than 1 mm. For homogeneity measurements the beam was focused to a size of 3 µ m and a 2.5 × 2.5 mm 2 scan was performed covering the entire surface of the detectors. Figure 7shows the weighted mean CCE maps (normalized to 1) for PIN (left) and LGAD (right) obtained with the detectors biased to 43 V. Sensors 2022, 22, x FOR PEER REVIEW 6 of 17 Figure 6. (a) Main elements of the microbeam system at CNA. (b) Zenithal image of the vacuum chamber into which the samples are inserted. The IBIC and TRIBIC studies were accomplished with a 3 MeV proton beam with count rate of a few tens of particles per second and performing a scan of 100 × 100 µm2 to avoid damage to the detectors during the measurements. For IBIC, the signal height was recorded as a function of the applied reverse bias voltage using a Canberra 2003BT preamplifier, a Tennelec TC245 amplifier with a shaping time of 1 μs and the OMDAQ ADC/MCA system from Oxford Microbeams [16]. The TRIBIC experiments were performed by connecting the detector signal directly to a Cividec C2 current amplifier (2 GHz, 40 dB) and the output of this amplifier to the 50 Ω input of a high bandwidth oscilloscope TeledyneLecroy HDO9404 (4 GHz, 40 GS/s), where 1000 signals were recorded and averaged to improve the signal-to-noise ratio. For angular measurements, a special sample holder was used which allows the sensor to be rotated completely in vacuum, i.e., from 0° to 360°, with an accuracy of 1°. Results up to 85° will be presented. All measurements in this work have been made at room temperature (~20 °C). 3. Results and Discussion 3.1. Detector Homogeneity and Structure Before proceeding with the angular measurements, a study of the homogeneity of the Charge Collection Efficiency (CCE) along the surface of the detectors was performed. This preliminary step is necessary because, although the area scanned by the beam in the gain measurements (100 × 100 μm2) is small compared to the dimensions of the detectors (2 × 2 mm2), when working with grazing angles the beam projection in one direction is somewhat larger than 1 mm. For homogeneity measurements the beam was focused to a size of 3 μm and a 2.5 × 2.5 mm2 scan was performed covering the entire surface of the detectors. Figure 7 shows the weighted mean CCE maps (normalized to 1) for PIN (left) and LGAD (right) obtained with the detectors biased to 43 V. Quantitative results indicate that the homogeneity of the CCE is better than 2% in the PIN and 4% in the LGAD. The line crossing both detectors correspond to the electrical bonding, since the protons passing through it reach the detector with a lower energy and, therefore, create a higher number of carriers in the active volume (CCE > 1) due to the increase of the stopping power at lower energies. In the case of the LGAD, a drop in the CCE is also observed at the periphery of the detector, which corresponds to the end of the multiplication layer. Figure 7. Weighted mean CCE maps (normalized to 1) for the PIN (a) and LGAD (b). (a) (b) Figure 7. Weighted mean CCE maps (normalized to 1) for the PIN (a) and LGAD (b). Quantitative results indicate that the homogeneity of the CCE is better than 2% in the PIN and 4% in the LGAD. The line crossing both detectors correspond to the electrical bonding, since the protons passing through it reach the detector with a lower energy and, therefore, create a higher number of carriers in the active volume (CCE > 1) due to the increase of the stopping power at lower energies. In the case of the LGAD, a drop in the CCE is also observed at the periphery of the detector, which corresponds to the end of the multiplication layer. Although the structure of the detectors is perfectly determined from the manufacturing processes, the thicknesses of the various passivation and metallization layers as well as the thickness of the active zone are not known with sufficient precision. This data is however necessary for a correct interpretation of the results obtained with the LGAD. To accurately determine the structure of the detector, a series of IBIC measurements at different angles of Sensors 2022,22, 1080 7 of 17 incidence were carried out on the PIN detector, which is identical to the LGAD except for the multiplication layer. Figure 8shows the energy spectra (in normalized counts versus channel) obtained at different angles. On Figure 8a are the spectra measured up to 55 ◦ , where, for these conditions, all protons pass completely through the detector. As it can be seen, as the angle is increased, the peaks move towards higher channels, i.e., higher energies, which is due to a higher energy deposition in the detector due to the longer trajectory of the proton inside the sensor’s active volume. The spectra also become wider for larger angles due to the increased energy straggling. From the displacement of these peaks, the thickness of the active zone of the detector was obtained. Figure 8b shows the spectra for larger angles, between 60–85 ◦ . Under these conditions, all the protons stop in the sensitive volume of the detector, so the straggling decreases and at 70 ◦ we have a much thinner peak than at 50 ◦ , but the peaks broaden again when the energy lost in the dead layers of the detector becomes non-negligible, causing the peaks at 80 ◦ and 85 ◦ broaden again. In addition, as more energy is deposited in the dead layers, the energy deposited in the active volume is less, so these peaks shift to lower channels i.e., lower energies. In this case, the displacement of these peaks was used to determine the thickness of the dead layers of the detector, which for simplicity we have considered as an equivalent thickness of the Al electrode. Sensors 2022, 22, x FOR PEER REVIEW 7 of 17 Although the structure of the detectors is perfectly determined from the manufacturing processes, the thicknesses of the various passivation and metallization layers as well as the thickness of the active zone are not known with sufficient precision. This data is however necessary for a correct interpretation of the results obtained with the LGAD. To accurately determine the structure of the detector, a series of IBIC measurements at different angles of incidence were carried out on the PIN detector, which is identical to the LGAD except for the multiplication layer. Figure 8 shows the energy spectra (in normalized counts versus channel) obtained at different angles. On Figure 8a are the spectra measured up to 55°, where, for these conditions, all protons pass completely through the detector. As it can be seen, as the angle is increased, the peaks move towards higher channels, i.e., higher energies, which is due to a higher energy deposition in the detector due to the longer trajectory of the proton inside the sensor’s active volume. The spectra also become wider for larger angles due to the increased energy straggling. From the displacement of these peaks, the thickness of the active zone of the detector was obtained. Figure 8b shows the spectra for larger angles, between 60–85°. Under these conditions, all the protons stop in the sensitive volume of the detector, so the straggling decreases and at 70° we have a much thinner peak than at 50°, but the peaks broaden again when the energy lost in the dead layers of the detector becomes non-negligible, causing the peaks at 80° and 85° broaden again. In addition, as more energy is deposited in the dead layers, the energy deposited in the active volume is less, so these peaks shift to lower channels i.e., lower energies. In this case, the displacement of these peaks was used to determine the thickness of the dead layers of the detector, which for simplicity we have considered as an equivalent thickness of the Al electrode. Figure 8. IBIC spectra from PIN diode in counts vs channel. (a): measurements up to 55° from which the thickness of the active layer is obtained. (b): the spectra for 60°, 70°, 80° and 85° from which the thickness of the dead layers (Al equivalent) is extracted. Using SRIM2013 software [17], simulations of energy loss in the Al and Si layers have been performed for all angles of incidence. The energy loss in the other two passive layers, the oxide and passivation, will translate into an overestimation of the thickness of the Al layer, keeping the energy deposition (and thus, charge) and thickness estimation for the silicon active volume still valid. By means of an iterative process, the thicknesses of both layers have been adjusted to obtain the best fitting calibration line for all experimental data (simulated deposited energy in Si vs centroid of the peaks). The values obtained, 1.5 µm Al and 48 µm Si, agree with those supplied by the IMB-CNM group (1.5 µm Al and 44 µm active volume + 4 µm multiplication layer [14]). Through this iterative process, the calibration curve of the Multichannel Analyzer was also found (as shown in Figure 9). Figure 8. IBIC spectra from PIN diode in counts vs channel. ( a ): measurements up to 55 ◦ from which the thickness of the active layer is obtained. ( b ): the spectra for 60 ◦ , 70 ◦ , 80 ◦ and 85 ◦ from which the thickness of the dead layers (Al equivalent) is extracted. Using SRIM2013 software [ 17 ], simulations of energy loss in the Al and Si layers have been performed for all angles of incidence. The energy loss in the other two passive layers, the oxide and passivation, will translate into an overestimation of the thickness of the Al layer, keeping the energy deposition (and thus, charge) and thickness estimation for the silicon active volume still valid. By means of an iterative process, the thicknesses of both layers have been adjusted to obtain the best fitting calibration line for all experimental data (simulated deposited energy in Si vs centroid of the peaks). The values obtained, 1.5 µ m Al and 48 µ m Si, agree with those supplied by the IMB-CNM group (1.5 µ m Al and 44 µm active volume + 4 µm multiplication layer [14]). Through this iterative process, the calibration curve of the Multichannel Analyzer was also found (as shown in Figure 9). Sensors 2022,22, 1080 8 of 17 Sensors 2022, 22, x FOR PEER REVIEW 8 of 17 Figure 9. MCA calibration curve obtained by plotting the most probable value of the deposited energies at different angles simulated by the SRIM 2013 code against the experimental channels and calculating the line of best fit. 3.2. Absolute Gain Curves in the Microplasma-Free Regime Absolute gain curves were obtained by measuring the LGAD and PIN detectors under the same conditions, so that all parameters that vary with beam incidence angle, such as energy deposition in the sensitive volume, cancel out. The absolute gain was calculated as the ratio between the energy measured with the LGAD and the energy measured with the PIN detector, which is equivalent to the ratio between the charges collected at each of the detectors. The TRIBIC waveforms obtained from the PIN detector from 0° to 50° (Figure 10a) also served to ensure that, despite the increase in deposited energy with angle, in this range of values there is no formation of microplasmas in the detector volume, since otherwise the current pulse shapes would exhibit a slow component in their rise time attributed to the dispersal of the plasma [18]. Furthermore, the IBIC measurement at normal incidence of the PIN diode for all applied bias voltages up to 130 V (Figure 10b) showed no displacement of the peak, i.e., the collected charge was the same, which indicates that there are no diffusion effects due to the charge deposited on the electro neutral substrate under the active layer, so that the effects observed in the gain curves, must be related to the quenching of impact ionization due only to changes in the linear ionization density. Figure 10. PIN measurements. (a) TRIBIC waveforms normalised to total deposited charge from 0° to 50°. (b) IBIC spectra in the bias voltage range 10–130 V. Figure 9. MCA calibration curve obtained by plotting the most probable value of the deposited energies at different angles simulated by the SRIM 2013 code against the experimental channels and calculating the line of best fit. 3.2. Absolute Gain Curves in the Microplasma-Free Regime Absolute gain curves were obtained by measuring the LGAD and PIN detectors under the same conditions, so that all parameters that vary with beam incidence angle, such as energy deposition in the sensitive volume, cancel out. The absolute gain was calculated as the ratio between the energy measured with the LGAD and the energy measured with the PIN detector, which is equivalent to the ratio between the charges collected at each of the detectors. The TRIBIC waveforms obtained from the PIN detector from 0 ◦ to 50 ◦ (Figure 10a) also served to ensure that, despite the increase in deposited energy with angle, in this range of values there is no formation of microplasmas in the detector volume, since otherwise the current pulse shapes would exhibit a slow component in their rise time attributed to the dispersal of the plasma [ 18 ]. Furthermore, the IBIC measurement at normal incidence of the PIN diode for all applied bias voltages up to 130 V (Figure 10b) showed no displacement of the peak, i.e., the collected charge was the same, which indicates that there are no diffusion effects due to the charge deposited on the electro neutral substrate under the active layer, so that the effects observed in the gain curves, must be related to the quenching of impact ionization due only to changes in the linear ionization density. Sensors 2022, 22, x FOR PEER REVIEW 8 of 17 Figure 9. MCA calibration curve obtained by plotting the most probable value of the deposited energies at different angles simulated by the SRIM 2013 code against the experimental channels and calculating the line of best fit. 3.2. Absolute Gain Curves in the Microplasma-Free Regime Absolute gain curves were obtained by measuring the LGAD and PIN detectors under the same conditions, so that all parameters that vary with beam incidence angle, such as energy deposition in the sensitive volume, cancel out. The absolute gain was calculated as the ratio between the energy measured with the LGAD and the energy measured with the PIN detector, which is equivalent to the ratio between the charges collected at each of the detectors. The TRIBIC waveforms obtained from the PIN detector from 0° to 50° (Figure 10a) also served to ensure that, despite the increase in deposited energy with angle, in this range of values there is no formation of microplasmas in the detector volume, since otherwise the current pulse shapes would exhibit a slow component in their rise time attributed to the dispersal of the plasma [18]. Furthermore, the IBIC measurement at normal incidence of the PIN diode for all applied bias voltages up to 130 V (Figure 10b) showed no displacement of the peak, i.e., the collected charge was the same, which indicates that there are no diffusion effects due to the charge deposited on the electro neutral substrate under the active layer, so that the effects observed in the gain curves, must be related to the quenching of impact ionization due only to changes in the linear ionization density. Figure 10. PIN measurements. (a) TRIBIC waveforms normalised to total deposited charge from 0° to 50°. (b) IBIC spectra in the bias voltage range 10–130 V. Figure 10. PIN measurements. ( a ) TRIBIC waveforms normalised to total deposited charge from 0 ◦ to 50◦. (b) IBIC spectra in the bias voltage range 10–130 V. Sensors 2022,22, 1080 9 of 17 The absolute gain results obtained in this microplasma-free regime are shown in Figure 11. The curve exhibits the lowest gain values for normal incidence (0 ◦ ) and rises progressively as the angle of incidence increases until reaching the maximum value at 50 ◦ . Sensors 2022, 22, x FOR PEER REVIEW 9 of 17 The absolute gain results obtained in this microplasma-free regime are shown in Figure 11. The curve exhibits the lowest gain values for normal incidence (0°) and rises progressively as the angle of incidence increases until reaching the maximum value at 50°. Figure 11. Absolute gain curves for angles of incidence from 0° to 50°. The SRIM simulations depicted in Figure 12a demonstrate that, although the energy deposited by the proton beam (ΔE) increases with angle, the projection of the ionization trace onto the multiplication layer grows much larger, making the linear ionization density a decreasing function with angle. It is important to note that since the ionization profile is depth-dependent, the λ-parameter will have different values along the X-axis projection, as shown in the SRIM simulation in Figure 12b. The mean value of the λ-profile (mean linear ionisation density) versus the absolute gain is plotted in Figure 12c. At 130 V, the absolute gain increases by approximately 45% when the detector is rotated by 50°. (a) Figure 11. Absolute gain curves for angles of incidence from 0◦to 50◦. The SRIM simulations depicted in Figure 12a demonstrate that, although the energy deposited by the proton beam ( ∆ E) increases with angle, the projection of the ionization trace onto the multiplication layer grows much larger, making the linear ionization density a decreasing function with angle. It is important to note that since the ionization profile is depth-dependent, the λ -parameter will have different values along the X-axis projection, as shown in the SRIM simulation in Figure 12b. The mean value of the λ -profile (mean linear ionisation density) versus the absolute gain is plotted in Figure 12c. At 130 V, the absolute gain increases by approximately 45% when the detector is rotated by 50◦. Sensors 2022, 22, x FOR PEER REVIEW 9 of 17 The absolute gain results obtained in this microplasma-free regime are shown in Figure 11. The curve exhibits the lowest gain values for normal incidence (0°) and rises progressively as the angle of incidence increases until reaching the maximum value at 50°. Figure 11. Absolute gain curves for angles of incidence from 0° to 50°. The SRIM simulations depicted in Figure 12a demonstrate that, although the energy deposited by the proton beam (ΔE) increases with angle, the projection of the ionization trace onto the multiplication layer grows much larger, making the linear ionization density a decreasing function with angle. It is important to note that since the ionization profile is depth-dependent, the λ-parameter will have different values along the X-axis projection, as shown in the SRIM simulation in Figure 12b. The mean value of the λ-profile (mean linear ionisation density) versus the absolute gain is plotted in Figure 12c. At 130 V, the absolute gain increases by approximately 45% when the detector is rotated by 50°. (a) Figure 12. ( a ) SRIM simulations of the energy deposited by a 3 MeV proton beam entering from the top with an incident angle of 0 ◦ , 30 ◦ and 50 ◦ . The red dashed line indicates the end of the active layer. ( b ) Profile of the ionization density projected on the x axis for angles up to 50 ◦ . ( c ) Absolute gain versus the mean linear ionisation density at 130 V. Sensors 2022,22, 1080 16 of 17 Abbreviations Acronym Definition ADC Analog-to-Digital Converter APD Avalanche Photo Diode ATLAS A Toroidal Large hadron collider ApparatuS CCE Charge Collection Efficiency CERN Conseil Européen pour la Recherche Nucléaire CMS Compact Muon Solenoid CNA Centro Nacional de Aceleradores CNM Centro Nacional de Microelectrónica CSIC Consejo Superior de Investigaciones Científicas EP-DT Experimental Physics—Detector Technologies HGTD High Granularity Time Detector IBIC Ion Beam Induced Current IFCA Instituto de Física de Cantabria IMB Instituto de Microelectrónica de Barcelona IR InfraRed LGAD Low Gain Avalanche Detector LHC Large Hadron Collider MCA MultiChannel Analyzer MIP Minimum Ionizing Particle MTD Minimum ionizing particle Timing Detector PIN p-type—Intrinsic—n-type PP&I Particle Physics and Instrumentation SMA SubMiniature version A SSD Solid State Detector TCT Transient Current Technique TPA Two Photon Absorption TRIBIC Time-Resolved Ion Beam Induced Current US Universidad de Sevilla λLinear ionization density References 1. Pellegrini, G.; Fernández-Martínez, P.; Baselga, M.; Fleta, C.; Flores, D.; Greco, V.; Hidalgo, S.; Mandi´c, I.; Kramberger, G.; Quirion, D.; et al . Technology developments and first measurements of low gain avalanche detectors (LGAD) for high energy physics applications. Nucl. Instrum. Methods A 2014,765, 12–16. [CrossRef] 2. RD50’s Webpage. Available online: https://rd50.web.cern.ch/ (accessed on 25 January 2022). 3. Aberle, O.; Alonso, B.; Brüning, O.; Fessia, P.; Rossi, L.; Tavian, L.; Zerlauth, M.; Adorisio, C.; Adraktas, A.; Ady, M.; et al. High-Luminosity Large Hadron Collider (HL-LHC) Technical Design Report V. 0.1; CERN: Geneva, Switzerland, 2017. [CrossRef] 4. Technical Proposal for a MIP Timing Detector in the CMS Experiment Phase 2 Upgrade; Technical Report CERN-LHCC-2017-027. LHCC-P-009; CERN: Geneva, Switzerland, December 2017; Available online: https://cds.cern.ch/record/2296612 (accessed on 25 January 2022). 5. Technical Proposal: A High-Granularity Timing Detector for the ATLAS Phase-II Upgrade; Technical Report CERN-LHCC-2018-023. LHCC-P-012; CERN: Geneva, Switzerland, June 2018; Available online: https://cds.cern.ch/record/2623663CERN-ACC-2018-0 05 (accessed on 15 November 2021). 6. RD50 Prolongation Request: May 2018. Available online: https://cds.cern.ch/record/2320882/files/LHCC-SR-007.pdf (accessed on 25 January 2022). 7. Currás, E. Low Gain Avalanche Detectors for 4-dimensional Tracking Applications in Severe Radiation Environments. In Proceedings of the 29th International Workshop on Vertex Detectors (VERTEX2020), Shonan, Japan, 4–9 October 2020; p. 010015. 8. Sadrozinski, H.F.; Seiden, A.; Cartiglia, N. 4D tracking with ultra-fast silicon detectors. Rep. Prog. Phys. 2017 ,81, 026101. [CrossRef] [PubMed] 9. Ferrero, M.; Arcidiacono, R.; Barozzi, M.; Boscardin, M.; Cartiglia, N.; Dalla Betta, G.F.; Galloway, Z.; Mandurrino, M.; Mazza, S.; Paternoster, G.; et al. Radiation resistant LGAD design. Nucl. Instrum. Methods A 2019,919, 16–26. [CrossRef] 10. Miller, G.L.; Brown, W.L.; Donovan, P.F.; Mackintosh, I.M. Silicon p-n junction radiation detectors. IRE Trans. Nucl. Sci. 1960 ,7, 185–189. [CrossRef] 11. Laird, J.S.; Onoda, S.; Hirao, T.; Edmonds, L. Quenching of impact ionization in heavy-ion induced electronhole pair plasma tracks in wide bandwidth avalanche photodetectors. J. Appl. Phys. 2010,107, 084501. [CrossRef] Sensors 2022,22, 1080 17 of 17 12. Currás, E.; Fernández, M.; Moll, M. Gain suppression mechanism observed in Low Gain Avalanche Detectors. arXiv 2021 , arXiv:2107.10022. 13. Maes, W.; De Meyer, K.; Van Overstraeten, R. Impact ionization in silicon: A review and update. Solid-State Electron. 1990 ,33, 705–718. [CrossRef] 14. Carulla, M.; Doblas, A.; Flores, D.; Galloway, Z.; Hidalgo, S.; Kramberger, G.; Luce, Z.; Mandic, I.; Mazza, S.; Merlos, A.; et al. 50 µ m thin Low Gain Avalanche Detectors (LGAD) for timing applications. Nucl. Instrum. Methods A 2019 ,924, 373–379. [CrossRef] 15. Gómez-Camacho, J.; López, J.G.; Guerrero, C.; Gutiérrez, J.L.; García-Tenorio, R.; Santos-Arévalo, F.J.; Chamizo, E.; Ferrer, F.J.; Jiménez-Ramos, M.C.; Balcerzyk, M.; et al. Research facilities and highlights at the Centro Nacional de Aceleradores (CNA). Eur. J. Plus 2021,136, 273. [CrossRef] 16. Grime, G.W.; Dawson, M.; Marsh, M.A.; McArthur, I.C.; Watt, F. Oxford Scanning Proton Microprobe Facility. Nucl. Instrum. Methods B 1991,54, 52–63. [CrossRef] 17. SRIM2013. Available online: http://www.srim.org/ (accessed on 25 January 2022). 18. Williams, R.N.; Lawson, E.M. The plasma effect in silicon semiconductor radiation detectors. Nucl. Instrum. Methods 1974 ,120, 261–268. [CrossRef] 19. Cartiglia, N.; Arcidiacono, R.; Baselga, M.; Bellan, R.; Boscardin, M.; Cenna, F.; Spencer, N. Design optimization of ultra-fast silicon detectors. Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrometers Detect. Assoc. Equip. 2015 ,796, 141–148. [CrossRef] 20. Tove, P.A.; Seibt, W. Plasma effects in semiconductor detectors. Nucl. Instrum. Methods A 1999,30, 100–109. [CrossRef] 21. Mouskeftaras, A.; Chanal, M.; Chambonneau, M.; Clady, R.; Utéza, O.; Grojo, D. Direct measurement of ambipolar diffusion in bulk silicon by ultrafast infrared imaging of laser-induced microplasmas. Appl. Phys. Lett. 2016,108, 041107. [CrossRef] 22. Nakhostin, M. Signal Processing for Radiation Detectors; John Willey & Sons: Hoboken, NJ, USA, 2018.